Technical data (for applications outside these parameters,please consult us!) | |||
General | |||
Weight | -DBE and DBEM | kg | 6.0 |
-DBEE and DBEME | kg | 6.2 | |
Installation orientation | Optional | ||
Storage temperature range | ℃ | -20 to+80 | |
Ambient temperature | -DBE and DBEM | ℃ | -20 to+70 |
range | -DBEE and DBEME | ℃ | -20 to+50 |
Hydraulic(measured with HLP46;70oil=40℃±5℃ and p=100 bar) | |||
Max.operating pressure | -Ports A,B and X | bar | 350 |
-Port Y | Separately and at zero pressure to tank | ||
Max.set pressure | -Pressure stage 50 bar | bar | 50 |
-Pressure stage 100 bar | bar | 100 | |
-Pressure stage 200 bar | bar | 200 | |
-Pressure stage 315 bar | bar | 315 | |
-Pressure stage 350 bar | bar | 350 | |
Min.set pressure in port A with zero command value | bar | See characteristic curve on page 7 | |
Maximum pressure relief function (infinitely adjustable) | -Pressure stage 50 bar | bar | Pressure adjustment range:Factory setting: |
30 to 70 70 bar | |||
-Pressure stage 100 bar | bar | 50 to 130 130 bar | |
-Pressure stage 200 bar | bar | 90 to 230 230 bar | |
-Pressure stage 315 bar | bar | 150 to 350 350 bar | |
-Pressure stage 350 bar | bar | 200 to 390 390 bar | |
Max.flow | L/min | 600 | |
Pilot flow | L/min | 0.7 to 2 | |
Hydraulic fluid | Mineral oil(HL,HLP)to DIN 51524. | ||
Other hydraulic fluids on enquiry! | |||
Hydraulic fluid temperature range | ℃ | -20 to+80 | |
Viscosity range | mm²/s | 15 to 380 | |
Max.permissible degree of contamination of the hy- | Class 20/18/151) | ||
draulic fluid -cleanliness class to ISO 4406(c) | |||
Hysteresis(see comm.value/pressure characteristic curve on page 7) | % | ±1.5 of max.set pressure | |
Repeatability | % | <±2 of max.set pressure | |
Linearity | % | ±3.5 of max.set pressure | |
Tolerance of the command | -DBE and DBEM | % | ±2.5 of max.set pressure |
value/pressure curve | -DBEE and DBEME | % | ±1.5 of max.set pressure |
referred to hysteresis curve,increasing pressure | |||
Step response T+T | 0→100% | ms | 150 Depending on flow and on line volume |
100→0% | ms | 150 in port A of the system |