When two sections of a hydraulic tandem pump lose performance together, a shared charge supply is a useful diagnostic branch, but it is not proof that the charge pump has failed. Confirm the circuit first, then compare common supply pressure, branch delivery and the conditions under which each loop becomes weak. One leaking or incorrectly controlled branch can consume shared charge capacity and affect the other section. Conversely, a restriction after the common gallery can leave one loop healthy and the other under-supplied. The correct approach distinguishes common causes from local demand before replacing either main pump section.
Confirm what is actually shared
Tandem describes a mechanical arrangement, not a complete charge-circuit specification. Two pump sections may have independent main working ports while receiving charge oil from a common source. Other installations can use external charge supply, separate sources or additional valves that alter the relationship. The complete hydraulic schematic determines which branches share pressure, flow and filtration.
The Danfoss H1T reference manual illustrates two main pump sections with a charge circuit and documents integral and external charge configurations. It is useful for understanding the distinction between independent working loops and common support functions. Its port names, pressure settings and internal routing are not specifications for a Prance pump or for an arbitrary tandem assembly.
Charge pressure and charge capacity answer different questions
Charge pressure shows whether a measurement point is maintaining pressure under the tested condition. Charge capacity concerns whether enough flow remains available for loop replenishment, control demand and other documented consumers. A satisfactory neutral pressure reading does not prove sufficient supply during simultaneous demand or after the oil reaches operating temperature.
A shared supply can remain regulated while excess capacity exists, then lose pressure when combined demand exceeds available delivery. That loss can arise from reduced source delivery, an inlet restriction, excessive leakage or an unintended consumer. Increasing a relief setting does not identify which branch changed. Establish both the operating condition and the location of the pressure measurement.
Use symptom patterns to choose the next measurement
| Symptom pattern | Useful common branch | Useful local branch | Next evidence needed |
|---|---|---|---|
| Both sections weak even in neutral checks | Source delivery, inlet path or common pressure regulation | A large downstream loss affecting the common gallery | Common supply pressure, case pressure and circuit routing |
| One section weak while the other remains normal | Shared reserve may still be adequate | Local check valve, control supply or loop leakage | Branch and loop measurements at matching conditions |
| Each works alone but both weaken together | Combined demand versus available charge delivery | One branch consuming excessive flow only when loaded | Approved simultaneous-demand test and source assessment |
| Performance deteriorates as oil warms | Temperature-dependent supply or leakage | Leakage in an individual loop or consumer | Matched warm readings rather than cold-only comparison |
| Both stop after a control-enable change | Shared control-supply or enable logic | Direction-specific control faults still possible | Electrical permission and pressure at the documented control feed |
This is a qualitative fault-isolation table. Its basis is the H1T circuit and troubleshooting material plus the transmission-circuit recommendations linked below. It contains no universal charge-pressure setting. Carry out measurements only through the machine manufacturer’s approved procedure and correctly rated test points.
Establish a safe baseline without isolating random lines
Identify both main loops, the charge source, filtration path, relief return and control consumers on the drawing. Include any flushing, brake-release or auxiliary branch actually present. A hose entering the center section is not enough to determine its function. Trace port designations against the correct assembly drawing before connecting instruments.
Inspect oil level, visible leakage, connector retention and filter service information with the machine isolated. If contamination, a damaged hose or a low reservoir condition is found, resolve it before running an extended test. Do not cap a case drain, block a relief path or disconnect a charge line to see which section improves. Such changes can remove lubrication, overpressure a housing or release stored energy.
For a powered test, use trained personnel, approved restraints, rated instruments and the specified operating sequence. Stop if unexpected motion, severe noise, rapid heating or a pressure excursion occurs. A general diagnostic article cannot define safe load fixtures or instrumentation for an unidentified transmission. Follow the manufacturer’s pressure-release procedure before moving any connection.
Compare readings under matched conditions
Record shaft speed, oil temperature, commanded state and load for each observation. Compare section one alone, section two alone and combined demand only where the approved procedure permits those states. A difference taken at another speed or oil condition can be mistaken for a branch fault when source delivery has changed.
Measure at the specified common and local points. Pressure upstream of a filter does not establish pressure at a control or loop branch downstream. Likewise, a control-feed measurement does not necessarily establish low-side loop replenishment. The pressure drop between identified locations can localize a restriction, but the acceptable drop and test flow must come from the installed documentation.
Check the pressure reference. Some charge-relief specifications are referenced to case pressure, so gauge pressure alone can be misleading when case pressure changes. As an arithmetic example, 24 bar supply gauge pressure and 4 bar case gauge pressure give a 20 bar differential. These are assumed values only, not acceptable limits for a Prance pump. The subtraction is valid only for simultaneous readings with the same reference.
Interpret a fault that affects both sections
When common pressure is low at the documented supply point in every permitted state, investigate the common path before treating two main pump sections as independently failed. Relevant branches can include reservoir supply, inlet restriction, charge-pump drive and condition, filtration and pressure regulation. A shared control cutoff can also interrupt control availability without proving failure of the main rotating groups.
However, a common low reading does not clear the downstream consumers. A stuck valve or excessive leakage in one branch can depressurize the shared gallery. Determine whether the low pressure begins with a particular command or load. Then use the manufacturer’s approved flow or leakage assessment to distinguish inadequate source delivery from excess consumption. Do not replace the charge pump solely because the common pressure is low.
If both sections have adequate charge pressure but poor main-loop performance, revisit the meaning of the measurement. Check whether the controls receive the required supply and command, and whether pressure or power controls are intervening. Shared shaft-speed or drive problems can affect both outputs without being a charge fault. Keep the evidence attached to the actual circuit function.
Interpret a fault that follows only one branch
If one section remains healthy under matching conditions, a fully common source failure becomes less likely but is not excluded. The healthy section may require less make-up flow or operate at a different load. Compare demands rather than assuming equal section size creates equal charge consumption. Motor leakage, flushing and control use can differ between otherwise similar drive paths.
A local restriction or faulty charge check can prevent delivery into one low-pressure loop while the gallery remains regulated. A control fault can instead reduce displacement and resemble weak pumping. Use separate evidence for local charge availability, control response and main-loop pressure. One pressure gauge at the charge source cannot distinguish all three.
Do not infer which component is defective from case-drain temperature or flow without knowing the drain arrangement. A combined drain can contain leakage, relief discharge and flushing flow from several sources. It may help evaluate total heat or return demand but cannot automatically assign leakage to one rotating group. Use the documented separation and measurement procedure rather than disconnecting return hoses experimentally.

Use real product photographs within their limits
Prance’s AA4VG page supplies a relevant closed-circuit variable pump family and original product views for configuration discussions. The photographs used here identify that family; they do not depict the H1T reference tandem assembly or prove that an AA4VG order shares a particular charge gallery. A tandem installation requires confirmation of the complete assembly and circuit.
For a configuration review, provide both pump-section identifications, the source of charge oil and the machine schematic. State whether the complaint affects one section, both independently or only simultaneous operation. Include the measurement locations and conditions. That information separates a shared-supply sizing enquiry from a local control or leakage fault without inventing internal features from the housing appearance.

Verify the repair against the original demand
After an identified fault is corrected, repeat the original approved comparison rather than checking only idle pressure. Verify the permitted individual and combined demand states at the required oil condition. Confirm control response, charge availability and main-loop behavior, and inspect for leaks after returning all test connections to their documented state.
If contamination caused a valve or filter problem, follow the machine’s cleaning and fluid-service instructions before declaring the repair complete. A replaced component can be damaged again if the source remains. Confirm filter indication and cooling performance through the specified checks, without raising relief settings to disguise pressure loss or temperature rise.
The acceptance result should show why the shared source is adequate and why each branch receives what it requires. If one branch remains unexplained, keep it open as a separate fault rather than compensating elsewhere. The goal is a reproducible diagnosis of the support circuit and the individual loops, not merely a temporary improvement in machine speed.
Preguntas frecuentes
¿Cada bomba tándem tiene una bomba de carga?
No. Tandem identifies coupled pump sections, while charge architecture depends on the complete design. Integral, external and separate supply arrangements are possible. Use the installed schematic and full order identification to establish which sections and consumers actually share the source.
¿Puede un bucle defectuoso debilitar al otro bucle?
Yes, where both depend on a common supply and one branch consumes enough flow to reduce shared availability. That is a possible mechanism, not a diagnosis from symptoms alone. Compare common pressure and branch behavior under the approved individual and combined demand conditions.
¿Es suficiente la presión de carga neutra normal para despejar el suministro?
No. The source may maintain pressure at low demand but become inadequate during combined operation or at another oil temperature. Verify the documented demand states and the pressure at the relevant branch, not only at an upstream gallery or idle condition.
¿Debería aumentar la presión de carga cuando ambas secciones son débiles?
Do not adjust it without identifying the cause and the correct specification. A higher setting can conceal a restriction or excess consumption and add heat. Confirm source delivery, reference pressure and downstream demand before using the exact manufacturer’s approved adjustment procedure.
¿Qué información hace que una consulta sea útil?
Provide both pump codes, the charge-source arrangement, circuit drawing, symptom pattern and measurements with locations, speed, temperature and command state. Original photographs help identify components, but they cannot establish internal routing or substitute for the complete assembly documentation.
Recursos relacionados de productos e ingeniería
AA4VG Closed Circuit Variable Piston Pump, gama de productos de bombas hidráulicas, Presión de carga en circuito cerrado: qué suministra y cómo diagnosticar la pérdida, Tandem Pump Flow Priority: Keeping Steering Supplied Under Load. Confirmar el código completo del producto y los requisitos de aplicación al solicitar una revisión de configuración.
Referencias técnicas
- Danfoss H1T service manual: reference control and measurement architecture, not AA4VG specifications
- Danfoss: Transmission Circuit Recommendations, reference bypass and charge circuit principles
- NIOSH: Preventing Deaths from Uncontrolled Hazardous Energy
Aprendizaje adicional: bombas hidráulicas
3.2 – Bombas Hidráulicas por NPTEL-NOC IITM proporciona antecedentes sobre los principios de operación de bombas. Los fundamentos de la bomba proporcionan antecedentes sobre desplazamiento y transferencia de energía; la conferencia no demuestra el procedimiento de diagnóstico o instalación específico discutido aquí. Complementa los fundamentos de los componentes; no es un procedimiento de prueba para el circuito completo discutido anteriormente.