AA4VG Closed Circuit Variable Piston Pump

The AA4VG pump is offered for closed-circuit hydrostatic drives with integrated auxiliary oil supply. Its AA4VG code and interface data must be checked independently when comparing an A4VG configuration, even where nominal displacement appears similar.

  • Integrated auxiliary supply
  • Flow reverses through neutral
  • Adjustable pressure cut-off
  • Through-drive configuration requires matching

PRANCE HYDRAULIC · PRODUCT SERIES

AA4VG Closed Circuit Variable Piston Pump

Axial piston; variable swashplate · Closed circuit

The AA4VG pump is offered for closed-circuit hydrostatic drives with integrated auxiliary oil supply. Its AA4VG code and interface data must be checked independently when comparing an A4VG configuration, even where nominal displacement appears similar.

Model

✓AA4VG original product photograph
AA4VGAxial piston; variable swashplate
Request a QuotationVer Datos Técnicos y Ficha Técnica

Confirm the complete model and approved specification with Prance Hydraulic. Product-series references alone do not establish interchangeability.

Configuration review · Technical documentation · Product selection

Detalles del producto

  • Integrated auxiliary supply
  • Flow reverses through neutral
  • Adjustable pressure cut-off
  • Through-drive configuration requires matching

CATEGORIES: Bomba de pistón, Bomba de desplazamiento variable

AA4VG Features & Application

Integrated auxiliary supply

Account for pilot or replenishment demand and the relevant pressure limits. Include filtration and the return or drain route in the circuit review.

Flow reverses through neutral

Review combined drive torque and simultaneous demand, including any additional pump connected to the drive.

Adjustable pressure cut-off

Keep continuous, intermittent and peak conditions separate. Use the row for the selected size and configuration.

Through-drive configuration requires matching

Review combined drive torque and simultaneous demand, including any additional pump connected to the drive.

AA4VG Specifications

Series / modelAA4VG
Product typeAA4VG Closed Circuit Variable Piston Pump
DiseñoAxial piston; variable swashplate
Circuit / selectionClosed circuit
Published nominal sizes28, 40, 56, 71, 90 and 125
CircuitoClosed circuit; verify charge and control requirements

AA4VG Selection & Configuration

The AA4VG pump is offered for closed-circuit hydrostatic drives with integrated auxiliary oil supply. Its AA4VG code and interface data must be checked independently when comparing an A4VG configuration, even where nominal displacement appears similar.

Provide the complete machine loop, charge requirements and control specification. Confirm shaft and port standards, pressure cut-off settings and the torque capacity of any through-drive assembly before approving a replacement.

AA4VG original product view

cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits.
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits.

Hydraulic pumps · Hydraulic motors · Hydraulic valves

Send the MS nameplate, operating requirements and installation drawing for a configuration review before quoting.

  • Model review — send the full model code or an existing nameplate photograph.
  • Interface matching — confirm shaft, mounting flange, rotation and ports.
  • Operating conditions — provide flow, pressure, speed, fluid and duty cycle.
  • Documentation — request the relevant product data and drawings for your review.
Prance workshop with a row of production equipment

AA4VG Buying Guide

Use this sequence to prepare the AA4VG configuration for review and quotation.

  1. Define required flow at the actual drive speed and continuous pressure.
  2. Identify peak pressure, duration and the work cycle.
  3. Confirm the selected displacement control and any auxiliary-drive requirement.
  4. Match rotation viewed from the shaft end, shaft, flange and ports.
  5. Review inlet conditions, drain routing and the installation envelope.
  6. Confirm fluid, viscosity, temperature, filtration and seals.
  7. Approve the complete model, control, drawing, quantity and delivery terms.
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits

Selection, Documentation & Project Support

Prance technical team image from its company website

Selection Support

Learn more →

Share your hydraulic circuit, operating point and installation requirements for a configuration discussion.


Flow · Pressure · Speed · Interfaces
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits

Technical Resources

Learn more →

Review product documentation, model codes and technical data before finalizing the specification.


Datasheets · Model codes · Drawings
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits

Project Inquiries

Learn more →

Send your required model, quantity, application and project requirements to discuss your inquiry.


Product inquiries · Configuration review

Configuration, Quantity & Delivery

Confirm the complete MS code, approved drawing and operating limits. Availability, quantity, documentation and delivery date are confirmed in the quotation.

Discuss Your AA4VG Application

Send the full model code, operating duty, installation details and quantity.

Request a AA4VG Quotation

AA4VG Questions Before Ordering

What type of product is the AA4VG?

AA4VG Closed Circuit Variable Piston Pump. Design: Axial piston; variable swashplate. Closed circuit. Confirm the complete order code for the offered version.

Can a similar pump replace the AA4VG?

cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits.

cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits

Define required flow at the actual drive speed and continuous pressure. Identify peak pressure, duration and the work cycle. Attach the nameplate, complete order code, installation drawing and required quantity.

AA4VG Technical Data & Documents

View AA4VG catalog data and operating conditions

cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits.

Datos técnicos

Tamaño NG 28 40 56 71 90 125
Desplazamiento geométrico por revolución Vabuelitax   en3 1.71 2.44 3.42 4.33 5.49 7.63
bomba de caudal variable cm3 28 40 56 71 90 125
bomba de refuerzo (a p = 290 psi (20 bar)) Vg Español   en3 0.37 0.52 0.71 1.20 1.20 1.73
cm3 6.1 8.6 11.6 19.6 19.6 28.3
Velocidad de rotación1) máximo en VG máximo nNombre rpm 4250 4000 3600 3300 3050 2950
limitado, máximo2) nmax1 rpm 4500 4200 3900 3600 3300 3250
intermitente, máximo3) nmax2 rpm 5000 5000 4500 4100 3800 3450
mínimo nmín rpm 500 500 500 500 500 500
Flujo en yNombre y VG máximo qv gpm 31.4 42.3 53.4 61.8 72.6 94
l/min 119 160 202 234 275 356
Poder4) en yNombre, VG máximo y Δp = 5800 psi P hp 106 143 180 209 245 319
Δp = 400 bar P kW 79 107 134 156 183 238
Par de torsión4) a las VG máximo y Δp = 5800 psi T lb-pie 131 188 263 333 423 587
Δp = 400 bar T Nm 178 255 357 452 573 796
Ap = 1450 psi T libras-pie 33 47 66 83 105 147
Ap = 100 bar T Nm 45 64 89 113 143 199
Rigidez a la torsión del eje de transmisión S c lb-ft/rad 23159 50892 59595 72871 116609 161010
kNm/rad 31.4 69 80.8 98.8 158.1 218.3
T c lb-ft/rad – – 70068 89171 – 185939
kNm/rad – – 95 120.9 – 252.1
U c lb-ft/rad – 37468 – – 79362 –
kNm/rad – 50.8 – – 107.6 –
Momento de inercia para el grupo rotativo JTW libras-pie2 0.0522 0.0902 0.1566 0.2302 0.3536 0.5505
kgm2 0.0022 0.0038 0.0066 0.0097 0.0149 0.0232
Aceleración angular máxima5) α rad/s2 38000 30000 24000 21000 18000 14000
Volumen de casos V chica 0.24 0.29 0.40 0.34 0.40 0.55
I 0.9 1.1 1.5 1.3 1.5 2.1
Peso (sin toma de fuerza) aprox. m SIID 64 68 84 110 132 176
Kg 29 31 38 50 60 80

Aviso

▶Theoretical values, without efficiency and tolerances;values rounded ▶Operation above the maximum values or below the minimum values may result in a loss of function,a reduced service life or in the destruction of the axial piston unit. Prance recommends testing the loads by means of experiment or calculation /simulation and comparison with the permissible values.

Determinación de las características de funcionamiento

Clave

Vg  Desplazamiento por revolución [en3(cm3)] Δp  Differential pressure [psi(bar)] n   Rotational speed [rpm] ηv   Volumetric efficiency ηhm  Hydraulic-mechanical efficiency ηt   Eficiencia total (ηt= ηv*ηhm) 1)The values are applicable: – for the optimum viscosity range from Vopt = 170 to 82 SUS(36 to 16 mm2/s) – for hydraulic fluid based on mineral oils (for HF hydraulic fluids,observe the technical data in 90225) 2)Valid at half corner power (e.g. at VG máximo y pN/2) 3) Valid at Δp = 1000 to 2200 psi (70 to 150 bar) or Δp < 4350 psi(300 bar) and t < 0.1 s 4)Without boost pump 5)The data are valid for values between the minimum required and maximum permissible rotational speed. Valid for external excitation (e.g. diesel engine 2 to 8 times rotary frequency, cardan shaft twice the rotary frequency). The limit value is only valid for a single pump. The load capacity of the connecting parts must be considered.

Fuerzas radiales y axiales admisibles en el eje de transmisión

▼Eje ranurado ANSI B92.1a
Tamaño NG 28 40 40 56 56 71
Árbol de transmisión en 1 1 1 1/4 1 1/4 1 3/8 1 1/4
Fuerza radial máxima a una distancia a (desde el collarín del eje) cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits Fq máx libra 671 958 766 1073 975 1360
N 2983 4261 3409 4772 4338 6050
a en 0.75 0.75 0.94 0.94 0.94 0.94
mm 19 19 24 24 24 24
Fuerza axial máxima cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits +Fax max libra 350 477 477 654 654 954
N 1557 2120 2120 2910 2910 4242
-Fax max libra 94 198 198 355 355 620
N 417 880 880 1490 1490 2758
Tamaño NG 71 90 90 125 125
Árbol de transmisión en 1 3/8 1 1/4 1 3/4 1 3/4 2
Fuerza radial máxima a una distancia a (desde el collarín del eje) cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits Fq máx libra 1236 1724 1232 1711 1497
N 550 7670 5478 7609 6658
a en 0.94 0.94 1.32 1.32 1.57
mm 24 24 33.5 33.5 40
Fuerza axial máxima cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits +Fax max libra 954 973 973 1361 1361
N 4242 4330 4330 6053 6053
-Fax max libra 620 600 600 797 797
N 2758 2670 2670 3547 3547

Aviso

▶The axial and radial forces generally influence the service life of the bearings. ▶Special requirements apply in the case of belt drive and cardan shaft. Please contact u
Tamaño NG 28 40 56 71 90 125
Par a Vg máx y Δp = 5800 psi1) T libras-pie 131 188 263 333 423 587
Δp = 400 bar1) T Nm 178 255 357 452 573 796
Maximum input torque at drive shaft2) ANSI B92.1a (SAE J744) S TE máx libras-pie 232 444 444 444 1210 1210
Nm 314 602 602 602 1640 1640
en 1 1 1/4 1 1/4 1 1/4 1 3/4 1 3/4
T TE máx libras-pie – – 715 715 – 1969
Nm – – 970 970 – 2670
en – – 1 3/8 1 3/8 – 2
U3) TE máx libras-pie – 232 – – 444 –
Nm – 314 – – 602 –
en – 1 – – 1 1/4 –
Par máximo de transmisión continua4) TD máx libras-pie 170 232 384 487 606 819
Nm 231 314 521 660 822 1110

Distribución de pares

cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits
Par de entrada TE=T1+T2+T3
TE < TE máx
Par de apriete a través del eje TD=T2+T3
TD < TD máx
1) Efficiency not considered 2) For drive shafts free of radial force 3) Shaft “U” is only permitted as drive shaft on the 2nd pump on a combination pump of the same size. 4)Note maximum input torque for shaft S!

Request a AA4VG Quotation

Tell us your required configuration, quantity and application.

Demostración de formulario de contacto
AA4VG original product photograph

Escribe código

01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22
AA4V G D / 32 - N

Unidad de pistones axiales

01 Diseño de plato oscilante, variable, presión nominal 5800 psi (400 bar), presión máxima 6500 psi (450 bar) AA4V

Modo de operación

02 Bomba, circuito cerrado G

Tamaño (NG)

03 Desplazamiento geométrico, véase "Datos técnicos" en la página 8 in3/rev. 1.71 2.44 3.42 4.33 5.49 7.63
cm³/rev. 28 40 56 71 90 125

Dispositivo de control

28 40 56 71 90 125
04 Sin módulo de control ● ● ● ● ● ● NV
Control proporcional, hidráulico Presión relacionada con el piloto p = 87 a 260 psi (6 a 18 bar) ○ ○ ● ● ● ● HD3
Servomecánico ● ● ● ● ● ● HW
Control proporcional, eléctrico U=12V ● ● ● ● ● ● EP3
U=24V ● ● ● ● ● ● EP4
Control de dos puntos, eléctrico U=12V ● ● ● ● ● ● EZ1
U=24V ● ● ● ● ● ● EZ2
Control automático, relacionado con la velocidad U=12V ● ● ● ● ● ● DA1
U=24V ● ● ● ● ● ● DA2
Control hidráulico, de acción directa ○ ○ ● ● ● ● DG
Control eléctrico, de operación directa,

dos válvulas reductoras de presión

U=12V ● ● ● ● - - ET5
U=24V ● ● ● ● - - ET6

Corte por presión

05 Corte por presión (estándar) D

Interruptor de posición neutral

06 Sin interruptor de posición neutral (sin código) ●
Interruptor de posición neutral (solo para control de hardware) ● L

Limitador de carrera mecánico

07 Sin limitador de carrera mecánico (sin código) ●
Limitador de carrera mecánico, ajustable externamente ● M

Puerto de presión de la cámara de carrera

28 40 56 71 90 125
08 Sin accionar el puerto de presión de la cámara X3, X4 (sin código) ● ● ● ● ● ●
Puerto de presión de la cámara de carrera X3, X4 ○ ○ ● ● ● ● T

Válvula de control DA

NV HD HW DG DA EP Fácil
09 Sin válvula de control DA ● ● ● ● - ● ● 1
válvula de control DA, ajuste fijo ● ● ● ● ● - 2
Válvula de control DA, ajustable mecánicamente con palanca de posición sentido de accionamiento, en sentido horario - ● ● ● ● ● - 3R
dirección de accionamiento,

en sentido contrario a las agujas del reloj

- ● ● ● ● ● - 3L
Válvula de control DA, ajuste fijo, conexiones para dispositivo de control piloto - ○ ○ - ○ ○ - 7
Válvula de control DA, ajuste fijo y

válula de aproximación de freno montada, control con líquido de frenos

a base de aceite mineral - - - - ● - - 8

•= disponible ○= bajo pedido -= no disponible       = programa preferido

Series

10 Serie 3, índice 2 32

Sentido de giro

11 Visto en el árbol de transmisión en el sentido de las agujas del reloj R
en sentido contrario a las agujas del reloj L

Material de sellado

12 NBR (caucho de nitrilo), retén de eje en FKM (fluoroelastómero) N

Árbol de transmisión

28 40 56 71 90 125
13 Eje ranurado

ANSIB92.1a

para bomba única ● ● ● ● ● ● S
para bomba de combinación - 1.ª bomba _1) _1) ● ● _1) ● T
solo para bomba de combinación - 2ª bomba - ● - - ● - U

Brida de montaje

28 40 56 71 90 125
14 SAEJ744 de 2 agujeros ● ● ● - - - C
de 2+4 orificios - - - ● ● ● F

Puerto de trabajo

28 40 56 71 90 125
15 Puerto de trabajo SAE A y B, superior e inferior Puerto de succión S inferior - ● ● ● ● ● 52
Puerto de trabajo SAE A y B, superior e inferior Puerto de succión S superior - ○ ● - - ○ 53
Puerto de trabajo SAE A y B, mismo lado derecho2) Puerto de succión S inferior ● - - - - - 60
Puerto de trabajo SAE A y B, mismo lado izquierdo2) Puerto de succión S inferior - - - ● - -
Puerto de trabajo SAE A y B, mismo lado derecho2) Puerto de succión S superior - - - - - ○ 63

Impulso bomba

16 Sin bomba de refuerzo integrada sin unidad de paso N
con transmisión directa K
Bomba de refuerzo integrada con y sin paso directo F

A través de unidades3)

28 40 56 71 90 125
17 Sin accionamiento pasante, versiones N y e F (núm. 16) únicamente ● ● ● ● ● ● 00
Brida SAE J7444) Cubo para eje ranurado
82-2 (A) 5/8 en 9T 16/32DP5) ● ● ● ● ● ● 01
101-2 (B) 7/8 de pulgada a 13 dientes 16/32 DP5) ● ● ● ● ● ● 02
1in 15T 16/32DP5) ● ● ● ● ● ● 04
127-2 (C)6) 1 1/4 in 14T 12/24DP5) - - ● ● ● ● 07
152-2/4 (D) 13/4 en 13T 8/16DP5) - - - - - ● 69

•= disponible ○= bajo pedido -= no disponible     = programa preferido

 1) Norma para bomba combinada - 1ª bomba: Eje S

2) Solo es posible sin el filtro de archivos adjuntos

3) Especificaciones para la versión con bomba de refuerzo integrada, por favor contáctenos para la versión sin bomba de refuerzo

4) 2 = 2 agujeros; 4 = 4 agujeros

5) Cubo para eje ranurado según ANSI B92.1a

6) NG90 a 125 con brida adicional de 4 agujeros (127-4)

Válvula de alivio de alta presión

Ajuste del rango Δp 28 40 56 71 90 125
18 Válvula de alivio de alta presión, operada por piloto de 1450 a 6100 psi

(100 a 420 bar)

con bypass - - - ● ● ● 1
Válvula de alivio de alta presión, de acción directa,

configuración fija

3600 a 6100 psi

(de 250 a 420 bar)

sin desvío ● ● ● - - - 3
con bypass ● ● ● - - - 4
1450 a 3600 bar

(100 a 250 bar)

sin desvío ● ● ● - - - 5
con bypass ● ● ● - - - 6

Circuito de refuerzo de filtración / suministro de presión de refuerzo externa

28 40 56 71 90 125
19 Filtración en la línea de succión de la bomba de refuerzo ● ● ● ● ● ● S
Filtración en la línea de presión de la bomba de refuerzo

Puertos para la filtración de circuitos de refuerzo externo (Fe y Fa)

● ● ● ● ● ● D
Válvula de arranque en frío montada y puertos para filtración de circuito de sobrealimentación externo - ● ● - - - K
Filtro de acoplamiento con válvula de arranque en frío - ● ● ● ● ● F
Filtro de acoplamiento con válvula de arranque en frío e indicador visual de contaminación - ● ● ● ● ● P
Filtro acoplado con válvula de arranque en frío e indicador eléctrico de contaminación - ● ● ● ● ● B
Suministro de presión de sobrealimentación externa (versión sin bomba de sobrealimentación integrada - NO0, K...) ● ● ● ● ● ● E

Sensor de ángulo de giro

28 40 56 71 90 125
20 Sin sensor de ángulo de giro (sin código) ● ● ● ● ● ●
Sensor de ángulo de giro eléctrico7) ○ ○ ● ○ ○ ○ R

Conector para solenoides8)

21 Sin conector (sin código), solo para control puramente hidráulico ●
conector moldeado DEUTSCH, de 2 pines sin diodo de supresión ● P
con diodo de supresión (solo para EZ y DA) ● Q

Versión estándar / especial

22 Versión estándar sin código
en combinación con una pieza de acoplamiento o una bomba de acoplamiento -K
Versión especial -S
en combinación con una pieza de acoplamiento o una bomba de acoplamiento -SK

•= disponible ○= bajo pedido -= no disponible      = programa preferido

Aviso

▶Tenga en cuenta las notas de planificación del proyecto en la página 68.

▶Además del código de tipo, especifique los datos técnicos pertinentes al realizar su pedido.

7) Por favor, póngase en contacto con nosotros si el sensor de ángulo de giro se utiliza para el control

8) Los conectores para otros componentes eléctricos pueden diferir

Datos técnicos

Tamaño NG 28 40 56 71 90 125
Desplazamiento geométrico por revolución Vabuelitax

 

en3 1.71 2.44 3.42 4.33 5.49 7.63
bomba de caudal variable cm3 28 40 56 71 90 125
bomba de refuerzo (a p = 290 psi (20 bar)) Vg Español

 

en3 0.37 0.52 0.71 1.20 1.20 1.73
cm3 6.1 8.6 11.6 19.6 19.6 28.3
Velocidad de rotación1) máximo en VG máximo nNombre rpm 4250 4000 3600 3300 3050 2950
limitado, máximo2) nmax1 rpm 4500 4200 3900 3600 3300 3250
intermitente, máximo3) nmax2 rpm 5000 5000 4500 4100 3800 3450
mínimo nmín rpm 500 500 500 500 500 500
Flujo en yNombre y VG máximo qv gpm 31.4 42.3 53.4 61.8 72.6 94
l/min 119 160 202 234 275 356
Poder4) en yNombre, VG máximo y Δp = 5800 psi P hp 106 143 180 209 245 319
Δp = 400 bar P kW 79 107 134 156 183 238
Par de torsión4) a las VG máximo y Δp = 5800 psi T lb-pie 131 188 263 333 423 587
Δp = 400 bar T Nm 178 255 357 452 573 796
Ap = 1450 psi T libras-pie 33 47 66 83 105 147
Ap = 100 bar T Nm 45 64 89 113 143 199
Rigidez a la torsión del eje de transmisión S c lb-ft/rad 23159 50892 59595 72871 116609 161010
kNm/rad 31.4 69 80.8 98.8 158.1 218.3
T c lb-ft/rad - - 70068 89171 - 185939
kNm/rad - - 95 120.9 - 252.1
U c lb-ft/rad - 37468 - - 79362 -
kNm/rad - 50.8 - - 107.6 -
Momento de inercia para el grupo rotativo JTW libras-pie2 0.0522 0.0902 0.1566 0.2302 0.3536 0.5505
kgm2 0.0022 0.0038 0.0066 0.0097 0.0149 0.0232
Aceleración angular máxima5) α rad/s2 38000 30000 24000 21000 18000 14000
Volumen de casos V chica 0.24 0.29 0.40 0.34 0.40 0.55
I 0.9 1.1 1.5 1.3 1.5 2.1
Peso (sin toma de fuerza) aprox. m SIID 64 68 84 110 132 176
Kg 29 31 38 50 60 80

Aviso

▶Valores teóricos, sin eficiencia ni tolerancias; valores redondeados

▶El funcionamiento por encima de los valores máximos o por debajo de los valores mínimos puede provocar una pérdida de función, una vida útil reducida o la destrucción de la unidad de pistones axiales. Bosch Rexroth recomienda comprobar las cargas mediante experimentos o cálculo / simulación y compararlas con los valores admisibles.

Determinación de las características de funcionamiento

Flujo qv=(Vg ∙ n ∙ ηv) /231 gpm (Vg ∙ n ∙ ηv) / 1000 l/min
Par de torsión T=(Vg ∙ Δp) /(24 ∙ π ∙ ηhm) libras-pie (Vg ∙ Δp) /(24 ∙ π ∙ ηhm) Nm
Poder P=(2π ∙ T ∙ n)/33000=(qv ∙ Δp)/(1714 ∙ ηt) HP (2π ∙ M ∙ n)/60000 = qv ∙ Δp∙ ηt)/600 kW

Clave

Vg  Desplazamiento por revolución [en3(cm3)]

Δp Presión diferencial [psi(bar)]

n   Velocidad de giro [rpm]

ηv   Eficiencia volumétrica

ηhm  Rendimiento hidráulico-mecánico

ηt   Eficiencia total (ηt= ηv*ηhm)

1) Los valores son aplicables:

- para el rango de viscosidad óptima de Vopt = 170 a 82 SUS (36 a 16 mm2/s)

- para fluidos hidráulicos a base de aceites minerales (para fluidos hidráulicos HF, observe los datos técnicos en 90225)

2) Válido a media potencia de esquina (p. ej., a VG máximo y pN/2)

3) Válido a Δp = 1000 a 2200 psi (70 a 150 bar) o Δp < 4350 psi (300 bar) y t < 0,1 s

4) Sin bomba de refuerzo

Los datos son válidos para valores comprendidos entre la velocidad de giro mínima requerida y la máxima admisible.

Válido para excitación externa (p. ej., motor diésel de 2 a 8 veces la frecuencia de giro, árbol cardán dos veces la frecuencia de giro).

El valor límite solo es válido para una sola bomba.

Se debe considerar la capacidad de carga de las piezas de unión.

Fuerzas radiales y axiales admisibles en el eje de transmisión

▼Eje ranurado ANSI B92.1a

Tamaño NG 28 40 40 56 56 71
Árbol de transmisión en 1 1 1 1/4 1 1/4 1 3/8 1 1/4
Fuerza radial máxima a una distancia a (desde el collarín del eje) Fq máx libra 671 958 766 1073 975 1360
N 2983 4261 3409 4772 4338 6050
a en 0.75 0.75 0.94 0.94 0.94 0.94
mm 19 19 24 24 24 24
Fuerza axial máxima +Fax max libra 350 477 477 654 654 954
N 1557 2120 2120 2910 2910 4242
-Fax max libra 94 198 198 355 355 620
N 417 880 880 1490 1490 2758
Tamaño NG 71 90 90 125 125
Árbol de transmisión en 1 3/8 1 1/4 1 3/4 1 3/4 2
Fuerza radial máxima a una distancia a (desde el collarín del eje) Fq máx libra 1236 1724 1232 1711 1497
N 550 7670 5478 7609 6658
a en 0.94 0.94 1.32 1.32 1.57
mm 24 24 33.5 33.5 40
Fuerza axial máxima +Fax max libra 954 973 973 1361 1361
N 4242 4330 4330 6053 6053
-Fax max libra 620 600 600 797 797
N 2758 2670 2670 3547 3547

Aviso

Las fuerzas axiales y radiales influyen generalmente en la vida útil de los rodamientos.

▶ Se aplican requisitos especiales en el caso de la transmisión por correa y el árbol cardán. Por favor, póngase en contacto con nosotros.

Tamaño NG 28 40 56 71 90 125
Par a Vg máx y Δp = 5800 psi1) T libras-pie 131 188 263 333 423 587
Δp = 400 bar1) T Nm 178 255 357 452 573 796
Par de entrada máximo

en el eje de transmisión2)

ANSI B92.1a (SAE J744)

S TE máx libras-pie 232 444 444 444 1210 1210
Nm 314 602 602 602 1640 1640
en 1 1 1/4 1 1/4 1 1/4 1 3/4 1 3/4
T TE máx libras-pie - - 715 715 - 1969
Nm - - 970 970 - 2670
en - - 1 3/8 1 3/8 - 2
U3) TE máx libras-pie - 232 - - 444 -
Nm - 314 - - 602 -
en - 1 - - 1 1/4 -
Par máximo de transmisión continua4) TD máx libras-pie 170 232 384 487 606 819
Nm 231 314 521 660 822 1110

Distribución de pares

Par en la 1.ª bomba T1
Par en la segunda bomba T2
Par en la tercera bomba T3
Par de entrada TE=T1+T2+T3
TE < TE máx
Par de apriete a través del eje TD=T2+T3
TD < TD máx

1) Eficiencia no considerada

2) Para ejes de transmisión libres de fuerza radial

3) El eje "U" solo está permitido como eje de accionamiento en la 2ª bomba de una bomba combinada del mismo tamaño.

4) Anotar el par de entrada máximo para el eje S!