Axial Piston Fixed Pump A17FO Series 10

1.Bent Axis Design;

2.Optimized for Mobile Drives;

3.Compact and Lightweight Construction;

4.Direct Power Take-Off Installation;

5.Excellent Suction Characteristics;

6.High Overall Efficiency

Detaillierte Beschreibung

This product adopts a reliable bent axis design with a rational structural layout, delivering stable and adaptive performance for diverse operating conditions. Optimized exclusively for mobile drive systems, it perfectly accommodates dynamic load changes and complex working scenarios of mobile machinery and vehicle-mounted equipment. Featuring a compact and lightweight construction, it eliminates redundant structural designs, effectively saving installation space and reducing overall equipment load while maintaining structural durability. It supports direct power take-off installation without complicated adapter parts, simplifying assembly procedures and cutting down installation time and costs. Equipped with excellent suction characteristics, the device ensures smooth and stable suction operation, effectively avoiding cavitation and flow interruption during operation to adapt to various medium transmission conditions. With optimized internal transmission and structural design, it achieves high overall efficiency, minimizing energy loss and delivering consistent, long-term operational stability for improved working performance and cost-effectiveness.

Auswahl und Preisanfrage

Diese Produktreihe sollte anhand des freigegebenen Hydraulikkreises ausgewählt werden. Bestätigen Sie vor der endgültigen Auswahl den erforderlichen Volumenstrom oder das Verdrängungsvolumen, den Dauer- und Spitzendruck, die Antriebsdrehzahl, die Steuerungsart, das Fluid und die Einbauschnittstelle.

Angaben für Ihre Angebotsanfrage

  • Erforderliches Verdrängungsvolumen oder Förderstrom bei Betriebsdrehzahl
  • Dauerdruck und Spitzendruck des Systems
  • Antriebsgeschwindigkeit, Steuerungsanforderung und Schaltungsart
  • Montageflansch, Welle, Anschlüsse, Fluid- und Filtrationsanforderung

Verwandte Ressourcen

Angebot anfordern · Download-Center · OEM / ODM

Technische Daten

Größe NG 23 32 45 63 80 107
Geometrisches Fördervolumen pro Umdrehung Vg cm3 22.9 32 45.6 63 80.4 106.7
Speed maximum1) nnom2) U/min 3050 2750 2650 2200 2150 2000
nMax3) U/min 4300 3900 3800 3200 3100 2800
Fluss at nnom qv l/min 70 88 121 139 173 213
Macht at nnom and Δp= 350 bar P kW 41 51 71 81 101 124
Drehmoment at Δp = 350 bar T Machs gut 127 178 254 351 448 594
Rotary stiffness C kNm/rad 2.56 3.12 4.18 6.25 8.73 11.2
Moment of inertia for rotary group JTW kgm2 0.0012 0.0012 0.003 0.0042 0.0072 0.0116
Maximale Winkelbeschleunigung α rad/s2 6500 6500 14600 7500 6000 4500
Fallzahl V l 0.25 0.29 0.4 0.5 0.6 0.75
Mass moment TG Machs gut 4.7 4.7 8.6 9.9 15.3 20
Mass (approx.) m kg 5.9 5.9 8.4 9.3 12.3 15.0

Maximum speed (limiting speed)

Bestimmung der Betriebskennlinien

Fluss qv=(Vg×n×ηv)/1000 [l/min]
Drehmoment T=(Vg×Δp)/(20×π×ηhm) [Nm]
Macht P=(2π×T×n)/60000=(qv×Δp)/(600×ηt) [kW]

Schlüssel

Vg=Displacement per revolution [cm3]

Δp=Differential pressure [bar]

n=Speed [rpm]

ηv=Volumetric efficiency

ηhm=Hydraulic-mechanical efficiency

ηt=Total efficiency ( ηtv × ηhm)

Note

▶Theoretical values, without efficiency and tolerances;values rounded.

▶Operation above the maximum values or below the minimum values may result in a loss of function,a reduced service life or in the destruction of the axial piston unit. Other permissible limit values, such as speed variation, reduced angular acceleration as a function of the frequency and the permissible angular acceleration at start (lower than the maximum angular acceleration) can be found in data sheet 90261.

1) The values are applicable:

- for the optimum viscosity range from νentscheiden = 36 bis 16 mm2/s

- for hydraulic fluids based on mineral oils.

2) The values apply at absolute pABS =1 bar at suction port S

3) Maximum speed (speed limit) with increased inlet pressure pABS at suction port S (see diagram).

Permissible axial forces of the drive shaft

Größe NG 23 32 45 63 80 107
Maximum axial force, at standstill or pressure-free operation +FAch, Max N 0 0 0 0 0 0
-FAch, Max N 24 33 43 53 60 71

Note

▶The values given are maximum values and do not apply

to continuous operation.

▶The permissible axial force in direction -FAxt  is to be avoided as the lifetime of the bearing is reduced.

▶Radial forces are not permissible.

A17FO