PVE Open Circuit Variable Piston Pump

The PVE open-circuit piston pump uses a variable swashplate arrangement. The existing table distinguishes PVE012, PVE19 and PVE21 and includes different pressure and input-speed ratings, so the selected model must remain attached to its own values.

  • Swashplate displacement adjustment
  • Existing table distinguishes PVE012, PVE19 and PVE21
  • Pump-specific case-fill instructions
  • Separate inlet, outlet and drain limits

PRANCE HYDRAULIC · PRODUCT SERIES

PVE Open Circuit Variable Piston Pump

Axial piston; swashplate variable displacement · Open circuit

The PVE open-circuit piston pump uses a variable swashplate arrangement. The existing table distinguishes PVE012, PVE19 and PVE21 and includes different pressure and input-speed ratings, so the selected model must remain attached to its own values.

Modèle

✓PVE original product photograph
JCEAxial piston; swashplate variable displacement
Demander un devisVoir les données techniques et la fiche technique

Confirm the complete model and approved specification with Prance Hydraulic. Product-series references alone do not establish interchangeability.

Étude de configuration · Documentation technique · Sélection de produits

Détails du produit

  • Swashplate displacement adjustment
  • Existing table distinguishes PVE012, PVE19 and PVE21
  • Pump-specific case-fill instructions
  • Separate inlet, outlet and drain limits

CATÉGORIES : Pompe à cylindrée variable, Pompe à piston

PVE Features & Application

Swashplate displacement adjustment

Specify the full MS order code, installation drawing and operating duty so the quotation can identify the proposed configuration.

Existing table distinguishes PVE012, PVE19 and PVE21

Specify the full MS order code, installation drawing and operating duty so the quotation can identify the proposed configuration.

Pump-specific case-fill instructions

Compare the required flow at the actual drive speed and pressure. Check the selected variant rather than combining maxima from different rows.

Separate inlet, outlet and drain limits

Keep continuous, intermittent and peak conditions separate. Use the row for the selected size and configuration.

PVE Specifications

Series / modelJCE
Product typePVE Open Circuit Variable Piston Pump
ConceptionAxial piston; swashplate variable displacement
Circuit / selectionCircuit ouvert
Published modelsPVE012, PVE19 and PVE21
Listed displacement25, 41 and 45 cm³/rev respectively
Published speed/pressure rows3000 rpm / 210 bar; 2400 rpm / 210 bar; 2400 rpm / 186 bar respectively; confirm applicable conditions

PVE Selection & Configuration

The PVE open-circuit piston pump uses a variable swashplate arrangement. The existing table distinguishes PVE012, PVE19 and PVE21 and includes different pressure and input-speed ratings, so the selected model must remain attached to its own values.

Review the drain route as part of the installation, not after the pump is selected. The existing startup instructions require case filling and a drain connection to the reservoir. Confirm the approved mounting position and steady case-pressure limit for the supplied unit.

cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits

Your Application.
The Right Configuration.

Hydraulic pumps · Hydraulic motors · Hydraulic valves

Send the MS nameplate, operating requirements and installation drawing for a configuration review before quoting.

  • Model review — send the full model code or an existing nameplate photograph.
  • Interface matching — confirm shaft, mounting flange, rotation and ports.
  • Operating conditions — provide flow, pressure, speed, fluid and duty cycle.
  • Documentation — request the relevant product data and drawings for your review.
Prance workshop with a row of production equipment

PVE Buying Guide

Use this sequence to prepare the PVE configuration for review and quotation.

  1. Define required flow at the actual drive speed and continuous pressure.
  2. Identify peak pressure, duration and the work cycle.
  3. Confirm the selected displacement control and any auxiliary-drive requirement.
  4. Match rotation viewed from the shaft end, shaft, flange and ports.
  5. Review inlet conditions, drain routing and the installation envelope.
  6. Confirm fluid, viscosity, temperature, filtration and seals.
  7. Approve the complete model, control, drawing, quantity and delivery terms.
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits

Selection, Documentation & Project Support

Prance technical team image from its company website

Selection Support

Learn more →

Share your hydraulic circuit, operating point and installation requirements for a configuration discussion.


Flow · Pressure · Speed · Interfaces
Prance quality standards image from its company website

Technical Resources

Learn more →

Review product documentation, model codes and technical data before finalizing the specification.


Datasheets · Model codes · Drawings
Prance sales team image from its company website

cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits

Learn more →

cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits.


cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits

Configuration, Quantity & Delivery

Confirm the complete MS code, approved drawing and operating limits. Availability, quantity, documentation and delivery date are confirmed in the quotation.

Discuss Your PVE Application

Send the full model code, operating duty, installation details and quantity.

Request a PVE Quotation

PVE Questions Before Ordering

What type of product is the PVE?

PVE Open Circuit Variable Piston Pump. Design: Axial piston; swashplate variable displacement. Open circuit. Confirm the complete order code for the offered version.

Can a similar pump replace the PVE?

cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits.

cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits

Define required flow at the actual drive speed and continuous pressure. Identify peak pressure, duration and the work cycle. Attach the nameplate, complete order code, installation drawing and required quantity.

PVE Technical Data & Documents

View PVE catalog data and operating conditions

cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits.

Données techniques

Préparation à la mise en service

Avant de démarrer une pompe PVE, remplir le carter avec du fluide hydraulique propre du système par l'orifice de vidange situé le plus haut. La conduite de vidange du carter doit être raccordée au réservoir en dessous du niveau d'huile. Pour les configurations comportant plusieurs pompes, y compris des sections qui ne sont pas de type PVE, les exigences des unités non-PVE doivent également être prises en compte.

Montage

Eaton Hydraulics recommande de monter horizontalement ces pompes à pistons de la série PVE.

CARACTÉRISTIQUES NOMINALES DE CYLINDRÉE, DE VITESSE ET DE PRESSION

Système de désignation des modèles Cylindrée cm3/tr (po3/tr) Vitesse d'entrée nominale Pression maximale bar (psi)
Pompe côté arbre Pompe côté couvercle (À une pression d’entrée de 0 psig) Extrémité arbre Extrémité couvercle
PVE012 25(1.54) - 3000 210(3000) -
PVE19 41 (2.50) - 2400 210(3000) -
PVE21 45 (2.75) - 2400 186(2700) -
*Le produit ombré peut ne pas être disponible

LIMITES DE PRESSION

Orifice Plage de pression
Entrée** De 0,2 bar à 2,0 bar (vide de 5 po Hg à 30 psi)
Sortie Voir les pressions maximales indiquées ci-dessus
Drain* 0,35 bar (5 psig) maximum
*Integral relief valve protects pump by limiting case pressure peaks to 0,7 bar (10 psi) above inlet pressure. Flow from valve returned directly to pump inlet. Case drain line required to limit steady-state case pressure. ** Speed details. For non-intergrated units only
Watch PVE Product Video
PVE product video

Request a PVE Quotation

Tell us your required configuration, quantity and application.

Démo du formulaire de contact
PVE original product photograph

Données techniques

Préparation à la mise en service

Avant de démarrer une pompe PVE, remplir le carter avec du fluide hydraulique propre du système par l'orifice de vidange situé le plus haut. La conduite de vidange du carter doit être raccordée au réservoir en dessous du niveau d'huile. Pour les configurations comportant plusieurs pompes, y compris des sections qui ne sont pas de type PVE, les exigences des unités non-PVE doivent également être prises en compte.

Montage

Eaton Hydraulics recommande de monter horizontalement ces pompes à pistons de la série PVE.

CARACTÉRISTIQUES NOMINALES DE CYLINDRÉE, DE VITESSE ET DE PRESSION

Système de désignation des modèles Cylindrée cm3/tr (po3/tr) Vitesse d'entrée nominale Pression maximale bar (psi)
Pompe côté arbre Pompe côté couvercle (À une pression d’entrée de 0 psig) Extrémité arbre Extrémité couvercle
PVE012 25(1.54) - 3000 210(3000) -
PVE19 41 (2.50) - 2400 210(3000) -
PVE21 45 (2.75) - 2400 186(2700) -

*Le produit ombré peut ne pas être disponible

LIMITES DE PRESSION

Orifice Plage de pression
Entrée** De 0,2 bar à 2,0 bar (vide de 5 po Hg à 30 psi)
Sortie Voir les pressions maximales indiquées ci-dessus
Drain* 0,35 bar (5 psig) maximum

*La soupape de décharge intégrée protège la pompe en limitant les pics de pression dans le carter à 0,7 bar

(10 psi) au-dessus de la pression d’entrée. Le débit provenant de la soupape est renvoyé directement vers l’entrée de la pompe.

Une conduite de drainage du carter est nécessaire pour limiter la pression du carter en régime permanent.

** Détails de vitesse.

Pour les unités non intégrées uniquement

JCE