Wenzhou Prance Hydraulic Equipment Co., Ltd
4WREE Proportional Valve with Position Feedback
The 4WREE proportional valve combines direction and flow control with electrical spool-position feedback. The existing data distinguishes 4WRE and 4WREE variants, so electronics, weight and connection details must be selected from the correct variant.
- Electrical spool-position feedback
- Spring-centered spool
- Subplate mounting
- Sizes 6 and 10 distinguished in the table
PRANCE HYDRAULIC · PRODUCT SERIES
Proportional directional spool valve with electrical position feedback · Subplate-mounted flow and direction control
The 4WREE proportional valve combines direction and flow control with electrical spool-position feedback. The existing data distinguishes 4WRE and 4WREE variants, so electronics, weight and connection details must be selected from the correct variant.
Model

Confirm the complete model and approved specification with Prance Hydraulic. Product-series references alone do not establish interchangeability.
Configuration review · Technical documentation · Product selection
Detalhes do Produto
- Electrical spool-position feedback
- Spring-centered spool
- Subplate mounting
- Sizes 6 and 10 distinguished in the table
CATEGORIES: Válvula hidráulica, Válvula Proporcional
4WREE Features & Application
Electrical spool-position feedback
Spool feedback concerns the valve position. Confirm whether the machine also requires separate actuator position or pressure feedback.
Spring-centered spool
Specify the full MS order code, installation drawing and operating duty so the quotation can identify the proposed configuration.
Subplate mounting
Check pilot diameter, bolt pattern, shaft engagement or port pattern against the approved installation drawing.
Sizes 6 and 10 distinguished in the table
Include the series and all order-code suffixes in the enquiry. A common nominal size does not establish compatibility.
4WREE Specifications
| Series / model | 4WREE |
|---|---|
| Product type | 4WREE Proportional Valve with Position Feedback |
| Design | Proportional directional spool valve with electrical position feedback |
| Circuit / selection | Subplate-mounted flow and direction control |
| Published nominal sizes | 6 and 10 |
| Feedback | Electrical spool position |
| Mounting pattern | DIN 24340 form A / ISO 4401 / CETOP reference in the existing description |
4WREE Selection & Configuration
The 4WREE proportional valve combines direction and flow control with electrical spool-position feedback. The existing data distinguishes 4WRE and 4WREE variants, so electronics, weight and connection details must be selected from the correct variant.
Confirm the command interface and connector pin assignment before replacing a valve. Spool-position feedback describes the valve control loop; it does not measure actuator position or eliminate the need to review the external machine controller.

cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits.
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits.
Hydraulic pumps · Hydraulic motors · Hydraulic valves
Send the MS nameplate, operating requirements and installation drawing for a configuration review before quoting.
- Model review — send the full model code or an existing nameplate photograph.
- Interface matching — confirm shaft, mounting flange, rotation and ports.
- Operating conditions — provide flow, pressure, speed, fluid and duty cycle.
- Documentation — request the relevant product data and drawings for your review.

4WREE Buying Guide
Use this sequence to prepare the 4WREE configuration for review and quotation.
- Select the circuit symbol and required de-energized spool position.
- State working flow, pressure and the pressure-drop condition for rated flow.
- Review spool overlap and command behavior during startup and switch-off.
- Confirm nominal size, subplate pattern, port and seal requirements.
- Match supply voltage, command input, connector and pin assignment.
- Review pilot supply, drain and feedback where the selected valve uses them.
- Approve the exact valve code, circuit drawing, quantity and documentation.

Selection, Documentation & Project Support

Selection Support
Learn more →Share your hydraulic circuit, operating point and installation requirements for a configuration discussion.
Flow · Pressure · Speed · Interfaces

Technical Resources
Learn more →Review product documentation, model codes and technical data before finalizing the specification.
Datasheets · Model codes · Drawings

Project Inquiries
Learn more →Send your required model, quantity, application and project requirements to discuss your inquiry.
Product inquiries · Configuration review
Configuration, Quantity & Delivery
Confirm the complete MS code, approved drawing and operating limits. Availability, quantity, documentation and delivery date are confirmed in the quotation.
Discuss Your 4WREE Application
Send the full model code, operating duty, installation details and quantity.
Request a 4WREE Quotation4WREE Questions Before Ordering
What type of product is the 4WREE?
4WREE Proportional Valve with Position Feedback. Design: Proportional directional spool valve with electrical position feedback. Subplate-mounted flow and direction control. Confirm the complete order code for the offered version.
Can a similar valve replace the 4WREE?
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits.
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits
Select the circuit symbol and required de-energized spool position. State working flow, pressure and the pressure-drop condition for rated flow. Attach the nameplate, complete order code, installation drawing and required quantity.
4WREE Technical Data & Documents
View 4WREE catalog data and operating conditions
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits.
Dados técnicos (Para aplicações fora destes parâmetros, consulte-nos!)
Geral
| Tamanhos | Tamanho | 6 | 10 | |
| Peso | – Type 4WRE | kg | 2.2 | 6.3 |
| – Type 4WREE | kg | 2.4 | 6.5 | |
| Posição de instalação | Qualquer, preferencialmente horizontal | |||
| Gama de temperaturas ambiente | – Type 4WRE | ℃ | -20 a +70 | |
| – Type 4WREE | ℃ | -20 a +50 | ||
| Gama de temperaturas de armazenamento | ℃ | -20 a +80 | ||
| MTTFd valores de acordo com a EN ISO 13849 | Anos | 150 1) (para mais informações consulte a folha de dados 08012) | ||
hidráulico (medido com HLP46, θpetróleo= 40 °C + 5 °C e p = 100 bar)
| Maximum operating pressure | – Port A,B,P | bar | 315 | |
| – Port T | bar | 210 | ||
| Caudal nominal qPara maiores de 18 anos com Δp = 10 bar | l/min | 4,8,16,32 | 25,50,75 | |
| Caudal máximo recomendado | l/min | 80 | 180 | |
| Fluido hidráulico | Ver tabela abaixo | |||
| Gama de temperaturas do fluido hidráulico | ℃ | -20 a +80 (preferencialmente +40 a +50) | ||
| Gama de viscosidade | mm2/s | 20 a 380 (de preferência 30 a 46) | ||
| Grau máximo admissível de contaminação do fluido hidráulico, classe de limpeza de acordo com a norma ISO 4406 (c) | Classe 20/18/15 2) | |||
| Histerese | % | ≤ 1 | ||
| Amplitude de inversão | % | ≤ 0,05 | ||
| Sensibilidade de resposta | % | ≤ 0,05 | ||
| Desvio zero após mudança de hidráulico | %/10K | ≤ 0,15 | ||
| temperatura do fluido e pressão de serviço | %/100 bar | ≤ 0,1 | ||
| Fluido hidráulico | Classificação | Suitable sealing materials | Normas | |
| Óleos minerais e hidrocarbonetos conexos | HL, HLP | NBR, FKM | DIN 51524 | |
| Resistente ao fogo | contendo água | HFC (Fuchs HYDROTHERM 46M, Petrofer Ultra Safe 620) | NBR | ISO 12922 |
| Important information on hydraulic fluids! -For more information and data on the use of other hydraulic fluids refer to data sheet 90220 or contact us! -There may be limitations regarding the technical valve data (temperature, pressure range, life cycle, maintenance intervals, etc.)! -The flash point of the process and operating medium used must be 40 K greater than the maximum solenoid surface temperature. – Flame-resistant- containing water:The maximum pressure differential per control edge 175 bar. Pressure preloading at the tank port > 20% of the pressure differential; otherwise, increased cavitation. – Life cycle as compared to operation with mineral oil HL,HLP 50% to 100% | ||||
Elétrico
| Tamanho | Tamanho | 6 | 6 | |
| Tipo de tensão | Tensão contínua | |||
| Bobina do solenoide | – Cold value at 20 ℃ | Ω | 2.65 | 4.55 |
| resistência | Valor máximo de aquecimento | Ω | 4.05 | 6.82 |
| Ciclo de trabalho | % | 100 | ||
| Temperatura máxima da bobina 1) | ℃ | até 150 | ||
| Electrical connection see page 8 and 9 | – Type 4WRE | Com ficha de acordo com a norma DIN EN 175301-803 e ISO 4400 | ||
| Conetor fêmea de acordo com a norma DIN EN 175301-803 e ISO 4400 2) | ||||
| – Type 4WREE | Com conector DIN EN 175201-804 | |||
| Conetor fêmea DIN EN 175201-804 2) IP65 com conector acoplado montado e bloqueado | ||||
| Classe de proteção da válvula de acordo com a norma EN 60529 | IP65 com conector acoplado montado e bloqueado | |||
Eletrónica de controlo
| Tipo 4WRE | versão 4/3 | Digital | VT-VRPD-2-2X/V0/0 de acordo com a RE 30126 | |
| Entrada do amplificador | ||||
| formato de cartão europeu 2) | Analógico | VT-VRPA2-1-1X/V0 according to data sheet 30119 | VT-VRPA2-2-1X/VO de acordo com a folha de dados 30119 | |
| Módulo amplificador 2) | Analógico | VT-MRPA2-1 according to data sheet 30219 | VT-MRPA2-2 de acordo com a folha de dados 30219 | |
| Type 4WRE…A… | versão 4/2 | Analógico | VT-MRPA1-1 according to data sheet 30219 | VT-MRPA1-2 de acordo com a ficha técnica 30219 |
| Módulo amplificador 2) | ||||
| Tipo 4WREE | módulo de valor de comando analógico | Integrado na válvula, ver página 9 | ||
| VT- SWMA-1-1X/… according to data sheet 29902 | ||||
| módulo de valor de comando analógico | VT-SWMAK-1-1X/… according to data sheet 29903 | |||
| placa de valor de comando analógico | cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits | |||
| placa de valor de comando digital | VT-HACD-1-1X/… according to data sheet 30143 | |||
| Tensão de alimentação | Tensão nominal | VDC | 24 | |
| valor limite inferior | V | 19.4 | ||
| valor limite superior | V | 35 | ||
| Consumo atual | Imáx | A | <2 | |
| do amplificador | Corrente de impulsos | A | 3 | |
Aviso:
Para obter informações sobre os testes de simulação ambiental para as áreas de EMC (compatibilidade eletromagnética), clima e carga mecânica, consulte a folha de dados 29061-U (declaração de compatibilidade ambiental).Watch 4WREE Product Video
Related Selection Resources
Request a 4WREE Quotation
Tell us your required configuration, quantity and application.
Dados técnicos (Para aplicações fora destes parâmetros, consulte-nos!)
Geral
| Tamanhos | Tamanho | 6 | 10 | |
| Peso | - Tipo 4WRE | kg | 2.2 | 6.3 |
| - Tipo 4WREE | kg | 2.4 | 6.5 | |
| Posição de instalação | Qualquer, preferencialmente horizontal | |||
| Gama de temperaturas ambiente | - Tipo 4WRE | ℃ | -20 a +70 | |
| - Tipo 4WREE | ℃ | -20 a +50 | ||
| Gama de temperaturas de armazenamento | ℃ | -20 a +80 | ||
| MTTFd valores de acordo com a EN ISO 13849 | Anos | 150 1) (para mais informações consulte a folha de dados 08012) | ||
hidráulico (medido com HLP46, θpetróleo= 40 °C + 5 °C e p = 100 bar)
| Funcionamento máximo pressão |
- Porta A,B,P | bar | 315 | |
| - Porto T | bar | 210 | ||
| Caudal nominal qPara maiores de 18 anos com Δp = 10 bar | l/min | 4,8,16,32 | 25,50,75 | |
| Caudal máximo recomendado | l/min | 80 | 180 | |
| Fluido hidráulico | Ver tabela abaixo | |||
| Gama de temperaturas do fluido hidráulico | ℃ | -20 a +80 (preferencialmente +40 a +50) | ||
| Gama de viscosidade | mm2/s | 20 a 380 (de preferência 30 a 46) | ||
| Grau máximo admissível de contaminação do fluido hidráulico, classe de limpeza de acordo com a norma ISO 4406 (c) | Classe 20/18/15 2) | |||
| Histerese | % | ≤ 1 | ||
| Amplitude de inversão | % | ≤ 0,05 | ||
| Sensibilidade de resposta | % | ≤ 0,05 | ||
| Desvio zero após mudança de hidráulico | %/10K | ≤ 0,15 | ||
| temperatura do fluido e pressão de serviço | %/100 bar | ≤ 0,1 | ||
1)Com os tipos de cursor de comando E, E1, EA, W, W1, WA; na direção longitudinal do cursor de comando, existe uma sobreposição positiva suficiente sem carga de choque/vibração; observar a posição de montagem em relação à direção principal de aceleração.
2) As classes de limpeza especificadas para os componentes devem ser respeitadas nos sistemas hidráulicos. A filtragem eficaz evita avarias e, simultaneamente, aumenta a vida útil dos componentes.
| Fluido hidráulico | Classificação | Adequado materiais de vedação |
Normas | |
| Óleos minerais e hidrocarbonetos conexos | HL, HLP | NBR, FKM | DIN 51524 | |
| Resistente ao fogo | contendo água | HFC (Fuchs HYDROTHERM 46M, Petrofer Ultra Safe 620 |
NBR | ISO 12922 |
| Informação importante sobre fluidos hidráulicos! -Para mais informações e dados sobre a utilização de outros fluidos hidráulicos, consulte a ficha técnica 90220 ou contacte-nos! -Podem existir limitações relativamente aos dados técnicos da válvula (temperatura, gama de pressões, vida útil, intervalos de manutenção, etc.)! O ponto de inflamação do processo e do fluido operacional utilizados deve ser 40 K superior à temperatura máxima da superfície do solenóide. - Resistente ao fogo - contém água: Diferencial de pressão máximo por borda de controlo: 175 bar. Pré-carga de pressão na porta do depósito > 20% do diferencial de pressão; caso contrário, aumenta a cavitação. Ciclo de vida em comparação com o funcionamento com óleo mineral HL, HLP 50% a 100% |
||||
Elétrico
| Tamanho | Tamanho | 6 | 6 | |
| Tipo de tensão | Tensão contínua | |||
| Bobina do solenoide | - Valor a frio a 20 ℃ | Ω | 2.65 | 4.55 |
| resistência | Valor máximo de aquecimento | Ω | 4.05 | 6.82 |
| Ciclo de trabalho | % | 100 | ||
| Temperatura máxima da bobina 1) | ℃ | até 150 | ||
| Ligação elétrica ver página 8 e 9 |
- Tipo 4WRE | Com ficha de acordo com a norma DIN EN 175301-803 e ISO 4400 | ||
| Conetor fêmea de acordo com a norma DIN EN 175301-803 e ISO 4400 2) | ||||
| - Tipo 4WREE | Com conector DIN EN 175201-804 | |||
| Conetor fêmea DIN EN 175201-804 2) IP65 com conector acoplado montado e bloqueado |
||||
| Classe de proteção da válvula de acordo com a norma EN 60529 | IP65 com conector acoplado montado e bloqueado | |||
Eletrónica de controlo
| Tipo 4WRE | versão 4/3 | Digital | VT-VRPD-2-2X/V0/0 de acordo com a RE 30126 | |
| Entrada do amplificador | ||||
| formato de cartão europeu 2) | Analógico | VT-VRPA2-1-1X/V0 de acordo com a ficha técnica 30119 |
VT-VRPA2-2-1X/VO de acordo com a folha de dados 30119 | |
| Módulo amplificador 2) | Analógico | VT-MRPA2-1 de acordo com a ficha técnica 30219 |
VT-MRPA2-2 de acordo com a folha de dados 30219 | |
| Tipo 4WRE...A... | versão 4/2 | Analógico | VT-MRPA1-1 de acordo com a ficha técnica 30219 |
VT-MRPA1-2 de acordo com a ficha técnica 30219 |
| Módulo amplificador 2) | ||||
| Tipo 4WREE | módulo de valor de comando analógico | Integrado na válvula, ver página 9 | ||
| VT- SWMA-1-1X/...de acordo com a folha de dados 29902 | ||||
| módulo de valor de comando analógico | VT-SWMAK-1-1X/... de acordo com a folha de dados 29903 | |||
| placa de valor de comando analógico | VT-SWKA-1-1X/... de acordo com a folha de dados 30255 | |||
| placa de valor de comando digital | VT-HACD -1-1X/... de acordo com a folha de dados 30143 | |||
| Tensão de alimentação | Tensão nominal | VDC | 24 | |
| valor limite inferior | V | 19.4 | ||
| valor limite superior | V | 35 | ||
| Consumo atual | Imáx | A | <2 | |
| do amplificador | Corrente de impulsos | A | 3 | |
1)Devido às temperaturas que se verificam nas superfícies das bobinas do solenóide, é necessário cumprir as normas europeias ISO 13732-1 e EN ISO 4413!
2) Separar encomenda
Aviso:
Para obter informações sobre os testes de simulação ambiental para as áreas de EMC (compatibilidade eletromagnética), clima e carga mecânica, consulte a folha de dados 29061-U (declaração de compatibilidade ambiental).