Wenzhou Prance Hydraulic Equipment Co., Ltd.
4WREE Proportional Valve with Position Feedback
The 4WREE proportional valve combines direction and flow control with electrical spool-position feedback. The existing data distinguishes 4WRE and 4WREE variants, so electronics, weight and connection details must be selected from the correct variant.
- Electrical spool-position feedback
- Spring-centered spool
- Subplate mounting
- Sizes 6 and 10 distinguished in the table
PRANCE HYDRAULIC · PRODUCT SERIES
Proportional directional spool valve with electrical position feedback · Subplate-mounted flow and direction control
The 4WREE proportional valve combines direction and flow control with electrical spool-position feedback. The existing data distinguishes 4WRE and 4WREE variants, so electronics, weight and connection details must be selected from the correct variant.
Model

Confirm the complete model and approved specification with Prance Hydraulic. Product-series references alone do not establish interchangeability.
Configuration review · Technical documentation · Product selection
Produktdetails
- Electrical spool-position feedback
- Spring-centered spool
- Subplate mounting
- Sizes 6 and 10 distinguished in the table
CATEGORIES: Hydraulikventil, Proportionalventil
4WREE Features & Application
Electrical spool-position feedback
Spool feedback concerns the valve position. Confirm whether the machine also requires separate actuator position or pressure feedback.
Spring-centered spool
Specify the full MS order code, installation drawing and operating duty so the quotation can identify the proposed configuration.
Subplate mounting
Check pilot diameter, bolt pattern, shaft engagement or port pattern against the approved installation drawing.
Sizes 6 and 10 distinguished in the table
Include the series and all order-code suffixes in the enquiry. A common nominal size does not establish compatibility.
4WREE Specifications
| Series / model | 4WREE |
|---|---|
| Product type | 4WREE Proportional Valve with Position Feedback |
| Design | Proportional directional spool valve with electrical position feedback |
| Circuit / selection | Subplate-mounted flow and direction control |
| Published nominal sizes | 6 and 10 |
| Feedback | Electrical spool position |
| Mounting pattern | DIN 24340 form A / ISO 4401 / CETOP reference in the existing description |
4WREE Selection & Configuration
The 4WREE proportional valve combines direction and flow control with electrical spool-position feedback. The existing data distinguishes 4WRE and 4WREE variants, so electronics, weight and connection details must be selected from the correct variant.
Confirm the command interface and connector pin assignment before replacing a valve. Spool-position feedback describes the valve control loop; it does not measure actuator position or eliminate the need to review the external machine controller.

cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits.
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits.
Hydraulic pumps · Hydraulic motors · Hydraulic valves
Send the MS nameplate, operating requirements and installation drawing for a configuration review before quoting.
- Model review — send the full model code or an existing nameplate photograph.
- Interface matching — confirm shaft, mounting flange, rotation and ports.
- Operating conditions — provide flow, pressure, speed, fluid and duty cycle.
- Documentation — request the relevant product data and drawings for your review.

4WREE Buying Guide
Use this sequence to prepare the 4WREE configuration for review and quotation.
- Select the circuit symbol and required de-energized spool position.
- State working flow, pressure and the pressure-drop condition for rated flow.
- Review spool overlap and command behavior during startup and switch-off.
- Confirm nominal size, subplate pattern, port and seal requirements.
- Match supply voltage, command input, connector and pin assignment.
- Review pilot supply, drain and feedback where the selected valve uses them.
- Approve the exact valve code, circuit drawing, quantity and documentation.

Selection, Documentation & Project Support

Selection Support
Learn more →Share your hydraulic circuit, operating point and installation requirements for a configuration discussion.
Flow · Pressure · Speed · Interfaces

Technical Resources
Learn more →Review product documentation, model codes and technical data before finalizing the specification.
Datasheets · Model codes · Drawings

Project Inquiries
Learn more →Send your required model, quantity, application and project requirements to discuss your inquiry.
Product inquiries · Configuration review
Configuration, Quantity & Delivery
Confirm the complete MS code, approved drawing and operating limits. Availability, quantity, documentation and delivery date are confirmed in the quotation.
Discuss Your 4WREE Application
Send the full model code, operating duty, installation details and quantity.
Request a 4WREE Quotation4WREE Questions Before Ordering
What type of product is the 4WREE?
4WREE Proportional Valve with Position Feedback. Design: Proportional directional spool valve with electrical position feedback. Subplate-mounted flow and direction control. Confirm the complete order code for the offered version.
Can a similar valve replace the 4WREE?
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits.
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits
Select the circuit symbol and required de-energized spool position. State working flow, pressure and the pressure-drop condition for rated flow. Attach the nameplate, complete order code, installation drawing and required quantity.
4WREE Technical Data & Documents
View 4WREE catalog data and operating conditions
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits.
Technische Daten (Für Anwendungen außerhalb dieser Parameter sprechen Sie uns bitte an!)
Allgemein
| Größen | Größe | 6 | 10 | |
| Gewicht | – Type 4WRE | kg | 2.2 | 6.3 |
| – Type 4WREE | kg | 2.4 | 6.5 | |
| Einbaulage | Beliebig, vorzugsweise horizontal | |||
| Umgebungstemperaturbereich | – Type 4WRE | ℃ | -20 bis +70 | |
| – Type 4WREE | ℃ | -20 bis +50 | ||
| Lagertemperaturbereich | ℃ | -20 bis +80 | ||
| MTTFd Werte nach EN ISO 13849 | Jahre | 150 1) (für weitere Informationen siehe Datenblatt 08012) | ||
hydraulisch (gemessen mit HLP46, θÖl= 40 °C + 5 °C und p = 100 bar)
| Maximum operating pressure | – Port A,B,P | Bar | 315 | |
| – Port T | Bar | 210 | ||
| NennvolumenstromV-limitiert mit Δp = 10 bar | l/min | 4,8,16,32 | 25,50,75 | |
| Empfohlener maximaler Durchfluss | l/min | 80 | 180 | |
| Hydraulikflüssigkeit | Siehe Tabelle unten | |||
| Temperaturbereich der Hydraulikflüssigkeit | ℃ | -20 bis +80 (vorzugsweise +40 bis +50) | ||
| Viskositätsbereich | mm2/s | 20 bis 380 (vorzugsweise 30 bis 46) | ||
| Maximal zulässiger Verschmutzungsgrad der Hydraulikflüssigkeit, Reinheitsklasse nach ISO 4406 (c) | Klasse 20/18/15 2) | |||
| Hysterese | % | ≤ 1 | ||
| Inversionsbereich | % | ≤ 0,05 | ||
| Antwortsensitivität | % | ≤ 0,05 | ||
| Nullpunktverschiebung bei Hydraulikwechsel | %/10K | ≤ 0,15 | ||
| Medientemperatur und Betriebsdruck | %/100 bar | ≤ 0,1 | ||
| Hydraulikflüssigkeit | Klassifikation | Suitable sealing materials | Standards | |
| Mineralöle und verwandte Kohlenwasserstoffe | HL, HLP | NBR, FKM | DIN 51524 | |
| flammhemmend | wasserhaltig | HFC (Fuchs HYDROTHERM 46M, Petrofer Ultra Safe 620) | NBR | ISO 12922 |
| Important information on hydraulic fluids! -For more information and data on the use of other hydraulic fluids refer to data sheet 90220 or contact us! -There may be limitations regarding the technical valve data (temperature, pressure range, service life , maintenance intervals, etc.)! -The flash point of the process and operating medium used must be 40 K higher than the maximum solenoid surface temperature. – Flame-resistant- wate-containingr: Maximum pressure differential per control edge 175 bar. Pressure pre-loading at the tank port > 20% of the pressure differential; otherwise, increased cavitation. Life cycle as compared to operation with mineral oil HL,HLP 50% to 100% | ||||
Elektrisch
| Größe | Größe | 6 | 6 | |
| Spannungsart | Gleichspannung | |||
| Magnetspule | – Cold value at 20 ℃ | Ω | 2.65 | 4.55 |
| Widerstand | Maximaler Heißwert | Ω | 4.05 | 6.82 |
| Einschaltdauer | % | 100 | ||
| Maximale Spulentemperatur 1) | ℃ | bis zu 150 | ||
| Electrical connection see page 8 and 9 | – Type 4WRE | Mit Steckverbindung nach DIN EN 175301-803 und ISO 4400 | ||
| Gegenstecker nach DIN EN 175301-803 und ISO 4400 2) | ||||
| – Type 4WREE | Mit Steckverbinder DIN EN 175201-804 | |||
| Gegenstecker DIN EN 175201-804 2) IP65 mit montiertem und verriegeltem Gegenstecker | ||||
| Schutzart des Ventils nach EN 60529 | IP65 mit montiertem und verriegeltem Gegenstecker | |||
Steuerelektronik
| Typ 4WRE | 4/3-Version | Digital | VT-VRPD-2-2X/V0/0 nach RE 30126 | |
| Verstärker ein | ||||
| Eurocard-Format 2) | Analog | VT-VRPA2-1-1X/V0 according to data sheet 30119 | VT-VRPA2-2-1X/VO gemäß Datenblatt 30119 | |
| Verstärkermodul 2) | Analog | VT-MRPA2-1 according to data sheet 30219 | VT-MRPA2-2 gemäß Datenblatt 30219 | |
| Type 4WRE…A… | 4/2-Version | Analog | cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits | VT-MRPA1-2 gemäß Datenblatt 30219 |
| Verstärkermodul 2) | ||||
| Typ 4WREE | Analogwert-Befehlsmodul | Im Ventil integriert, siehe Seite 9 | ||
| cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits | ||||
| Analogwert-Befehlsmodul | cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits | |||
| analoge Sollwertkarte | cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits | |||
| digitale Sollwertkarte | cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits | |||
| Versorgungsspannung | Nennspannung | VDC | 24 | |
| unterer Grenzwert | V | 19.4 | ||
| Obergrenzwert | V | 35 | ||
| Stromverbrauch | IMax | A | <2 | |
| des Verstärkers | Pulsstrom | A | 3 | |
Hinweis:
Informationen zur Umweltsimulationsprüfung für die Bereiche EMV (elektromagnetische Verträglichkeit), Klima und mechanische Belastung finden Sie im Datenblatt 29061-U (Erklärung zur Umweltverträglichkeit).cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits
Related Selection Resources
Request a 4WREE Quotation
Tell us your required configuration, quantity and application.
Technische Daten (Für Anwendungen außerhalb dieser Parameter sprechen Sie uns bitte an!)
Allgemein
| Größen | Größe | 6 | 10 | |
| Gewicht | - Typ 4WRE | kg | 2.2 | 6.3 |
| - Typ 4WREE | kg | 2.4 | 6.5 | |
| Einbaulage | Beliebig, vorzugsweise horizontal | |||
| Umgebungstemperaturbereich | - Typ 4WRE | ℃ | -20 bis +70 | |
| - Typ 4WREE | ℃ | -20 bis +50 | ||
| Lagertemperaturbereich | ℃ | -20 bis +80 | ||
| MTTFd Werte nach EN ISO 13849 | Jahre | 150 1) (für weitere Informationen siehe Datenblatt 08012) | ||
hydraulisch (gemessen mit HLP46, θÖl= 40 °C + 5 °C und p = 100 bar)
| Maximaler Betrieb Druck |
- Port A, B, P | Bar | 315 | |
| - Port T | Bar | 210 | ||
| NennvolumenstromV-limitiert mit Δp = 10 bar | l/min | 4,8,16,32 | 25,50,75 | |
| Empfohlener maximaler Durchfluss | l/min | 80 | 180 | |
| Hydraulikflüssigkeit | Siehe Tabelle unten | |||
| Temperaturbereich der Hydraulikflüssigkeit | ℃ | -20 bis +80 (vorzugsweise +40 bis +50) | ||
| Viskositätsbereich | mm2/s | 20 bis 380 (vorzugsweise 30 bis 46) | ||
| Maximal zulässiger Verschmutzungsgrad der Hydraulikflüssigkeit, Reinheitsklasse nach ISO 4406 (c) | Klasse 20/18/15 2) | |||
| Hysterese | % | ≤ 1 | ||
| Inversionsbereich | % | ≤ 0,05 | ||
| Antwortsensitivität | % | ≤ 0,05 | ||
| Nullpunktverschiebung bei Hydraulikwechsel | %/10K | ≤ 0,15 | ||
| Medientemperatur und Betriebsdruck | %/100 bar | ≤ 0,1 | ||
1)Bei den Steuerschieberarten E, E1, EA, W, W1, WA ist in Richtung der Schieberlängsachse eine ausreichende positive Überdeckung ohne Stoß-/Vibrationsbelastung vorhanden; die Einbaulage im Hinblick auf die Hauptbeschleunigungsrichtung ist zu beachten.
2) Bei Hydrauliksystemen müssen die für die Komponenten vorgeschriebenen Sauberkeitsklassen eingehalten werden. Eine effektive Filtration verhindert Störungen und erhöht gleichzeitig die Lebensdauer der Komponenten.
| Hydraulikflüssigkeit | Klassifikation | Geeignet Dichtungsmaterialien |
Standards | |
| Mineralöle und verwandte Kohlenwasserstoffe | HL, HLP | NBR, FKM | DIN 51524 | |
| flammhemmend | wasserhaltig | HFC (Fuchs HYDROTHERM 46M), Petrofer Ultra Safe 620 |
NBR | ISO 12922 |
| Wichtige Informationen zu Hydraulikflüssigkeiten! -Für weitere Informationen und Daten zur Verwendung anderer Hydraulikflüssigkeiten siehe Datenblatt 90220 oder kontaktieren Sie uns! -Es kann Einschränkungen hinsichtlich der technischen Ventil날daten (Temperatur, Druckbereich, Lebensdauer, Wartungsintervalle usw.) geben! Der Flammpunkt des verwendeten Prozess- und Betriebsmediums muss 40 K höher sein als die maximale Magnetoberflächentemperatur. - Flammhemmend – wasserhaltig: Maximaler Differenzdruck pro Steuerkante 175 bar. Druckvorbelastung am Tankanschluss > 20% des Differenzdrucks; andernfalls erhöhte Kavitation. Lebensdauer im Vergleich zum Betrieb mit Mineralöl HL, HLP 50% bis 100% |
||||
Elektrisch
| Größe | Größe | 6 | 6 | |
| Spannungsart | Gleichspannung | |||
| Magnetspule | - Kaltwert bei 20 ℃ | Ω | 2.65 | 4.55 |
| Widerstand | Maximaler Heißwert | Ω | 4.05 | 6.82 |
| Einschaltdauer | % | 100 | ||
| Maximale Spulentemperatur 1) | ℃ | bis zu 150 | ||
| Elektrischer Anschluss siehe Seite 8 und 9 |
- Typ 4WRE | Mit Steckverbindung nach DIN EN 175301-803 und ISO 4400 | ||
| Gegenstecker nach DIN EN 175301-803 und ISO 4400 2) | ||||
| - Typ 4WREE | Mit Steckverbinder DIN EN 175201-804 | |||
| Gegenstecker DIN EN 175201-804 2) IP65 mit montiertem und verriegeltem Gegenstecker |
||||
| Schutzart des Ventils nach EN 60529 | IP65 mit montiertem und verriegeltem Gegenstecker | |||
Steuerelektronik
| Typ 4WRE | 4/3-Version | Digital | VT-VRPD-2-2X/V0/0 nach RE 30126 | |
| Verstärker ein | ||||
| Eurocard-Format 2) | Analog | VT-VRPA2-1-1X/V0 laut Datenblatt 30119 |
VT-VRPA2-2-1X/VO gemäß Datenblatt 30119 | |
| Verstärkermodul 2) | Analog | VT-MRPA2-1 laut Datenblatt 30219 |
VT-MRPA2-2 gemäß Datenblatt 30219 | |
| Typ 4WRE...A... | 4/2-Version | Analog | VT-MRPA1-1 laut Datenblatt 30219 |
VT-MRPA1-2 gemäß Datenblatt 30219 |
| Verstärkermodul 2) | ||||
| Typ 4WREE | Analogwert-Befehlsmodul | Im Ventil integriert, siehe Seite 9 | ||
| VT-SWMA-1-1X/...gemäß Datenblatt 29902 | ||||
| Analogwert-Befehlsmodul | VT-SWMAK-1-1X/... gemäß Datenblatt 29903 | |||
| analoge Sollwertkarte | VT-SWKA-1-1X/... gemäß Datenblatt 30255 | |||
| digitale Sollwertkarte | VT-HACD -1-1X/... gemäß Datenblatt 30143 | |||
| Versorgungsspannung | Nennspannung | VDC | 24 | |
| unterer Grenzwert | V | 19.4 | ||
| Obergrenzwert | V | 35 | ||
| Stromverbrauch | IMax | A | <2 | |
| des Verstärkers | Pulsstrom | A | 3 | |
1)Aufgrund der an den Oberflächen der Magnetspulen auftretenden Temperaturen müssen die europäischen Normen ISO 13732-1 und EN ISO 4413 eingehalten werden!
2) Separate order -> Getrennte Bestellung
Hinweis:
Informationen zur Umweltsimulationsprüfung für die Bereiche EMV (elektromagnetische Verträglichkeit), Klima und mechanische Belastung finden Sie im Datenblatt 29061-U (Erklärung zur Umweltverträglichkeit).