Wenzhou Prance Hydraulic Equipment Co., Ltd
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits
The 4WRAE proportional valve controls hydraulic direction and flow by direct actuation. The series table includes both WRA and WRAE versions; the WRAE integrated-electronics data must be used when matching the controller and connector.
- Direct actuation
- Spring-centered control spool
- Integrated electronics for WRAE variant
- Subplate mounting
PRANCE HYDRAULIC · PRODUCT SERIES
Direct-operated proportional directional valve · Subplate-mounted direction and flow control
The 4WRAE proportional valve controls hydraulic direction and flow by direct actuation. The series table includes both WRA and WRAE versions; the WRAE integrated-electronics data must be used when matching the controller and connector.
Model

Confirm the complete model and approved specification with Prance Hydraulic. Product-series references alone do not establish interchangeability.
Configuration review · Technical documentation · Product selection
Detalhes do Produto
- Direct actuation
- Spring-centered control spool
- Integrated electronics for WRAE variant
- Subplate mounting
CATEGORIES: Válvula hidráulica, Válvula Proporcional
4WRAE Features & Application
Direct actuation
Specify the full MS order code, installation drawing and operating duty so the quotation can identify the proposed configuration.
Spring-centered control spool
Match the complete control option and its command requirements to the existing controller. Similar housings can use different control arrangements.
Integrated electronics for WRAE variant
Match the complete control option and its command requirements to the existing controller. Similar housings can use different control arrangements.
Subplate mounting
Check pilot diameter, bolt pattern, shaft engagement or port pattern against the approved installation drawing.
4WRAE Specifications
| Series / model | 4WRAE |
|---|---|
| Product type | cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits |
| Design | Direct-operated proportional directional valve |
| Circuit / selection | Subplate-mounted direction and flow control |
| Published nominal sizes | 6 and 10 |
| Listed WRAE command variants | A1: ±10 V; F1: 4–20 mA |
| Rated-flow test condition | Δp = 10 bar in the existing technical table |
4WRAE Selection & Configuration
The 4WRAE proportional valve controls hydraulic direction and flow by direct actuation. The series table includes both WRA and WRAE versions; the WRAE integrated-electronics data must be used when matching the controller and connector.
Confirm nominal size, spool characteristic and command input before choosing a rated flow. Rated flow is given at a specified pressure drop and is different from maximum permissible flow. Keep the WRA and WRAE electrical data separate during comparison.

cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits.
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits.
Hydraulic pumps · Hydraulic motors · Hydraulic valves
Send the MS nameplate, operating requirements and installation drawing for a configuration review before quoting.
- Model review — send the full model code or an existing nameplate photograph.
- Interface matching — confirm shaft, mounting flange, rotation and ports.
- Operating conditions — provide flow, pressure, speed, fluid and duty cycle.
- Documentation — request the relevant product data and drawings for your review.

4WRAE Buying Guide
Use this sequence to prepare the 4WRAE configuration for review and quotation.
- Select the circuit symbol and required de-energized spool position.
- State working flow, pressure and the pressure-drop condition for rated flow.
- Review spool overlap and command behavior during startup and switch-off.
- Confirm nominal size, subplate pattern, port and seal requirements.
- Match supply voltage, command input, connector and pin assignment.
- Review pilot supply, drain and feedback where the selected valve uses them.
- Approve the exact valve code, circuit drawing, quantity and documentation.

Selection, Documentation & Project Support

Selection Support
Learn more →Share your hydraulic circuit, operating point and installation requirements for a configuration discussion.
Flow · Pressure · Speed · Interfaces

Technical Resources
Learn more →Review product documentation, model codes and technical data before finalizing the specification.
Datasheets · Model codes · Drawings

Project Inquiries
Learn more →Send your required model, quantity, application and project requirements to discuss your inquiry.
Product inquiries · Configuration review
Configuration, Quantity & Delivery
Confirm the complete MS code, approved drawing and operating limits. Availability, quantity, documentation and delivery date are confirmed in the quotation.
Discuss Your 4WRAE Application
Send the full model code, operating duty, installation details and quantity.
Request a 4WRAE Quotation4WRAE Questions Before Ordering
What type of product is the 4WRAE?
4WRAE Direct Operated Proportional Valve. Design: Direct-operated proportional directional valve. Subplate-mounted direction and flow control. Confirm the complete order code for the offered version.
Can a similar valve replace the 4WRAE?
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits.
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits
Select the circuit symbol and required de-energized spool position. State working flow, pressure and the pressure-drop condition for rated flow. Attach the nameplate, complete order code, installation drawing and required quantity.
4WRAE Technical Data & Documents
View 4WRAE catalog data and operating conditions
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits.
Dados técnicos
(para aplicações fora destes parâmetros, por favor consulte-nos!)Geral
| Dimensão nominal | NS | 6 | 10 | |
| Instalação | opcional, de preferência horizontal | |||
| Gama de temperaturas de armazenamento | ℃ | -20 a +80 | ||
| Ambiente | 4WRA | ℃ | -20 a +70 | |
| gama de temperaturas | 4WRAE | ℃ | -20 a +50 | |
| Peso | 4WRA | kg | 2.0 | 6.6 |
| 4WRAE | kg | 2.2 | 6.8 | |
| Hidráulico (medido com HLP46, Θpetróleo= 40 ℃ ± 5 ℃) | ||||
| Pressão máx. de funcionamento | Portas A, B, P | bar | 315 | |
| Porto T | bar | 210 | ||
| Caudal nominal qV nom a Δp=10 bar | l/min | 7,15,26 | 30,60 | |
| Caudal máximo admissível | l/min | 42 (80)1) | 75 (140)1) | |
| Fluido sob pressão | mineral oil (HL, HLP) to DIN 51524 other pressure fluids on request! | |||
| Gama de temperaturas do fluido de pressão | ℃ | -20 a +80 (preferencialmente +40 a +50) | ||
| Gama de viscosidade | mm2/s | 20 a 380 (de preferência 30 a 46) | ||
| Classe de limpeza máxima admissível da contaminação do fluido sob pressão de acordo com a norma ISO 4406 (c) | classe 20/18/15 2) | |||
| Histerese | % | ≤ 5 | ||
| Erro de reversão | % | ≤ 1 | ||
| Sensibilidade de resposta | % | ≤ 0,5 | ||
Eléctrico
| Dimensão nominal | NS | 6 | 10 | |
| Tipo de tensão | DC | |||
| Sinal de valor de comando | Voltage input “A1” | V | ±10 | |
| com o tipo WRAE | Current input “F1” | mA | 4 a 20 | |
| Corrente máx. por solenoide | A | 2.5 | ||
| Bobina do solenoide | Valor a frio a 20 ℃ | Ω | 2 | |
| resistência | Valor máximo de aquecimento | Ω | 3 | |
| Dever | % | 100 | ||
| Temperatura máx. da bobina 1) | ℃ | 150 | ||
| Electrical connections see page 7 | 4WRA | com ficha de ligação segundo a norma DIN EN 175301-803 ou ISO 4400 | ||
| conector de ficha segundo a norma DIN EN 175301-803 ou ISO 4400 2) | ||||
| 4WRAE | com ficha de componentes conforme a DIN EN 175201-804 | |||
| conetor de ficha DIN EN 175201-804 2) | ||||
| Proteção da válvula conforme a EN 60529 | IP65 com conetor de encaixe montado e fixo | |||
Eletrónica de controlo
| Para 4WRA | Amplificador digital em formato Eurocard 2) | VT-VSPD-1-2X (to RE 30523 – middle of 2006) | |
| Amplificador analógico em formato Eurocard 2) | VT-VSPA2-1-2X/… to RE 30110 | ||
| amplificador de módulo analógico 2) | VT-MSPA2-1-1X para RE 30228 | ||
| Para 4WRAE | Módulo de valor de comando analógico | integrado nas válvulas, ver página 8 | |
| VT- SWMA-1-1X/… to RE 29902 | |||
| Módulo de valor de comando analógico | VT-SWMKA-1-1X/… to RE 29903 | ||
| placa de valor de comando digital | VT-HACD-1-1X/… to RE 30143 | ||
| Placa de valor de comando analógico | VT-SWKA-1-1X/… to RE 30255 | ||
| Supply voltage 4WRAE, 4WRA 3) | Tensão nominal | VDC | 24 |
| Valor limite inferior | V | 21 / 22 (4WRA); 19 (4WRAE) | |
| Valor limite superior | V | 35 | |
| Corrente do amplificador | lmáx | A | 1.8 |
| consumo | Corrente de impulso máx. | A | 3 |
Nota:
Para obter detalhes relativos ao teste de simulação ambiental que abrange a compatibilidade eletromagnética (EMC), o clima e a carga mecânica, consulte o documento RE 29055-U (declaração relativa à compatibilidade ambiental).Watch 4WRAE Product Video
Related Selection Resources
Request a 4WRAE Quotation
Tell us your required configuration, quantity and application.
Dados técnicos
(para aplicações fora destes parâmetros, por favor consulte-nos!)
Geral
| Dimensão nominal | NS | 6 | 10 | |
| Instalação | opcional, de preferência horizontal | |||
| Gama de temperaturas de armazenamento | ℃ | -20 a +80 | ||
| Ambiente | 4WRA | ℃ | -20 a +70 | |
| gama de temperaturas | 4WRAE | ℃ | -20 a +50 | |
| Peso | 4WRA | kg | 2.0 | 6.6 |
| 4WRAE | kg | 2.2 | 6.8 | |
| Hidráulico (medido com HLP46, Θpetróleo= 40 ℃ ± 5 ℃) | ||||
| Pressão máx. de funcionamento | Portas A, B, P | bar | 315 | |
| Porto T | bar | 210 | ||
| Caudal nominal qV nom a Δp=10 bar | l/min | 7,15,26 | 30,60 | |
| Caudal máximo admissível | l/min | 42 (80)1) | 75 (140)1) | |
| Fluido sob pressão | óleo mineral (HL, HLP) conforme a norma DIN 51524 outros fluidos sob pressão a pedido! |
|||
| Gama de temperaturas do fluido de pressão | ℃ | -20 a +80 (preferencialmente +40 a +50) | ||
| Gama de viscosidade | mm2/s | 20 a 380 (de preferência 30 a 46) | ||
| Classe de limpeza máxima admissível da contaminação do fluido sob pressão de acordo com a norma ISO 4406 (c) | classe 20/18/15 2) | |||
| Histerese | % | ≤ 5 | ||
| Erro de reversão | % | ≤ 1 | ||
| Sensibilidade de resposta | % | ≤ 0,5 | ||
1) caudal admissível com um trajeto de caudal duplo
2) A classe de limpeza especificada para os componentes deve ser cumprida nos sistemas hidráulicos. Uma filtragem eficaz evita a ocorrência de avarias e, ao mesmo tempo, aumenta a vida útil dos componentes. Para a seleção de filtros, consulte as folhas de catálogo RE 50070, RE 50076, RE 50081, RE 50086 e RE 50088.
Eléctrico
| Dimensão nominal | NS | 6 | 10 | |
| Tipo de tensão | DC | |||
| Sinal de valor de comando | Tensão de entrada "A1" | V | ±10 | |
| com o tipo WRAE | F1" | mA | 4 a 20 | |
| Corrente máx. por solenoide | A | 2.5 | ||
| Bobina do solenoide | Valor a frio a 20 ℃ | Ω | 2 | |
| resistência | Valor máximo de aquecimento | Ω | 3 | |
| Dever | % | 100 | ||
| Temperatura máx. da bobina 1) | ℃ | 150 | ||
| Ligações elétricas ver página 7 |
4WRA | com ficha de ligação segundo a norma DIN EN 175301-803 ou ISO 4400 | ||
| conector de ficha segundo a norma DIN EN 175301-803 ou ISO 4400 2) | ||||
| 4WRAE | com ficha de componentes conforme a DIN EN 175201-804 | |||
| conetor de ficha DIN EN 175201-804 2) | ||||
| Proteção da válvula conforme a EN 60529 | IP65 com conetor de encaixe montado e fixo | |||
Eletrónica de controlo
| Para 4WRA | Amplificador digital em formato Eurocard 2) | VT-VSPD-1-2X (para RE 30523 - meio de 2006) | |
| Amplificador analógico em formato Eurocard 2) | VT-VSPA2-1-2X/... para RE 30110 | ||
| amplificador de módulo analógico 2) | VT-MSPA2-1-1X para RE 30228 | ||
| Para 4WRAE | Módulo de valor de comando analógico | integrado nas válvulas, ver página 8 | |
| VT- SWMA-1-1X/... para RE 29902 | |||
| Módulo de valor de comando analógico | VT-SWMKA-1-1X/... para RE 29903 | ||
| placa de valor de comando digital | VT-HACD-1-1X/... para RE 30143 | ||
| Placa de valor de comando analógico | VT-SWKA-1-1X/... para RE 30255 | ||
| Tensão de alimentação 4WRAE, 4WRA 3) |
Tensão nominal | VDC | 24 |
| Valor limite inferior | V | 21 / 22 (4WRA); 19 (4WRAE) |
|
| Valor limite superior | V | 35 | |
| Corrente do amplificador | lmáx | A | 1.8 |
| consumo | Corrente de impulso máx. | A | 3 |
1) Devido à temperatura superficial gerada nas bobinas do solenoide, devem ser tidas em conta as Normas Europeias DIN EN 563 e DIN EN 982!
2) Separar pedido
3) Com eletrónica de controlo Bosch Rexroth AG
Nota:
Para obter detalhes relativos ao teste de simulação ambiental que abrange a compatibilidade eletromagnética (EMC), o clima e a carga mecânica, consulte o documento RE 29055-U (declaração relativa à compatibilidade ambiental).