Wenzhou Prance Hydraulic Equipment Co., Ltd.
4WREE Proportional Valve with Position Feedback
The 4WREE proportional valve combines direction and flow control with electrical spool-position feedback. The existing data distinguishes 4WRE and 4WREE variants, so electronics, weight and connection details must be selected from the correct variant.
- Electrical spool-position feedback
- Spring-centered spool
- Subplate mounting
- Sizes 6 and 10 distinguished in the table
PRANCE HYDRAULIC · PRODUCT SERIES
Proportional directional spool valve with electrical position feedback · Subplate-mounted flow and direction control
The 4WREE proportional valve combines direction and flow control with electrical spool-position feedback. The existing data distinguishes 4WRE and 4WREE variants, so electronics, weight and connection details must be selected from the correct variant.
Model

Confirm the complete model and approved specification with Prance Hydraulic. Product-series references alone do not establish interchangeability.
Configuration review · Technical documentation · Product selection
Detalles del producto
- Electrical spool-position feedback
- Spring-centered spool
- Subplate mounting
- Sizes 6 and 10 distinguished in the table
CATEGORIES: Válvula hidráulica, Válvula proporcional
4WREE Features & Application
Electrical spool-position feedback
Spool feedback concerns the valve position. Confirm whether the machine also requires separate actuator position or pressure feedback.
Spring-centered spool
Specify the full MS order code, installation drawing and operating duty so the quotation can identify the proposed configuration.
Subplate mounting
Check pilot diameter, bolt pattern, shaft engagement or port pattern against the approved installation drawing.
Sizes 6 and 10 distinguished in the table
Include the series and all order-code suffixes in the enquiry. A common nominal size does not establish compatibility.
4WREE Specifications
| Series / model | 4WREE |
|---|---|
| Product type | 4WREE Proportional Valve with Position Feedback |
| Diseño | Proportional directional spool valve with electrical position feedback |
| Circuit / selection | Subplate-mounted flow and direction control |
| Published nominal sizes | 6 and 10 |
| Feedback | Electrical spool position |
| Mounting pattern | DIN 24340 form A / ISO 4401 / CETOP reference in the existing description |
4WREE Selection & Configuration
The 4WREE proportional valve combines direction and flow control with electrical spool-position feedback. The existing data distinguishes 4WRE and 4WREE variants, so electronics, weight and connection details must be selected from the correct variant.
Confirm the command interface and connector pin assignment before replacing a valve. Spool-position feedback describes the valve control loop; it does not measure actuator position or eliminate the need to review the external machine controller.

cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits.
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits.
Hydraulic pumps · Hydraulic motors · Hydraulic valves
Send the MS nameplate, operating requirements and installation drawing for a configuration review before quoting.
- Model review — send the full model code or an existing nameplate photograph.
- Interface matching — confirm shaft, mounting flange, rotation and ports.
- Operating conditions — provide flow, pressure, speed, fluid and duty cycle.
- Documentation — request the relevant product data and drawings for your review.

4WREE Buying Guide
Use this sequence to prepare the 4WREE configuration for review and quotation.
- Select the circuit symbol and required de-energized spool position.
- State working flow, pressure and the pressure-drop condition for rated flow.
- Review spool overlap and command behavior during startup and switch-off.
- Confirm nominal size, subplate pattern, port and seal requirements.
- Match supply voltage, command input, connector and pin assignment.
- Review pilot supply, drain and feedback where the selected valve uses them.
- Approve the exact valve code, circuit drawing, quantity and documentation.

Selection, Documentation & Project Support

Selection Support
Learn more →Share your hydraulic circuit, operating point and installation requirements for a configuration discussion.
Flow · Pressure · Speed · Interfaces

Technical Resources
Learn more →Review product documentation, model codes and technical data before finalizing the specification.
Datasheets · Model codes · Drawings

Project Inquiries
Learn more →Send your required model, quantity, application and project requirements to discuss your inquiry.
Product inquiries · Configuration review
Configuration, Quantity & Delivery
Confirm the complete MS code, approved drawing and operating limits. Availability, quantity, documentation and delivery date are confirmed in the quotation.
Discuss Your 4WREE Application
Send the full model code, operating duty, installation details and quantity.
Request a 4WREE Quotation4WREE Questions Before Ordering
What type of product is the 4WREE?
4WREE Proportional Valve with Position Feedback. Design: Proportional directional spool valve with electrical position feedback. Subplate-mounted flow and direction control. Confirm the complete order code for the offered version.
Can a similar valve replace the 4WREE?
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits.
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits
Select the circuit symbol and required de-energized spool position. State working flow, pressure and the pressure-drop condition for rated flow. Attach the nameplate, complete order code, installation drawing and required quantity.
4WREE Technical Data & Documents
View 4WREE catalog data and operating conditions
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits.
Datos técnicos ¡Para aplicaciones fuera de estos parámetros, consúltenos!
General
| Tallas | Tamaño | 6 | 10 | |
| Peso | – Type 4WRE | kg | 2.2 | 6.3 |
| – Type 4WREE | kg | 2.4 | 6.5 | |
| Posición de instalación | Cualquiera, preferiblemente horizontal | |||
| Rango de temperatura ambiente | – Type 4WRE | ℃ | -20 a +70 | |
| – Type 4WREE | ℃ | -20 a +50 | ||
| Rango de temperatura de almacenamiento | ℃ | -20 a +80 | ||
| MTTFd valores según la norma EN ISO 13849 | Años | 150 1) (para más información consulte la hoja de datos 08012) | ||
hidráulico (medido con HLP46, θaceite=40 ℃ + 5 ℃ y p = 100 bar)
| Maximum operating pressure | – Port A,B,P | bar | 315 | |
| – Port T | bar | 210 | ||
| Caudal nominal qPara mayores de 17 años con Δp = 10 bar | l/min | 4,8,16,32 | 25,50,75 | |
| Caudal máximo recomendado | l/min | 80 | 180 | |
| Fluido hidráulico | Ver tabla a continuación | |||
| Rango de temperatura del fluido hidráulico | ℃ | -20 a +80 (preferiblemente de +40 a +50) | ||
| Rango de viscosidad | mm2/s | 20 a 380 (preferiblemente 30 a 46) | ||
| Grado máximo admisible de contaminación del fluido hidráulico, clase de limpieza según ISO 4406 (c) | Clase 20/18/15 2) | |||
| Histéresis | % | ≤ 1 | ||
| Rango de inversión | % | ≤ 0,05 | ||
| Sensibilidad de respuesta | % | ≤ 0,05 | ||
| Desplazamiento de cero al cambiar el sistema hidráulico | %/10K | ≤ 0,15 | ||
| temperatura del fluido y presión de operación | %/100 barra | ≤ 0,1 | ||
| Fluido hidráulico | Clasificación | Suitable sealing materials | Estándares | |
| Aceites minerales y hidrocarburos relacionados | HL, HLP | NBR, FKM | DIN 51524 | |
| Resistente a las llamas | que contiene agua | HFC (Fuchs HYDROTHERM 46M, Petrofer Ultra Safe 620) | NBR | ISO 12922 |
| Important information on hydraulic fluids! -For more information and data on the use of other hydraulic fluids refer to data sheet 90220 or contact us! -There may be limitations regarding the technical valve data (temperature, pressure range, service life , maintenance intervals, etc.)! -The flash point of the process and operating medium used must be 40 K higher than the maximum solenoid surface temperature. – Flame-resistant- wate-containingr: Maximum pressure differential per control edge 175 bar. Pressure pre-loading at the tank port > 20% of the pressure differential; otherwise, increased cavitation. Life cycle as compared to operation with mineral oil HL,HLP 50% to 100% | ||||
Eléctrico
| Tamaño | Tamaño | 6 | 6 | |
| Tipo de voltaje | Tensión continua | |||
| Bobina de solenoide | – Cold value at 20 ℃ | Ω | 2.65 | 4.55 |
| resistencia | Valor máximo de temperatura alta | Ω | 4.05 | 6.82 |
| Ciclo de trabajo | % | 100 | ||
| Temperatura máxima de la bobina 1) | ℃ | hasta 150 | ||
| Electrical connection see page 8 and 9 | – Type 4WRE | Con conector según DIN EN 175301-803 e ISO 4400 | ||
| Conector hembra según DIN EN 175301-803 e ISO 4400 2) | ||||
| – Type 4WREE | Con conector DIN EN 175201-804 | |||
| Conector hembra DIN EN 175201-804 2) IP65 con el conector acoplado, montado y bloqueado | ||||
| Clase de protección de la válvula según EN 60529 | IP65 con el conector acoplado, montado y bloqueado | |||
Electrónica de control
| Tipo 4WRE | versión 4/3 | Digital | VT-VRPD-2-2X/V0/0 según RE 30126 | |
| Amplificador en | ||||
| formato tarjeta euro 2) | Análogo | VT-VRPA2-1-1X/V0 according to data sheet 30119 | VT-VRPA2-2-1X/VO según la hoja de datos 30119 | |
| Módulo amplificador 2) | Análogo | VT-MRPA2-1 according to data sheet 30219 | VT-MRPA2-2 según la hoja de datos 30219 | |
| Type 4WRE…A… | versión 4/2 | Análogo | cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits | VT-MRPA1-2 según la hoja de datos 30219 |
| Módulo amplificador 2) | ||||
| Tipo 4WREE | módulo de valor de comando analógico | Integrado en la válvula, ver página 9 | ||
| cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits | ||||
| módulo de valor de comando analógico | cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits | |||
| tarjeta de valor de comando analógico | cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits | |||
| tarjeta de valor de comando digital | cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits | |||
| Tensión de alimentación | Tensión nominal | VDC | 24 | |
| valor de límite inferior | V | 19.4 | ||
| valor límite superior | V | 35 | ||
| Consumo de corriente | Imáx | A | <2 | |
| del amplificador | Corriente pulsada | A | 3 | |
Aviso:
Para obtener información sobre las pruebas de simulación ambiental para las áreas de CEM (compatibilidad electromagnética), clima y carga mecánica, consulte la hoja de datos 29061-U (declaración sobre compatibilidad ambiental).cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits
Related Selection Resources
Request a 4WREE Quotation
Tell us your required configuration, quantity and application.
Datos técnicos ¡Para aplicaciones fuera de estos parámetros, consúltenos!
General
| Tallas | Tamaño | 6 | 10 | |
| Peso | - Tipo 4WRE | kg | 2.2 | 6.3 |
| - Tipo 4WREE | kg | 2.4 | 6.5 | |
| Posición de instalación | Cualquiera, preferiblemente horizontal | |||
| Rango de temperatura ambiente | - Tipo 4WRE | ℃ | -20 a +70 | |
| - Tipo 4WREE | ℃ | -20 a +50 | ||
| Rango de temperatura de almacenamiento | ℃ | -20 a +80 | ||
| MTTFd valores según la norma EN ISO 13849 | Años | 150 1) (para más información consulte la hoja de datos 08012) | ||
hidráulico (medido con HLP46, θaceite=40 ℃ + 5 ℃ y p = 100 bar)
| Funcionamiento máximo presión |
- Puerto A, B, P | bar | 315 | |
| - Puerto T | bar | 210 | ||
| Caudal nominal qPara mayores de 17 años con Δp = 10 bar | l/min | 4,8,16,32 | 25,50,75 | |
| Caudal máximo recomendado | l/min | 80 | 180 | |
| Fluido hidráulico | Ver tabla a continuación | |||
| Rango de temperatura del fluido hidráulico | ℃ | -20 a +80 (preferiblemente de +40 a +50) | ||
| Rango de viscosidad | mm2/s | 20 a 380 (preferiblemente 30 a 46) | ||
| Grado máximo admisible de contaminación del fluido hidráulico, clase de limpieza según ISO 4406 (c) | Clase 20/18/15 2) | |||
| Histéresis | % | ≤ 1 | ||
| Rango de inversión | % | ≤ 0,05 | ||
| Sensibilidad de respuesta | % | ≤ 0,05 | ||
| Desplazamiento de cero al cambiar el sistema hidráulico | %/10K | ≤ 0,15 | ||
| temperatura del fluido y presión de operación | %/100 barra | ≤ 0,1 | ||
1)Con los tipos de carrete de control E, E1, EA, W, W1, WA; en la dirección longitudinal del carrete de control, hay un solape positivo suficiente sin carga de choque/vibración; observe la orientación de instalación con respecto a la dirección principal de aceleración.
2) En los sistemas hidráulicos se deben respetar las clases de limpieza especificadas para los componentes. Una filtración eficaz evita averías y, al mismo tiempo, aumenta la vida útil de los componentes.
| Fluido hidráulico | Clasificación | Adecuado materiales de sellado |
Estándares | |
| Aceites minerales y hidrocarburos relacionados | HL, HLP | NBR, FKM | DIN 51524 | |
| Resistente a las llamas | que contiene agua | HFC (Fuchs HYDROTHERM 46M, Petrofer Ultra Safe 620 |
NBR | ISO 12922 |
| ¡Información importante sobre los fluidos hidráulicos! -Para obtener más información y datos sobre el uso de otros fluidos hidráulicos, consulte la hoja de datos 90220 o ¡póngase en contacto con nosotros! -¡Puede haber limitaciones con respecto a los datos técnicos de la válvula (temperatura, rango de presión, vida útil, intervalos de mantenimiento, etc.)! El punto de inflamación del proceso y del medio de operación utilizado debe ser 40 K superior a la temperatura máxima de la superficie del solenoide. - Resistente al fuego y con contenido de agua: diferencia de presión máxima por borde de control: 175 bar. Precarga de presión en la toma del depósito > 20% de la diferencia de presión; de lo contrario, se producirá una mayor cavitación. Ciclo de vida en comparación con el funcionamiento con aceite mineral HL, HLP 50% a 100% |
||||
Eléctrico
| Tamaño | Tamaño | 6 | 6 | |
| Tipo de voltaje | Tensión continua | |||
| Bobina de solenoide | - Valor en frío a 20 ℃ | Ω | 2.65 | 4.55 |
| resistencia | Valor máximo de temperatura alta | Ω | 4.05 | 6.82 |
| Ciclo de trabajo | % | 100 | ||
| Temperatura máxima de la bobina 1) | ℃ | hasta 150 | ||
| Conexión eléctrica ver la página 8 y 9 |
- Tipo 4WRE | Con conector según DIN EN 175301-803 e ISO 4400 | ||
| Conector hembra según DIN EN 175301-803 e ISO 4400 2) | ||||
| - Tipo 4WREE | Con conector DIN EN 175201-804 | |||
| Conector hembra DIN EN 175201-804 2) IP65 con el conector acoplado, montado y bloqueado |
||||
| Clase de protección de la válvula según EN 60529 | IP65 con el conector acoplado, montado y bloqueado | |||
Electrónica de control
| Tipo 4WRE | versión 4/3 | Digital | VT-VRPD-2-2X/V0/0 según RE 30126 | |
| Amplificador en | ||||
| formato tarjeta euro 2) | Análogo | VT-VRPA2-1-1X/V0 según la hoja de datos 30119 |
VT-VRPA2-2-1X/VO según la hoja de datos 30119 | |
| Módulo amplificador 2) | Análogo | VT-MRPA2-1 según la hoja de datos 30219 |
VT-MRPA2-2 según la hoja de datos 30219 | |
| Tipo 4WRE...A... | versión 4/2 | Análogo | VT-MRPA1-1 según la hoja de datos 30219 |
VT-MRPA1-2 según la hoja de datos 30219 |
| Módulo amplificador 2) | ||||
| Tipo 4WREE | módulo de valor de comando analógico | Integrado en la válvula, ver página 9 | ||
| VT- SWMA-1-1X/...según la hoja de datos 29902 | ||||
| módulo de valor de comando analógico | VT-SWMAK-1-1X/... según la hoja de datos 29903 | |||
| tarjeta de valor de comando analógico | VT-SWKA-1-1X/... según la hoja de datos 30255 | |||
| tarjeta de valor de comando digital | VT-HACD -1-1X/... según la hoja de datos 30143 | |||
| Tensión de alimentación | Tensión nominal | VDC | 24 | |
| valor de límite inferior | V | 19.4 | ||
| valor límite superior | V | 35 | ||
| Consumo de corriente | Imáx | A | <2 | |
| del amplificador | Corriente pulsada | A | 3 | |
1)Debido a las temperaturas que se producen en las superficies de las bobinas de los solenoides, es necesario cumplir con las normas europeas ISO 13732-1 y EN ISO 4413.
2) Pedido separado
Aviso:
Para obtener información sobre las pruebas de simulación ambiental para las áreas de CEM (compatibilidad electromagnética), clima y carga mecánica, consulte la hoja de datos 29061-U (declaración sobre compatibilidad ambiental).