Wenzhou Prance Hydraulic Equipment Co., Ltd
A10VNO Open Circuit Variable Piston Pump
The A10VNO variable displacement pump uses a swashplate rotary group for open-circuit systems. Its existing technical table separates inlet, outlet and case-drain limits, which must be checked together at the intended pressure and speed.
- Swashplate displacement adjustment
- Open-circuit drive
- Pressure and flow control
- Separate inlet and case-drain limits
PRANCE HYDRAULIC · PRODUCT SERIES
Axial piston; variable swashplate · Open circuit
The A10VNO variable displacement pump uses a swashplate rotary group for open-circuit systems. Its existing technical table separates inlet, outlet and case-drain limits, which must be checked together at the intended pressure and speed.
Model
-2.webp)
Confirm the complete model and approved specification with Prance Hydraulic. Product-series references alone do not establish interchangeability.
Configuration review · Technical documentation · Product selection
Detalhes do Produto
- Swashplate displacement adjustment
- Open-circuit drive
- Pressure and flow control
- Separate inlet and case-drain limits
CATEGORIES: Bomba de pistão, Bomba de caudal variável
A10VNO Features & Application
Swashplate displacement adjustment
Specify the full MS order code, installation drawing and operating duty so the quotation can identify the proposed configuration.
Open-circuit drive
Review normal running, startup and reversal where applicable. The pressure and flow requirements can differ between operating states.
Pressure and flow control
Match the complete control option and its command requirements to the existing controller. Similar housings can use different control arrangements.
Separate inlet and case-drain limits
Keep continuous, intermittent and peak conditions separate. Use the row for the selected size and configuration.
A10VNO Specifications
| Series / model | A10VNO |
|---|---|
| Product type | A10VNO Open Circuit Variable Piston Pump |
| Design | Axial piston; variable swashplate |
| Circuit / selection | Open circuit |
| Published nominal sizes | 28, 45, 63 and 85 |
| Listed nominal outlet pressure | 210 bar; verify selected configuration |
| Listed peak outlet pressure | 250 bar; confirm duty limitations |
A10VNO Selection & Configuration
The A10VNO variable displacement pump uses a swashplate rotary group for open-circuit systems. Its existing technical table separates inlet, outlet and case-drain limits, which must be checked together at the intended pressure and speed.
A suitable outlet-pressure rating does not compensate for an unsuitable suction or drain line. Provide reservoir position, suction losses and the drain route, then confirm the pressure/flow control and interface options for the selected size.
-1.webp)
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits.
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits.
Hydraulic pumps · Hydraulic motors · Hydraulic valves
Send the MS nameplate, operating requirements and installation drawing for a configuration review before quoting.
- Model review — send the full model code or an existing nameplate photograph.
- Interface matching — confirm shaft, mounting flange, rotation and ports.
- Operating conditions — provide flow, pressure, speed, fluid and duty cycle.
- Documentation — request the relevant product data and drawings for your review.

A10VNO Buying Guide
Use this sequence to prepare the A10VNO configuration for review and quotation.
- Define required flow at the actual drive speed and continuous pressure.
- Identify peak pressure, duration and the work cycle.
- Confirm the selected displacement control and any auxiliary-drive requirement.
- Match rotation viewed from the shaft end, shaft, flange and ports.
- Review inlet conditions, drain routing and the installation envelope.
- Confirm fluid, viscosity, temperature, filtration and seals.
- Approve the complete model, control, drawing, quantity and delivery terms.
-5.webp)
Selection, Documentation & Project Support

Selection Support
Learn more →Share your hydraulic circuit, operating point and installation requirements for a configuration discussion.
Flow · Pressure · Speed · Interfaces

Technical Resources
Learn more →Review product documentation, model codes and technical data before finalizing the specification.
Datasheets · Model codes · Drawings

Project Inquiries
Learn more →Send your required model, quantity, application and project requirements to discuss your inquiry.
Product inquiries · Configuration review
Configuration, Quantity & Delivery
Confirm the complete MS code, approved drawing and operating limits. Availability, quantity, documentation and delivery date are confirmed in the quotation.
Discuss Your A10VNO Application
Send the full model code, operating duty, installation details and quantity.
Request a A10VNO QuotationA10VNO Questions Before Ordering
What type of product is the A10VNO?
A10VNO Open Circuit Variable Piston Pump. Design: Axial piston; variable swashplate. Open circuit. Confirm the complete order code for the offered version.
Can a similar pump replace the A10VNO?
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits.
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits
Define required flow at the actual drive speed and continuous pressure. Identify peak pressure, duration and the work cycle. Attach the nameplate, complete order code, installation drawing and required quantity.
A10VNO Technical Data & Documents
View A10VNO catalog data and operating conditions
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits.
Dados técnicos
Gama de pressões de funcionamento, entrada
Absolute pressure at port S Pmín abs—————————12 psi (0,8 bar) Pmáx. abs.—————————73 psi (5 bar)Gama de pressões de funcionamento, saída
Pressure at port B Nominal pressure PN—————3000 psi (210 bar) Peak pressure Pmasx——————3600 psi (250 bar) (Pressures to DIN 24312)Sentido do fluxo
S para Bpressão de dreno da caixa
Maximum permissible case drain pressure (port Lx): maximum 7 psi (0,5 bar) higher than the inlet pressure at port S, however not higher than 29 psi (2 bar) absolute. PLabs max—————————29 psi (2 bar)Tabela de valores (valores teóricos, sem considerar eficiências e tolerâncias; valores arredondados)
| Tamanho | 28 | 45 | 63 | 85 | |||
| Deslocamento | Vg máx | em3 (cm3) | 1.71(28) | 2.75 (45) | 3.84(63) | 5.19(85) | |
| Velocidade2) | |||||||
| máx. às VG Max | n0 máx 11) | min-1 | 3200 | 2900 | 2700 | 2700 | |
| às n0 máximo | qv0 máx 11) | gpm | 23.8 | 34.6 | 45 | 60.8 | |
| (l/min) | (90) | (131) | (170) | (230) | |||
| às n0 máximo | P0 máx 11) | CV (kW) | 42 (31) | 62(46) | 79 (59) | 107 (80) | |
| às VG Max | Tmáx | lb-ft (Nm) | 69 (94) | 110 (150) | 155 (210) | 209 (284) | |
| Rigidez torcional | extremidade do veio R | c | lb-ft/rad (Nm/rad) | 10882 | 19480 | 29770 | 51029 |
| (14800) | (26500) | (40500) | (69400) | ||||
| Momento de inércia do grupo rotativo | JTW | lb-ft/rad (kgm2) | 0.0403 | 0.0474 | 0.0949 | 0.423 | |
| (0,001) | (0,002) | (0,004) | (0,006) | ||||
| Aceleração angular, máx.2) | α | rad/s2 | 6800 | 4900 | 3500 | 2500 | |
| Volume de processos | V | gal(L) | 0.08 (0,25) | 0.08 (0,3) | 0.13 (0,5) | 0.21 (0,8) | |
| Peso (com controlo de press.) | m | lb (kg) | 25.3 (11,5) | 31 (14) | 39.7 (18) | 48.5 (22) | |
Determinação do tamanho da bomba
Carga radial e axial admissível no veio de acionamento
| Tamanho | 28 | 45 | 63 | 85 | ||||
| Força radial, máx. | ![]() |
em X/2 | Fque máximo | lbf | 79 | 146 | 225 | 303 |
| (N) | (350) | (650) | (1000) | (1350) | ||||
| Força axial, máx. | ![]() |
Fmachado | lbf | 157,4 | 146 | 225 | 303 | |
| (N) | (700) | (650) | (1000) | (1350) | ||||
Watch A10VNO Product Video
Related Selection Resources
Request a A10VNO Quotation
Tell us your required configuration, quantity and application.
Código de encomenda - Programa padrão
| A10VN | ○ | DRS | / | 5x | - | V | R | C | N00 | |||
| 01 | 02 | 03 | 04 | 05 | 06 | 07 | 08 | 09 | 10 | 11 |
Unidade de pistões axiais
| 01 | Conceito de prato oscilante, variável, pressão nominal de 210 bar, pressão de pico de 250 bar | A10VN |
Tipo de operação
| 02 | Bomba de circuito aberto | ○ |
Tamanho
| 28 | 45 | 63 | 85 | |||
| 03 | ~Cilindrada VG Max em | em3 | 1.71 | 2.75 | 3.84 | 5.19 |
| cm3 | 28 | 45 | 63 | 85 |
Dispositivo de controlo
| 04 | Controlo de pressão | |
| com controlo de caudal, hidráulico, X-T fechado | DRS | |
Séries
| 05 | Série 5 | Índice 2 | - | ● | ● | - | 52 |
| Índice 3 | ● | - | - | ● | 53 |
Sentido de rotação
| 06 | Visto da extremidade do eixo | mão direita | R |
| mão esquerda | L |
Focas
| 07 | FKM (Borracha fluorada) | V |
Extremidade do veio
| 08 | Com estrias conforme a norma SAE J744 | R |
Flange de montagem
| 09 | furação SAE de 2 furos | c |
Portos para linhas de serviço
| 10 | orifícios roscados ISO 6149-1 na retaguarda, métricos | - | ● | - | - | 40 |
| orifícios de flange SAE na traseira, furos de parafusos métricos | ● | - | ● | ● | 11 |
Dados técnicos
Gama de pressões de funcionamento, entrada
Pressão absoluta no orifício S
Pmín abs---------------------------12 psi (0,8 bar)
Pmáx. abs.---------------------------73 psi (5 bar)
Gama de pressões de funcionamento, saída
Pressão na porta B
Pressão nominal PN---------------3000 psi (210 bar)
Pressão de pico Pmasx------------------3600 psi (250 bar)
(Pressões conforme DIN 24312)
Sentido do fluxo
S para B
pressão de dreno da caixa
Pressão máxima admissível na linha de dreno da carcaça (orifício Lx):
no máximo 7 psi (0,5 bar) superior à pressão de entrada na porta S, contudo não superior a 29 psi (2 bar) absoluto.
PLabs max---------------------------29 psi (2 bar)
Tabela de valores (valores teóricos, sem considerar eficiências e tolerâncias; valores arredondados)
| Tamanho | 28 | 45 | 63 | 85 | |||
| Deslocamento | Vg máx | em3 (cm3) | 1.71(28) | 2.75 (45) | 3.84(63) | 5.19(85) | |
| Velocidade2) | |||||||
| máx. às VG Max | n0 máx 11) | min-1 | 3200 | 2900 | 2700 | 2700 | |
| Fluxo | |||||||
| às n0 máximo | qv0 máx 11) | gpm | 23.8 | 34.6 | 45 | 60.8 | |
| (l/min) | (90) | (131) | (170) | (230) | |||
| Energia | Δp= 3000 psi (210 bar) | ||||||
| às n0 máximo | P0 máx 11) | CV (kW) | 42 (31) | 62(46) | 79 (59) | 107 (80) | |
| Binário | Δp= 3000 psi (210 bar) | ||||||
| às VG Max | Tmáx | lb-ft (Nm) | 69 (94) | 110 (150) | 155 (210) | 209 (284) | |
| Rigidez torcional | extremidade do veio R | c | lb-ft/rad
(Nm/rad) |
10882 | 19480 | 29770 | 51029 |
| (14800) | (26500) | (40500) | (69400) | ||||
| Momento de inércia do grupo rotativo | JTW | lb-ft/rad
(kg/m²) |
0.0403 | 0.0474 | 0.0949 | 0.423 | |
| (0,001) | (0,002) | (0,004) | (0,006) | ||||
| Aceleração angular, máx.2) | α | rad/s2 | 6800 | 4900 | 3500 | 2500 | |
| Volume de processos | V | gal(L) | 0.08 (0,25) | 0.08 (0,3) | 0.13 (0,5) | 0.21 (0,8) | |
| Peso (com controlo de press.) | m | lb (kg) | 25.3 (11,5) | 31 (14) | 39.7 (18) | 48.5 (22) | |
1)autoescorvante com pressão absoluta de 15 psi (1 bar) na porta de admissão S
2) -Estes valores são válidos para condições entre as velocidades de acionamento mín. exigidas e as máx. admissíveis.
Para fontes externas de excitação (por exemplo, frequência rotacional de 2 a 8 vezes do motor Diesel, frequência rotacional de 2 vezes do veio de cardã).
-O limite é válido para uma única bomba.
-A capacidade de carga das peças de ligação deve ser tida em consideração.
Atenção: Exceder estes limites pode resultar numa perda de operacionalidade, numa redução da vida útil ou na destruição completa da unidade de pistões axiais.
Os valores admissíveis podem ser calculados
Determinação do tamanho da bomba
| Fluxo | qv=(Vg ∙ n ∙ ηv) /231(1000) | gpm (L/min) |
| Binário | M=(Vg ∙ Δp) / 24(20) ∙ π ∙ ηmh | lb-pé (Nm) |
| Energia | P=(2π ∙ M ∙ n)/33000(60000)=(qv ∙ p)/[1714(600) ∙ ηt] | CV (kW) |
Vgdeslocamento geométrico por rotação em pol³3 (cm3)
p = diferencial de pressão em psi (bar)
n = velocidade do acionamento em rpm
ηv = eficiência volumétrica
ηmh= eficiência mecânico-hidráulica
ηt= eficiência global (ηt= ηv*ηmh)
Carga radial e axial admissível no veio de acionamento
| Tamanho | 28 | 45 | 63 | 85 | ||||
| Força radial, máx. | ![]() |
em X/2 | Fque máximo | lbf | 79 | 146 | 225 | 303 |
| (N) | (350) | (650) | (1000) | (1350) | ||||
| Força axial, máx. | ![]() |
Fmachado | lbf | 157,4 | 146 | 225 | 303 | |
| (N) | (700) | (650) | (1000) | (1350) | ||||

-3.webp)
-4.webp)
-6.webp)



-2.webp)

-2-1.webp)