Wenzhou Prance Hydraulic Equipment Co., Ltd.
A10VNO Open Circuit Variable Piston Pump
The A10VNO variable displacement pump uses a swashplate rotary group for open-circuit systems. Its existing technical table separates inlet, outlet and case-drain limits, which must be checked together at the intended pressure and speed.
- Swashplate displacement adjustment
- Open-circuit drive
- Pressure and flow control
- Separate inlet and case-drain limits
PRANCE HYDRAULIC · PRODUCT SERIES
Axial piston; variable swashplate · Open circuit
The A10VNO variable displacement pump uses a swashplate rotary group for open-circuit systems. Its existing technical table separates inlet, outlet and case-drain limits, which must be checked together at the intended pressure and speed.
Model
-2.webp)
Confirm the complete model and approved specification with Prance Hydraulic. Product-series references alone do not establish interchangeability.
Configuration review · Technical documentation · Product selection
Detalles del producto
- Swashplate displacement adjustment
- Open-circuit drive
- Pressure and flow control
- Separate inlet and case-drain limits
CATEGORIES: Bomba de pistón, Bomba de desplazamiento variable
A10VNO Features & Application
Swashplate displacement adjustment
Specify the full MS order code, installation drawing and operating duty so the quotation can identify the proposed configuration.
Open-circuit drive
Review normal running, startup and reversal where applicable. The pressure and flow requirements can differ between operating states.
Pressure and flow control
Match the complete control option and its command requirements to the existing controller. Similar housings can use different control arrangements.
Separate inlet and case-drain limits
Keep continuous, intermittent and peak conditions separate. Use the row for the selected size and configuration.
A10VNO Specifications
| Series / model | A10VNO |
|---|---|
| Product type | A10VNO Open Circuit Variable Piston Pump |
| Diseño | Axial piston; variable swashplate |
| Circuit / selection | Open circuit |
| Published nominal sizes | 28, 45, 63 and 85 |
| Listed nominal outlet pressure | 210 bar; verify selected configuration |
| Listed peak outlet pressure | 250 bar; confirm duty limitations |
A10VNO Selection & Configuration
The A10VNO variable displacement pump uses a swashplate rotary group for open-circuit systems. Its existing technical table separates inlet, outlet and case-drain limits, which must be checked together at the intended pressure and speed.
A suitable outlet-pressure rating does not compensate for an unsuitable suction or drain line. Provide reservoir position, suction losses and the drain route, then confirm the pressure/flow control and interface options for the selected size.
-1.webp)
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits.
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits.
Hydraulic pumps · Hydraulic motors · Hydraulic valves
Send the MS nameplate, operating requirements and installation drawing for a configuration review before quoting.
- Model review — send the full model code or an existing nameplate photograph.
- Interface matching — confirm shaft, mounting flange, rotation and ports.
- Operating conditions — provide flow, pressure, speed, fluid and duty cycle.
- Documentation — request the relevant product data and drawings for your review.

A10VNO Buying Guide
Use this sequence to prepare the A10VNO configuration for review and quotation.
- Define required flow at the actual drive speed and continuous pressure.
- Identify peak pressure, duration and the work cycle.
- Confirm the selected displacement control and any auxiliary-drive requirement.
- Match rotation viewed from the shaft end, shaft, flange and ports.
- Review inlet conditions, drain routing and the installation envelope.
- Confirm fluid, viscosity, temperature, filtration and seals.
- Approve the complete model, control, drawing, quantity and delivery terms.
-5.webp)
Selection, Documentation & Project Support

Selection Support
Learn more →Share your hydraulic circuit, operating point and installation requirements for a configuration discussion.
Flow · Pressure · Speed · Interfaces

Technical Resources
Learn more →Review product documentation, model codes and technical data before finalizing the specification.
Datasheets · Model codes · Drawings

Project Inquiries
Learn more →Send your required model, quantity, application and project requirements to discuss your inquiry.
Product inquiries · Configuration review
Configuration, Quantity & Delivery
Confirm the complete MS code, approved drawing and operating limits. Availability, quantity, documentation and delivery date are confirmed in the quotation.
Discuss Your A10VNO Application
Send the full model code, operating duty, installation details and quantity.
Request a A10VNO QuotationA10VNO Questions Before Ordering
What type of product is the A10VNO?
A10VNO Open Circuit Variable Piston Pump. Design: Axial piston; variable swashplate. Open circuit. Confirm the complete order code for the offered version.
Can a similar pump replace the A10VNO?
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits.
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits
Define required flow at the actual drive speed and continuous pressure. Identify peak pressure, duration and the work cycle. Attach the nameplate, complete order code, installation drawing and required quantity.
A10VNO Technical Data & Documents
View A10VNO catalog data and operating conditions
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits.
Datos técnicos
Rango de presión de operación, entrada
Absolute pressure at port S Pmínimo absoluto—————————12 psi (0,8 bar) Pmáximo absoluto—————————73 psi (5 bar)Rango de presión de operación, salida
Pressure at port B Nominal pressure PN—————3000 psi (210 bar) Peak pressure Pmadrex——————3600 psi (250 bar) (Pressures to DIN 24312)Dirección del flujo
De S a BPresión de drenaje de la caja
Maximum permissible case drain pressure (port Lx): maximum 7 psi (0,5 bar) higher than the inlet pressure at port S, however not higher than 29 psi (2 bar) absolute. PLaboratorios máx—————————29 psi (2 bar)Tabla de valores (valores teóricos, sin considerar eficiencias y tolerancias; valores redondeados)
| Tamaño | 28 | 45 | 63 | 85 | |||
| Desplazamiento | Vg máx | en3 (cm3) | 1.71(28) | 2.75 (45) | 3.84(63) | 5.19(85) | |
| Velocidad2) | |||||||
| máx. a VG máximo | n0 máx 11) | mín-1 | 3200 | 2900 | 2700 | 2700 | |
| en y0 máx | qv0 máx 11) | gpm | 23.8 | 34.6 | 45 | 60.8 | |
| (L/min) | (90) | (131) | (170) | (230) | |||
| en y0 máx | P0 máx 11) | HP(kW) | 42 (31) | 62(46) | 79 (59) | 107 (80) | |
| a las VG máximo | Tmáx | lb-pie (Nm) | 69 (94) | 110 (150) | 155 (210) | 209 (284) | |
| Rigidez torsional | extremo del eje R | c | lb-ft/rad (Nm/rad) | 10882 | 19480 | 29770 | 51029 |
| (14800) | (26500) | (40500) | (69400) | ||||
| Momento de inercia del grupo rotatorio | JTW | lb-ft/rad (kgm2) | 0.0403 | 0.0474 | 0.0949 | 0.423 | |
| (0,001) | (0,002) | (0,004) | (0,006) | ||||
| Aceleración angular, máx.2) | α | rad/s2 | 6800 | 4900 | 3500 | 2500 | |
| Volumen de casos | V | gal(L) | 0.08 (0,25) | 0.08 (0,3) | 0.13 (0,5) | 0.21 (0,8) | |
| Peso (con control de pres.) | m | libras (kg) | 25.3 (11,5) | 31 (14) | 39.7 (18) | 48.5 (22) | |
Determinación del tamaño de la bomba
Carga radial y axial permisible en el eje de transmisión
| Tamaño | 28 | 45 | 63 | 85 | ||||
| Fuerza radial, máx. | ![]() |
en X/2 | Fcuántos máximos | libra | 79 | 146 | 225 | 303 |
| (N) | (350) | (650) | (1000) | (1350) | ||||
| Fuerza axial, máx. | ![]() |
Fhacha | libra | 157,4 | 146 | 225 | 303 | |
| (N) | (700) | (650) | (1000) | (1350) | ||||
Watch A10VNO Product Video
Related Selection Resources
Request a A10VNO Quotation
Tell us your required configuration, quantity and application.
Código de pedido - Programa estándar
| A10VN | ○ | DRS | / | 5x | - | V | R | C | N00 | |||
| 01 | 02 | 03 | 04 | 05 | 06 | 07 | 08 | 09 | 10 | 11 |
Unidad de pistones axiales
| 01 | Diseño de plato oscilante, variable, presión nominal 210 bar, presión de pico 250 bar | A10VN |
Tipo de operación
| 02 | Bomba de circuito abierto | ○ |
Tamaño
| 28 | 45 | 63 | 85 | |||
| 03 | ~Desplazamiento VG máximo en | en3 | 1.71 | 2.75 | 3.84 | 5.19 |
| cm3 | 28 | 45 | 63 | 85 |
Dispositivo de control
| 04 | Control de presión | |
| con control de flujo, hidráulico, X-T cerrado | DRS | |
Series
| 05 | Serie 5 | Índice 2 | - | ● | ● | - | 52 |
| Índice 3 | ● | - | - | ● | 53 |
Sentido de giro
| 06 | Vista desde el extremo del eje | mano derecha | R |
| mano izquierda | L |
Focas
| 07 | FKM (caucho fluorado) | V |
Extremo del eje
| 08 | Acanalado según SAE J744 | R |
Brida de montaje
| 09 | brida SAE de 2 agujeros | c |
Puertos para líneas de servicio
| 10 | puertos roscados ISO 6149-1 en la parte trasera, métricos | - | ● | - | - | 40 |
| puertos de brida SAE en la parte trasera, agujeros para pernos métricos | ● | - | ● | ● | 11 |
Datos técnicos
Rango de presión de operación, entrada
Presión absoluta en el puerto S
Pmínimo absoluto---------------------------12 psi (0,8 bar)
Pmáximo absoluto---------------------------73 psi (5 bar)
Rango de presión de operación, salida
Presión en el puerto B
Presión nominal PN---------------3000 psi (210 bar)
Presión máxima Pmadrex------------------3600 psi (250 bar)
(Presiones según DIN 24312)
Dirección del flujo
De S a B
Presión de drenaje de la caja
Presión máxima admisible en la carcasa (orificio Lx):
máximo 7 psi (0,5 bar) superior a la presión de entrada en el puerto S, pero no superior a 29 psi (2 bar) absolutos.
PLaboratorios máx---------------------------29 psi (2 bar)
Tabla de valores (valores teóricos, sin considerar eficiencias y tolerancias; valores redondeados)
| Tamaño | 28 | 45 | 63 | 85 | |||
| Desplazamiento | Vg máx | en3 (cm3) | 1.71(28) | 2.75 (45) | 3.84(63) | 5.19(85) | |
| Velocidad2) | |||||||
| máx. a VG máximo | n0 máx 11) | mín-1 | 3200 | 2900 | 2700 | 2700 | |
| Flujo | |||||||
| en y0 máx | qv0 máx 11) | gpm | 23.8 | 34.6 | 45 | 60.8 | |
| (L/min) | (90) | (131) | (170) | (230) | |||
| Poder | Δp = 3000 psi (210 bar) | ||||||
| en y0 máx | P0 máx 11) | HP(kW) | 42 (31) | 62(46) | 79 (59) | 107 (80) | |
| Par de torsión | Δp = 3000 psi (210 bar) | ||||||
| a las VG máximo | Tmáx | lb-pie (Nm) | 69 (94) | 110 (150) | 155 (210) | 209 (284) | |
| Rigidez torsional | extremo del eje R | c | lb-ft/rad
(Nm/rad) |
10882 | 19480 | 29770 | 51029 |
| (14800) | (26500) | (40500) | (69400) | ||||
| Momento de inercia del grupo rotatorio | JTW | lb-ft/rad
kg/m² |
0.0403 | 0.0474 | 0.0949 | 0.423 | |
| (0,001) | (0,002) | (0,004) | (0,006) | ||||
| Aceleración angular, máx.2) | α | rad/s2 | 6800 | 4900 | 3500 | 2500 | |
| Volumen de casos | V | gal(L) | 0.08 (0,25) | 0.08 (0,3) | 0.13 (0,5) | 0.21 (0,8) | |
| Peso (con control de pres.) | m | libras (kg) | 25.3 (11,5) | 31 (14) | 39.7 (18) | 48.5 (22) | |
1)autocebante con presión absoluta de 15 psi (1 bar) en el puerto de entrada S
2) -Estos valores son válidos para condiciones comprendidas entre las velocidades de accionamiento mínimas requeridas y las máximas admisibles.
Para fuentes externas de excitación (ej. frecuencia de giro de 2 a 8 veces del motor diésel, frecuencia de giro de 2 veces del árbol cardán).
-El límite es válido para una sola bomba.
-Se debe tener en cuenta la capacidad de carga de las piezas de unión.
Precaución: Superar estos límites puede provocar una pérdida de operatividad, una reducción de la vida útil o la destrucción completa de la unidad de pistones axiales.
Los valores permitidos se pueden calcular
Determinación del tamaño de la bomba
| Flujo | qv=(Vg ∙ n ∙ ηv) /231(1000) | gpm (L/min) |
| Par de torsión | M=(Vg ∙ Δp) / 24(20) ∙ π ∙ ηMh | lb-pie (Nm) |
| Poder | P=(2π ∙ M ∙ n)/33000(60000)=(qv ∙ p)/[1714(600) ∙ ηt] | HP(kW) |
Vg=desplazamiento geométrico por revolución en pulgadas3 (cm3)
p = diferencia de presión en psi (bar)
n = velocidad de accionamiento en rpm
ηv = eficiencia volumétrica
ηMh= eficiencia mecánico-hidráulica
ηt= eficiencia global (ηt= ηv*ηMh)
Carga radial y axial permisible en el eje de transmisión
| Tamaño | 28 | 45 | 63 | 85 | ||||
| Fuerza radial, máx. | ![]() |
en X/2 | Fcuántos máximos | libra | 79 | 146 | 225 | 303 |
| (N) | (350) | (650) | (1000) | (1350) | ||||
| Fuerza axial, máx. | ![]() |
Fhacha | libra | 157,4 | 146 | 225 | 303 | |
| (N) | (700) | (650) | (1000) | (1350) | ||||

-3.webp)
-4.webp)
-6.webp)



-2.webp)

-2-1.webp)