شركة ونزهو برانس للمعدات الهيدروليكية المحدودة
محرك مكبس إزاحة متغير ذو تحكم تناهدي كهربائي هيدروليكي A10FM
1.Torque increases with pressure gradient between high and low pressure sides
2.Suitable for walking machinery and industrial applications
3.Allows high output speeds
4.Mature A10 rotating component technology
5.Mechanical and hydraulic connections comply with SAE standards
6.Optional built-in anti-cavitation valve, that is, fan drive unit
وصف تفصيلي
التقييم وطلب عرض الأسعار
This motor series should be selected from the required torque, speed and duty cycle. Confirm displacement, working pressure, case-drain arrangement where applicable, mounting interface and fluid conditions before final selection.
المعلومات التي يجب تضمينها في طلب عرض الأسعار الخاص بك
- Required torque and speed at working pressure
- Preferred displacement or calculated displacement
- Mounting flange, shaft and port orientation
- Duty cycle, fluid, temperature and operating environment
الموارد ذات الصلة
اطلب عرض سعر · مركز التنزيل · تصنيع أصلي / تصنيع تصميمي أصلي
Ordering code for standard program
| A10F | M | / | 52 | - | V | C | ||||||
| 01 | 02 | 03 | 04 | 05 | 06 | 07 | 08 | 09 | 10 | 11 |
وحدة كباس محوري
| 01 | Swashplate design, fixed displacement, nominal pressure 280 bar, maximum pressure 350 bar | A10F |
نمط التشغيل
| 02 | Motor, open and closed circuit | M |
المقاس (NG)
| 03 | Theoretical displacement | 018 | 023 | 028 | 037 | 045 | 058 | 063 |
مسلسل
| 04 | Series 5, Index 2 | 52 |
اتجاه الدوران
| 05 | تمت معاينته على عمود الدوران | مع عقارب الساعة | R1) |
| counter clockwise | L1) | ||
| bidirectional | W |
Seals
| 06 | FKM (Fluoro-rubber) | V |
عمود الدوران
| 018 | 023 | 028 | 037 | 045 | 058 | 063 | |||||
| 07 | Splined shaft to ISO 3019-1 (SAE J744) | ○ | ● | ● | ● | ● | ● | ● | R | ||
| Splined shaft to ISO 3019-1 (SAE J744) | – | ○ | ○ | ● | ● | ● | ● | W | |||
| Tapered with woodruff key and threaded end | ○ | ● | ● | ● | ● | ● | ● | C | |||
شفة التركيب
| 018 | 023 | 028 | 037 | 045 | 058 | 063 | |||
| 08 | SAE 2-hole | ○ | ● | ● | ● | ● | ● | ● | C |
Ports for service lines
| 018 | 023 | 028 | 037 | 045 | 058 | 063 | |||
| 09 | SAE-flange ports A and B on side, same side Mounting bolts metric | - | ● | ● | ● | ● | ● | ● | 10N00 |
| Threaded ports A and B,metric, on side, same side | ○ | ● | ● | ● | ● | ● | ● | 16N00 | |
Ventile
| 018 | 023 | 028 | 037 | 045 | 058 | 063 | |||
| 10 | Without valves | ○ | ● | ● | ● | ● | ● | ● | 0 |
| With integrated flushing valve | - | ● | ● | ● | ● | ● | ● | 7 | |
| With integrated anti cavitation valve | ○ | ● | ● | ● | ● | ● | ● | 2 | |
Speed sensor
| 018 | 023 | 028 | 037 | 045 | 058 | 063 | |||
| 11 | Without speed sensor | ○ | ● | ● | ● | ● | ● | ● | |
| Prepared for speed sensor (for inductive speed sensor ID) | ○ | ● | ● | ● | ● | ○ | ○ | D | |
•=available ○=on request — =not available
1)Only necessary in conjunction with valve configuration "2" (integrated anti cavitation valve)
| A10F | E | / | 52 | - | V | |||||||
| 01 | 02 | 03 | 04 | 05 | 06 | 07 | 08 | 09 | 10 | 11 |
وحدة كباس محوري
| 01 | Swashplate design, fixed displacement, nominal pressure 280 bar, maximum pressure 350 bar | A10F |
نمط التشغيل
| 02 | Motor, open and closed circuit | E |
المقاس (NG)
| 03 | Theoretical displacement | 010 | 011 | 014 | 016 | 018 | 023 | 028 | 037 | 045 | 058 | 063 |
مسلسل
| 04 | Series 5, Index 2 | 52 |
اتجاه الدوران
| 05 | تمت معاينته على عمود الدوران | مع عقارب الساعة | R1) |
| counter clockwise | L1) | ||
| bidirectional | W |
Seals
| 06 | FKM (Fluoro-rubber) | V |
عمود الدوران
| 010 | 011 | 014 | 016 | 018 | 023 | 028 | 037 | 045 | 058 | 063 | |||||
| 07 | Splined shaft to ISO 3019-1 (SAE J744) | ○ | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | R | ||
| Splined shaft to ISO 3019-1 (SAE J744) | – | – | – | – | – | ● | ● | ● | ● | ● | ● | W | |||
| Tapered with woodruff key and threaded end | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | C | |||
شفة التركيب
| 010 | 011 | 014 | 016 | 018 | 023 | 028 | 037 | 045 | 058 | 063 | |||
| 08 | SAE 2-hole | ● | ● | ● | ● | ● | - | - | - | - | - | - | C2) |
| Special 2-hole | - | - | - | - | - | ● | ● | ● | ● | ● | ● | F | |
| Special 8-hole | - | ● | ● | ● | ● | - | - | - | - | - | - | H | |
Ports for service lines
| 010 | 011 | 014 | 016 | 018 | 023 | 028 | 037 | 045 | 058 | 063 | |||
| 09 | SAE-flange ports A and B, on side, same side mounting bolts metric | - | - | - | - | - | ● | ● | ● | ● | ● | ● | 10N00 |
| Threaded ports A and B,metric, on side, same side | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | 16N00 | |
Ventile
| 010 | 011 | 014 | 016 | 018 | 023 | 028 | 037 | 045 | 058 | 063 | |||
| 10 | Without valves | ○ | ● | ○ | ● | ● | ● | ● | ● | ● | ● | ● | 0 |
| With integrated flushing valve | - | - | - | - | - | ● | ● | ● | ● | ● | ● | 7 | |
| With integrated anti cavitation valve | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | 2 | |
Speed sensor
| 010 | 011 | 014 | 016 | 018 | 023 | 028 | 037 | 045 | 058 | 063 | |||
| 11 | Without speed sensor | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
| Prepared for speed sensor (for inductive speed sensor ID) | – | – | – | – | ○ | ● | ● | ● | ● | ○ | ○ | D | |
•=available ○=on request — =not available
1)Only necessary in conjunction with valve configuration "2" (integrated anti cavitation valve)
2)R-shaft with C-flange on sizes 10 to 18 in preparation
البيانات الفنية
Fluids
Prior to project design, please see our technical data sheets RE 90220 (mineral oil) and RE 90221 (environmentally acceptable fluids) for detailed information on fluids and operating conditions.
For operation on environmentally acceptable fluids please consult us (when ordering, please state in clear text the fluid to be used).
Operating viscosity range
To achieve optimum values for efficiency and service life we recommend an operation viscosity (at operating temperature)within the range,
νopt = opt. operating viscosity 16...36 mm2/s
referred to the tank temperature (open circuit).
Limit of viscosity range
For critical operation conditions the following values apply:
νmin=5 mm2/s (closed circuit)
10 mm2/s (open circuit)
for short periods (t ≤ 1 min)
at a max. perm. temperature of 115 ℃.
Please note that the max. leakage fluid temperature of 115 ℃ is also not exceeded in certain areas (for instance bearing area).The fluid temperature in the bearing area is approx.5 K higher than the average leakage fluid temperature
νالحد الأقصى=1600 mm2/s
for short periods (t≤1 min)
on cold start
(tmin =p≤ 30 bar, n ≤ 1000 min-1,-25 °C).
At temperatures between -40℃ and -25℃ special measures are required, please consult us for further information.For detailed information on operation with low temperatures see data sheet RE 90300-03-B.
Selection diagram

Notes on the selection of the hydraulic fluid
In order to select the correct fluid, it is necessary to know the operating temperature in the tank (open circuit) in relation to the ambient temperature.
The fluid should be selected so that within the operating temperature range, the viscosity lies within the optimum range (νopt),see shaded section of the selection diagram. We recommend to select the higher viscosity grade in each case.
Example: at an ambient temperature of X℃ the operating temperature in the tank is 60℃. In the optimum viscosity range(νopt; shaded area) this corresponds to viscosity grades VG 46 resp. VG 68; VG 68 should be selected.
Important:
The leakage oil (case drain oil) temperature is influenced by pressure and input speed and is always higher than the tank temperature. However, at no point of the component may the temperature exceed 115℃.
If it is not possible to comply with the above conditions because of extreme operating parameters please consult us.
Filtration of the hydraulic fluid
Filtration improves the cleanliness level of the hydraulic fluid,which, in turn, increases the service life of the axial piston unit.
To ensure the functional reliability of the axial piston unit, a gravimetric evaluation is necessary for the hydraulic fluid to determine the amount of contamination by solid matter and to determine the cleanliness level according to ISO 4406.A cleanliness level of at least 20/18/15 to ISO 4406 is to be maintained.
If above requirements cannot be maintained please consult us.
Operating pressure range
Pressure at service line port (pressure port) A or B
| الضغط الاسمي Pnom | 280 bar absolute |
| Maximum pressure Pالحد الأقصى | 350 bar absolute |
| Single operating period | 2,5 ms |
| Total operating period | 300 h |
| Minimum pressure (high pressure side) | 10 bar2) |
| Rate of pressure change RA max | 16000 bar/s |

ضغط المخرج
| at nالحد الأقصى | |
| Minimum pressure at low pressure side Pabs max | 18 bar |
ضغط تصريف العلبة
Maximum permissible case drain pressure
(at port L, L1):
| Pmax abs motor operation in open circuit | 4 bar abs |
| Pmax abs motor operation in closed circuit | 4 bar abs |
| Pmax abs pump/motor operation in open circuit | 2 bar abs |
Direction of flow
| viewed on drive shaft | |||||
| clockwise rotation | counter clockwise rotation | ||||
| A to B | B to A | ||||
Definitions
الضغط الاسمي Pnom
The nominal pressure corresponds to the maximum design
pressure.
Maximum pressure Pالحد الأقصى
The maximum pressure corresponds to the maximum operating pressure within the single operating period. The sum of the single operating periods must not exceed the total operating period.
Minimum pressure (high-pressure side)
Minimum pressure at the high pressure side (A or B) which is required in order to prevent damage to the axial piston unit.
Rate of pressure change RA
Maximum permissible rate of pressure rise and pressure reduction during a pressure change, over the entire pressure range.

Total operating period =t1 + t2 +... + tn
1)Other values on request
2)Lower pressures time dependent, please consult us.
Table of values (theoretical values, without efficiency and tolerances: value rounded)
| حجم | غير مقبول | 010 | 011 | 014 | 016 | 018 | 023 | ||
| إزاحة | Vجي ماكس | سم3 | 10.6 | 11.5 | 14.1 | 16.1 | 18 | 23.5 | |
| Speed1) | 5000 | 4200 | 4200 | 4200 | 4200 | 4900 | |||
| at Vجي ماكس | nnom | دورة في الدقيقة | |||||||
| Input flow | 53 | 48 | 59 | 68 | 76 | 115 | |||
| at nnom | qv max | لتر/دقيقة | |||||||
| Power | 24.7 | 22.5 | 27.6 | 31.6 | 35.3 | 53.6 | |||
| at nnom, Δp= 280 bar | P الحد الأقصى | كيلوواط | |||||||
| Actual starting torque | 37.5 | 30 | 45 | 53 | 67.5 | 75 | |||
| at n= 0 rpm, Δp = 280 bar | لا شيء جديد | ||||||||
| Torque | 47 | 51 | 63 | 72 | 80 | 105 | |||
| at Vجي ماكس | Δp = 280 bar | Tالحد الأقصى | لا شيء جديد | ||||||
| Torsional stiffness | R | c | Nm/rad | - | - | - | - | 14835 | 28478 |
| عمود الدوران | W | c | Nm/rad | - | - | - | - | - | - |
| C | c | Nm/rad | 15084 | 18662 | 18662 | 18662 | 18662 | 30017 | |
| Moment of inertia rotary group | JTW | kgm2 | 0.0006 | 0.00093 | 0.00093 | 0.00093 | 0.00093 | 0.0017 | |
| Maximum angular acceleration | α | rad/s2 | 8000 | 6800 | 6800 | 6800 | 6800 | 5500 | |
| Case volume | V | L | 0.1 | 0.15 | 0.15 | 0.15 | 0.15 | 0.6 | |
| Weight approx. | m | kg | 5 | 6.5 | 6.5 | 6.5 | 6.5 | 12 | |
| حجم | غير مقبول | 028 | 037 | 045 | 058 | 063 | ||
| إزاحة | Vجي ماكس | سم3 | 28.5 | 11.5 | 14.1 | 16.1 | 18 | |
| Speed1) | ||||||||
| at Vجي ماكس | nnom | دورة في الدقيقة | 4700 | 4200 | 4000 | 3600 | 3400 | |
| Input flow | 134 | 154 | 178 | 209 | 215 | |||
| at nnom | qv max | لتر/دقيقة | ||||||
| Power | 62.5 | 71.8 | 83.1 | 97.4 | 100.1 | |||
| at nnom, Δp= 280 bar | P الحد الأقصى | كيلوواط | ||||||
| Actual starting torque | 105 | 125 | 170 | 205 | 230 | |||
| at n= 0 min-1, Δp = 280 bar | لا شيء جديد | |||||||
| Torque | 127 | 163 | 198 | 258 | 281 | |||
| at Vجي ماكس | Δp = 280 bar | Tالحد الأقصى | لا شيء جديد | |||||
| Torsional stiffness | R | c | Nm/rad | 28478 | 46859 | 46859 | 80590 | 80590 |
| عمود الدوران | W | c | Nm/rad | - | 38489 | 38489 | 60907 | 60907 |
| C | c | Nm/rad | 30017 | 46546 | 46546 | 87667 | 87667 | |
| Moment of inertia rotary group | JTW | kgm2 | 0.0017 | 0.0033 | 0.0033 | 0.0056 | 0.0056 | |
| Maximum angular acceleration | α | rad/s2 | 5500 | 4000 | 4000 | 3300 | 3300 | |
| Case volume | V | L | 0.6 | 0.7 | 0.7 | 0.8 | 0.8 | |
| Weight approx. | m | kg | 12 | 17 | 17 | 22 | 22 | |
1)for maximum speed an outlet pressure (in low pressure side) of 18 bar is required
Note
Operation above the maximum values or below the minimum values may result in a loss of function, a reduced service life or in the destruction of the axial piston unit We recommend testing the loads by means of experiment or calculation/ simulation and comparison with the permissible values.
Permissible motor speed in relation to outlet pressure

Determination of motor size (NG)
| Input flow | qv=(Vg∙n)/(1000∙ηv) | [L/min] | Vg=Displacement per revolution in cm3 Δp=Differential pressure in bar n=speed in rpm ηv=Volumetric efficiency ηمم=Mechanical-hydraulic efficiency ηt=Overall efficiency (ηt = ηv ∙ηمم) TK=Torque constant |
| Torque | T=(1,59∙Vg∙ Δp∙ηمم)/100 | [Nm] | |
| or | T=Tk∙ Δp∙ηمم | ||
| Power | P=(2π∙T∙n)/60000=(qv∙Δp∙ηt)/600 | [kW] | |
| Output speed | n=(qv∙1000∙ηv)/Vg | [rpm] | |
Permissible radial and axial forces on the drive shaft
| Max. radial force at X/2 | Drive shaft R; W | Drive shaft C | Fq max | N | 250 | 350 | 350 | 350 | 350 | 1200 |
![]() |
![]() |
|||||||||
| Maximum axial force | ![]() |
± Fax max | N | 400 | 700 | 700 | 700 | 700 | 1000 |
| حجم | غير مقبول | 28 | 37 | 45 | 58 | 63 | |||
| Max. radial force at X/2 | Drive shaft R; W | Drive shaft C | Fq max | N | 1200 | 1500 | 1500 | 1700 | 1700 |
![]() |
![]() |
||||||||
| Maximum axial force | ![]() |
± Fax max | N | 1000 | 1500 | 1500 | 2000 | 2000 | |