Wenzhou Prance Hydraulic Equipment Co., Ltd.
A7VO Bent Axis Variable Displacement Pump
The A7VO variable pump uses a bent-axis rotary group for open-circuit drives. Changing its displacement changes delivered flow at a given drive speed. The selected controller must match the pressure, power or flow behavior required by the machine.
- Variable bent-axis rotary group
- Open-circuit hydrostatic drives
- Mobile and stationary applications
- Control devices selected by order code
PRANCE HYDRAULIC · PRODUCT SERIES
Axial piston; bent axis, variable displacement · Open circuit
The A7VO variable pump uses a bent-axis rotary group for open-circuit drives. Changing its displacement changes delivered flow at a given drive speed. The selected controller must match the pressure, power or flow behavior required by the machine.
Model

Confirm the complete model and approved specification with Prance Hydraulic. Product-series references alone do not establish interchangeability.
Configuration review · Technical documentation · Product selection
Produktdetails
- Variable bent-axis rotary group
- Open-circuit hydrostatic drives
- Mobile and stationary applications
- Control devices selected by order code
CATEGORIES: Kolbenpumpe, Verstellpumpe
A7VO Features & Application
Variable bent-axis rotary group
Specify the displacement range or switching arrangement and verify performance at each required setting.
Open-circuit hydrostatic drives
Review normal running, startup and reversal where applicable. The pressure and flow requirements can differ between operating states.
Mobile and stationary applications
Compare the required flow at the actual drive speed and pressure. Check the selected variant rather than combining maxima from different rows.
Control devices selected by order code
Match the complete control option and its command requirements to the existing controller. Similar housings can use different control arrangements.
A7VO Specifications
| Series / model | A7VO |
|---|---|
| Product type | A7VO Bent Axis Variable Displacement Pump |
| Design | Axial piston; bent axis, variable displacement |
| Circuit / selection | Open circuit |
| Published nominal sizes | 28, 55, 80, 107 and 160 |
| Listed geometric displacement | 28.1, 54.8, 80, 107 and 160 cm³/rev |
A7VO Selection & Configuration
The A7VO variable pump uses a bent-axis rotary group for open-circuit drives. Changing its displacement changes delivered flow at a given drive speed. The selected controller must match the pressure, power or flow behavior required by the machine.
Specify the operating points across the work cycle and compare them with the control characteristic. Verify inlet conditions at the highest flow demand and check the shaft, mounting flange and drain connections against the A7VO drawing.

cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits.
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits.
Hydraulic pumps · Hydraulic motors · Hydraulic valves
Send the MS nameplate, operating requirements and installation drawing for a configuration review before quoting.
- Model review — send the full model code or an existing nameplate photograph.
- Interface matching — confirm shaft, mounting flange, rotation and ports.
- Operating conditions — provide flow, pressure, speed, fluid and duty cycle.
- Documentation — request the relevant product data and drawings for your review.

A7VO Buying Guide
Use this sequence to prepare the A7VO configuration for review and quotation.
- Define required flow at the actual drive speed and continuous pressure.
- Identify peak pressure, duration and the work cycle.
- Confirm the selected displacement control and any auxiliary-drive requirement.
- Match rotation viewed from the shaft end, shaft, flange and ports.
- Review inlet conditions, drain routing and the installation envelope.
- Confirm fluid, viscosity, temperature, filtration and seals.
- Approve the complete model, control, drawing, quantity and delivery terms.

Selection, Documentation & Project Support

Selection Support
Learn more →Share your hydraulic circuit, operating point and installation requirements for a configuration discussion.
Flow · Pressure · Speed · Interfaces

Technical Resources
Learn more →Review product documentation, model codes and technical data before finalizing the specification.
Datasheets · Model codes · Drawings

Project Inquiries
Learn more →Send your required model, quantity, application and project requirements to discuss your inquiry.
Product inquiries · Configuration review
Configuration, Quantity & Delivery
Confirm the complete MS code, approved drawing and operating limits. Availability, quantity, documentation and delivery date are confirmed in the quotation.
Discuss Your A7VO Application
Send the full model code, operating duty, installation details and quantity.
Request a A7VO QuotationA7VO Questions Before Ordering
What type of product is the A7VO?
A7VO Bent Axis Variable Displacement Pump. Design: Axial piston; bent axis, variable displacement. Open circuit. Confirm the complete order code for the offered version.
Can a similar pump replace the A7VO?
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits.
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits
Define required flow at the actual drive speed and continuous pressure. Identify peak pressure, duration and the work cycle. Attach the nameplate, complete order code, installation drawing and required quantity.
A7VO Technical Data & Documents
View A7VO catalog data and operating conditions
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits.
Technische Daten
| Größe | NG | 28 | 55 | 80 | 107 | 160 | ||
| Geometrisches Fördervolumen pro Umdrehung | VGroßmutterx | cm3 | 28.1 | 54.8 | 80 | 107 | 160 | |
| Maximale Drehzahl 1) | Bei VG-Max | nnom | U/min | 3150 | 2500 | 2240 | 2150 | 1900 |
| Bei Vg<0,74 x Vg Max | nmax1 | U/min | 4250 | 3400 | 3000 | 2900 | 2560 | |
| Maximale Drehzahl 2) | nmax2 | U/min | 4750 | 3750 | 3350 | 3200 | 2850 | |
| Verdrehsteifigkeit | Vg Max zu V g/2 | cmin. | kNm/rad | 5 | 10 | 16 | 21 | 36 |
| Vg/2 auf 0 (interpoliert) | cMax | kNm/rad | 16 | 32 | 49 | 67 | 104 | |
| Trägheitsmoment der Dreheinheit | JTW | kgm2 | 0.0042 | 0.0042 | 0.0080 | 0.0127 | 0.0253 | |
| Maximale Winkelbeschleunigung | α | rad/s2 | 35900 | 31600 | 24200 | 19200 | 15300 | |
| Fallzahl | V | l | 0.5 | 0.75 | 1.2 | 1.5 | 2.4 | |
| Gewicht (ca.) | m | kg | 17 | 25 | 40 | 49 | 71 | |
Höchstzulässige Geschwindigkeit (Tempolimit)
Bestimmung der Betriebskennlinien
Schlüssel
Vg = Hubvolumen pro Umdrehung [cm3] Δp = Differential pressure [bar] n = Rotational speed [rpm] ηv = Volumetric efficiency ηmh = Hydraulic-mechanical efficiency ηt = Gesamtwirkungsgrad (ηt= ηv*ηmh)Notizen
▶Theore tical values, without efficiency and tolerances;values rounded ▶Operation above the maximum values or below the minimum values may result in a loss of function, a reduced service life or in the destruction of the axial piston unit. Other permissible limit values, such as speed variation, reduced angular acceleration as a function of the frequency and the permissible angular acceleration at start (lower than the maximum angular acceleration) can be found in data sheet 90261. 1) The values are valid: – At absolute pressure PABS = 1 bar at suction port S – For the optimal viscosity range of ventscheiden = 36 bis 16 mm2/s -For hydraulic fluid based on mineral oils. 2) Maximum rotational speed (speed limit) for increased inlet pressure PABS an den Sauganschlüssen S und Vg < Vg Max , siehe Abbildung.Related Selection Resources
Request a A7VO Quotation
Tell us your required configuration, quantity and application.
Bestellcode
| 01 | 02 | 03 | 04 | 05 | 06 | 07 | 08 | 09 | 10 | 11 | 12 | 13 | ||
| A7V | ○ | / | 63 | - | V | B | 01 |
Axialkolbeneinheit
| 01 | Schrägaxsenbauart, verstellbar, Nenndruck 350 bar, Maximaldruck 400 bar | A7V |
Betriebsart
| 02 | Pumpe, offener Kreisklauf | ○ |
Größe (NG)
| 03 | Geometrisches Verdrängungsvolumen V2 (cm³), siehe "Technische Daten" auf Seite 7 | 28 | 55 | 80 | 107 | 160 |
| Für die Größen 250, 355 und 500 siehe Datenblatt 92203 | ||||||
Steuergerät
| 28 | 55 | 80 | 107 | 160 | |||||
| 04 | Leistungsregler ohne Leistungsumschaltung | ● | ● | ● | ● | ● | LR | ||
| mit Abschaltvorrichtung | ● | ● | ● | ● | ● | LRD | |||
| mit Hubbegrenzung | Negativkontrolle | Δp = 25 bar | - | ● | ● | ● | ● | LRH1 | |
| mit Druckabschneidung und Hubbegrenzung | Negativkontrolle | Δp = 25 bar | - | ● | ● | ● | ● | LRDH1 | |
| mit Druckabschaltung und Load Sensing | - | ● | ● | ● | ● | LRDS | |||
| Leistungsregler mit hydraulisch proportionaler Leistungsüberssteuerung
(nur für Rechtsdrehung und mit Anschlussplatte 02 verfügbar) |
|||||||||
| mit Lasterfassung | - | ● | ● | - | - | LA1S | |||
| mit Load-Sensing und hydraulisch proportionaler LS-Übersteuerung | - | ● | ● | - | - | LA1S5 | |||
| Druckregler | ● | ● | ● | ● | ● | DR | |||
| fernbedient | ● | ● | ● | ● | ● | DRG | |||
| mit Lasterfassung | - | ● | ● | ● | ● | DRS | |||
| Proportionalhydraulik | Positivkontrolle | Δp = 10 bar | ● | ● | ● | ● | ● | HD1 | |
| mit Abschaltautomatik, ferngesteuert | Positivkontrolle | Δp = 10 bar | ● | ● | ● | ● | ● | HD1G | |
| Proportionalsteuerung elektrisch | Positivkontrolle | U=24V | ● | ● | ● | ● | ● | EP2 | |
Serie
| 05 | Serie 6, Index 3 | 63 |
Drehrichtung
| 28 bis 160 | ||||
| 06 | Auf Antriebswelle betrachtet | im Uhrzeigersinn | ● | R |
| gegen den Uhrzeigersinn | ● | L | ||
Dichtungsmaterial
| 07 | FKM (Fluorelastomer) | V |
Antriebswelle
| 28 bis 160 | |||
| 08 | Passverzahnte Welle DIN 5480 | ● | Z |
| Passfederwelle nach DIN 6885 | ● | P | |
Montageflansch
| 09 | ISO 3019-2; 4-Loch | B |
Anschlussplatte für Arbeitsleitungen
| 10 | SAE-Flanschanschlüsse A und S hinten (metrisches Befestigungsgewinde) | 01 |
| SAE-Flanschanschlüsse A und S seitlich (nur für Leistungskontroller LA1S und LA1S5 verfügbar, metrisches Befestigungsgewinde) | 02 |
• = verfügbar - = nicht verfügbar
= bevorzugtes Programm
| 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | ||
| A7V | ○ | / | 63 | - | V | B | 1 |
Magnetstecker1)
| 11 | Ohne Stecker (ohne Magnetventil, nur mit hydraulischer Steuerung; ohne Code) | |
| DEUTSCH Flachsteckergehäuse, 2-polig – ohne Löschdiode | P |
Standard- / Sonderversion
| 12 | Standardversion (ohne Code) | |
| Sonderversion | -S |
• = verfügbar - = nicht verfügbar
= bevorzugtes Programm
Notizen
Konservierung
- Bis zu 12 Monate standardmäßig
-Bis zu 24 Monate langfristig
(bei der Bestellung im Klartext angeben)
Technische Daten
| Größe | NG | 28 | 55 | 80 | 107 | 160 | ||
| Geometrisches Fördervolumen pro Umdrehung | VGroßmutterx | cm3 | 28.1 | 54.8 | 80 | 107 | 160 | |
| Maximale Drehzahl 1) | Bei VG-Max | nnom | U/min | 3150 | 2500 | 2240 | 2150 | 1900 |
| Bei Vg<0,74 x Vg Max | nmax1 | U/min | 4250 | 3400 | 3000 | 2900 | 2560 | |
| Maximale Drehzahl 2) | nmax2 | U/min | 4750 | 3750 | 3350 | 3200 | 2850 | |
| Fluss | Bei VG-Max und nnom | qv | l/min | 89 | 137 | 179 | 230 | 304 |
| Macht | Bei VG-Max , nnom und Δp = 350 bar | P | kW | 52 | 80 | 105 | 134 | 177 |
| Drehmoment | Bei VG-Max und Δp = 350 bar | T | Machs gut | 156 | 305 | 446 | 596 | 891 |
| Verdrehsteifigkeit | Vg Max zu V g/2 | cmin. | kNm/rad | 5 | 10 | 16 | 21 | 36 |
| Vg/2 auf 0 (interpoliert) | cMax | kNm/rad | 16 | 32 | 49 | 67 | 104 | |
| Trägheitsmoment der Dreheinheit | JTW | kgm2 | 0.0042 | 0.0042 | 0.0080 | 0.0127 | 0.0253 | |
| Maximale Winkelbeschleunigung | α | rad/s2 | 35900 | 31600 | 24200 | 19200 | 15300 | |
| Fallzahl | V | l | 0.5 | 0.75 | 1.2 | 1.5 | 2.4 | |
| Gewicht (ca.) | m | kg | 17 | 25 | 40 | 49 | 71 | |
Höchstzulässige Geschwindigkeit (Tempolimit)

Bestimmung der Betriebskennlinien
| Fluss | qv=(Vg ∙ n ∙ ηv) / 1000 | l/min |
| Drehmoment | T=(Vg ∙ Δp) /(20 ∙ π ∙ ηmh) | Machs gut |
| Macht | P=(2π ∙ T ∙ n)/60000=(qv ∙ Δp)/(600 ∙ ηt) | kW |
Schlüssel
Vg = Hubvolumen pro Umdrehung [cm3]
Δp = Differenzdruck [bar]
n = Drehzahl [U/min]
ηv = Volumetrischer Wirkungsgrad
ηmh = Hydraulisch-mechanischer Wirkungsgrad
ηt = Gesamtwirkungsgrad (ηt= ηv*ηmh)
Notizen
▶ Theoretische Werte, ohne Wirkungsgrad und Toleranzen; Werte gerundet
▶Ein Betrieb oberhalb der Maximalwerte oder unterhalb der Minimalwerte kann zum Funktionsverlust, zu einer verkürzten Lebensdauer oder zur Zerstörung der Axialkolbeneinheit führen. Weitere zulässige Grenzwerte, wie Drehzahländerung, reduzierte Winkelbeschleunigung in Abhängigkeit von der Frequenz und die zulässige Winkelbeschleunigung beim Start (kleiner als die maximale Winkelbeschleunigung), sind dem Datenblatt 90261 zu entnehmen.
1) Die Werte sind gültig:
- Bei absolutem Druck PABS = 1 bar am Sauganschluss S
- Für den optimalen Viskositätsbereich von ventscheiden = 36 bis 16 mm2/s
-Für Hydraulikflüssigkeit auf Mineralölbasis.
2) Maximale Drehzahl (Drehzahlgrenze) für erhöhten Einlassdruck PABS an den Sauganschlüssen S und Vg < Vg Max , siehe Abbildung.






-2.webp)