A7VO Bent Axis Variable Displacement Pump

The A7VO variable pump uses a bent-axis rotary group for open-circuit drives. Changing its displacement changes delivered flow at a given drive speed. The selected controller must match the pressure, power or flow behavior required by the machine.

  • Variable bent-axis rotary group
  • Open-circuit hydrostatic drives
  • Mobile and stationary applications
  • Control devices selected by order code
HOME › Hydraulikpumpen › A7VO

PRANCE HYDRAULIC · PRODUCT SERIES

A7VO Bent Axis Variable Displacement Pump

Axial piston; bent axis, variable displacement · Open circuit

The A7VO variable pump uses a bent-axis rotary group for open-circuit drives. Changing its displacement changes delivered flow at a given drive speed. The selected controller must match the pressure, power or flow behavior required by the machine.

Model

✓A7VO original product photograph
A7VOAxial piston; bent axis, variable displacement
Request a QuotationTechnische Daten & Datenblatt anzeigen

Confirm the complete model and approved specification with Prance Hydraulic. Product-series references alone do not establish interchangeability.

Configuration review · Technical documentation · Product selection

Produktdetails

  • Variable bent-axis rotary group
  • Open-circuit hydrostatic drives
  • Mobile and stationary applications
  • Control devices selected by order code

CATEGORIES: Kolbenpumpe, Verstellpumpe

A7VO Features & Application

Variable bent-axis rotary group

Specify the displacement range or switching arrangement and verify performance at each required setting.

Open-circuit hydrostatic drives

Review normal running, startup and reversal where applicable. The pressure and flow requirements can differ between operating states.

Mobile and stationary applications

Compare the required flow at the actual drive speed and pressure. Check the selected variant rather than combining maxima from different rows.

Control devices selected by order code

Match the complete control option and its command requirements to the existing controller. Similar housings can use different control arrangements.

A7VO Specifications

Series / modelA7VO
Product typeA7VO Bent Axis Variable Displacement Pump
DesignAxial piston; bent axis, variable displacement
Circuit / selectionOpen circuit
Published nominal sizes28, 55, 80, 107 and 160
Listed geometric displacement28.1, 54.8, 80, 107 and 160 cm³/rev

A7VO Selection & Configuration

The A7VO variable pump uses a bent-axis rotary group for open-circuit drives. Changing its displacement changes delivered flow at a given drive speed. The selected controller must match the pressure, power or flow behavior required by the machine.

Specify the operating points across the work cycle and compare them with the control characteristic. Verify inlet conditions at the highest flow demand and check the shaft, mounting flange and drain connections against the A7VO drawing.

cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits

cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits.
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits.

Hydraulic pumps · Hydraulic motors · Hydraulic valves

Send the MS nameplate, operating requirements and installation drawing for a configuration review before quoting.

  • Model review — send the full model code or an existing nameplate photograph.
  • Interface matching — confirm shaft, mounting flange, rotation and ports.
  • Operating conditions — provide flow, pressure, speed, fluid and duty cycle.
  • Documentation — request the relevant product data and drawings for your review.
Prance workshop with a row of production equipment

A7VO Buying Guide

Use this sequence to prepare the A7VO configuration for review and quotation.

  1. Define required flow at the actual drive speed and continuous pressure.
  2. Identify peak pressure, duration and the work cycle.
  3. Confirm the selected displacement control and any auxiliary-drive requirement.
  4. Match rotation viewed from the shaft end, shaft, flange and ports.
  5. Review inlet conditions, drain routing and the installation envelope.
  6. Confirm fluid, viscosity, temperature, filtration and seals.
  7. Approve the complete model, control, drawing, quantity and delivery terms.
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits

Selection, Documentation & Project Support

Prance technical team image from its company website

Selection Support

Learn more →

Share your hydraulic circuit, operating point and installation requirements for a configuration discussion.


Flow · Pressure · Speed · Interfaces
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits

Technical Resources

Learn more →

Review product documentation, model codes and technical data before finalizing the specification.


Datasheets · Model codes · Drawings
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits

Project Inquiries

Learn more →

Send your required model, quantity, application and project requirements to discuss your inquiry.


Product inquiries · Configuration review

Configuration, Quantity & Delivery

Confirm the complete MS code, approved drawing and operating limits. Availability, quantity, documentation and delivery date are confirmed in the quotation.

Discuss Your A7VO Application

Send the full model code, operating duty, installation details and quantity.

Request a A7VO Quotation

A7VO Questions Before Ordering

What type of product is the A7VO?

A7VO Bent Axis Variable Displacement Pump. Design: Axial piston; bent axis, variable displacement. Open circuit. Confirm the complete order code for the offered version.

Can a similar pump replace the A7VO?

cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits.

cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits

Define required flow at the actual drive speed and continuous pressure. Identify peak pressure, duration and the work cycle. Attach the nameplate, complete order code, installation drawing and required quantity.

A7VO Technical Data & Documents

View A7VO catalog data and operating conditions

cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits.

Technische Daten

Größe NG 28 55 80 107 160
Geometrisches Fördervolumen pro Umdrehung VGroßmutterx cm3 28.1 54.8 80 107 160
Maximale Drehzahl 1) Bei VG-Max nnom U/min 3150 2500 2240 2150 1900
Bei Vg<0,74 x Vg Max nmax1 U/min 4250 3400 3000 2900 2560
Maximale Drehzahl 2) nmax2 U/min 4750 3750 3350 3200 2850
Verdrehsteifigkeit Vg Max zu V g/2 cmin. kNm/rad 5 10 16 21 36
Vg/2 auf 0 (interpoliert) cMax kNm/rad 16 32 49 67 104
Trägheitsmoment der Dreheinheit JTW kgm2 0.0042 0.0042 0.0080 0.0127 0.0253
Maximale Winkelbeschleunigung α rad/s2 35900 31600 24200 19200 15300
Fallzahl V l 0.5 0.75 1.2 1.5 2.4
Gewicht (ca.) m kg 17 25 40 49 71

Höchstzulässige Geschwindigkeit (Tempolimit)

A11VO technical reference from the existing product documentation

Bestimmung der Betriebskennlinien

Schlüssel

Vg = Hubvolumen pro Umdrehung [cm3] Δp = Differential pressure [bar] n = Rotational speed [rpm] ηv  = Volumetric efficiency ηmh = Hydraulic-mechanical efficiency ηt  = Gesamtwirkungsgrad (ηt= ηv*ηmh)

Notizen

▶Theore tical values, without efficiency and tolerances;values rounded ▶Operation above the maximum values or below the minimum values may result in a loss of function, a reduced service life or in the destruction of the axial piston unit. Other permissible limit values, such as speed variation, reduced angular acceleration as a function of the frequency and the permissible angular acceleration at start (lower than the maximum angular acceleration) can be found in data sheet 90261. 1) The values are valid: – At absolute pressure PABS = 1 bar at suction port S – For the optimal viscosity range of ventscheiden = 36 bis 16 mm2/s -For hydraulic fluid based on mineral oils. 2) Maximum rotational speed (speed limit) for increased inlet pressure PABS an den Sauganschlüssen S und Vg < Vg Max , siehe Abbildung.

Request a A7VO Quotation

Tell us your required configuration, quantity and application.

Kontaktformular-Demo
A7VO original product photograph

Bestellcode

01 02 03 04 05 06 07 08 09 10 11 12 13
A7V ○ / 63 - V B 01

Axialkolbeneinheit

01 Schrägaxsenbauart, verstellbar, Nenndruck 350 bar, Maximaldruck 400 bar A7V

Betriebsart

02 Pumpe, offener Kreisklauf ○

Größe (NG)

03 Geometrisches Verdrängungsvolumen V2 (cm³), siehe "Technische Daten" auf Seite 7 28 55 80 107 160
Für die Größen 250, 355 und 500 siehe Datenblatt 92203

Steuergerät

28 55 80 107 160
04 Leistungsregler ohne Leistungsumschaltung ● ● ● ● ● LR
mit Abschaltvorrichtung ● ● ● ● ● LRD
mit Hubbegrenzung Negativkontrolle Δp = 25 bar - ● ● ● ● LRH1
mit Druckabschneidung und Hubbegrenzung Negativkontrolle Δp = 25 bar - ● ● ● ● LRDH1
mit Druckabschaltung und Load Sensing - ● ● ● ● LRDS
Leistungsregler mit hydraulisch proportionaler Leistungsüberssteuerung

(nur für Rechtsdrehung und mit Anschlussplatte 02 verfügbar)

mit Lasterfassung - ● ● - - LA1S
mit Load-Sensing und hydraulisch proportionaler LS-Übersteuerung - ● ● - - LA1S5
Druckregler ● ● ● ● ● DR
fernbedient ● ● ● ● ● DRG
mit Lasterfassung - ● ● ● ● DRS
Proportionalhydraulik Positivkontrolle Δp = 10 bar ● ● ● ● ● HD1
mit Abschaltautomatik, ferngesteuert Positivkontrolle Δp = 10 bar ● ● ● ● ● HD1G
Proportionalsteuerung elektrisch Positivkontrolle U=24V ● ● ● ● ● EP2

Serie

05 Serie 6, Index 3 63

Drehrichtung

28 bis 160
06 Auf Antriebswelle betrachtet im Uhrzeigersinn ● R
gegen den Uhrzeigersinn ● L

Dichtungsmaterial

07 FKM (Fluorelastomer) V

Antriebswelle

28 bis 160
08 Passverzahnte Welle DIN 5480 ● Z
Passfederwelle nach DIN 6885 ● P

Montageflansch

09 ISO 3019-2; 4-Loch B

Anschlussplatte für Arbeitsleitungen

10 SAE-Flanschanschlüsse A und S hinten (metrisches Befestigungsgewinde) 01
SAE-Flanschanschlüsse A und S seitlich (nur für Leistungskontroller LA1S und LA1S5 verfügbar, metrisches Befestigungsgewinde) 02

• = verfügbar - = nicht verfügbar     = bevorzugtes Programm

1 2 3 4 5 6 7 8 9 10 11 12 13
A7V ○ / 63 - V B 1

Magnetstecker1)

11 Ohne Stecker (ohne Magnetventil, nur mit hydraulischer Steuerung; ohne Code)
DEUTSCH Flachsteckergehäuse, 2-polig – ohne Löschdiode P

Standard- / Sonderversion

12 Standardversion (ohne Code)
Sonderversion -S

• = verfügbar - = nicht verfügbar     = bevorzugtes Programm

Notizen

Konservierung

- Bis zu 12 Monate standardmäßig

-Bis zu 24 Monate langfristig

(bei der Bestellung im Klartext angeben)

Technische Daten

Größe NG 28 55 80 107 160
Geometrisches Fördervolumen pro Umdrehung VGroßmutterx cm3 28.1 54.8 80 107 160
Maximale Drehzahl 1) Bei VG-Max nnom U/min 3150 2500 2240 2150 1900
Bei Vg<0,74 x Vg Max nmax1 U/min 4250 3400 3000 2900 2560
Maximale Drehzahl 2) nmax2 U/min 4750 3750 3350 3200 2850
Fluss Bei VG-Max und nnom qv l/min 89 137 179 230 304
Macht Bei VG-Max , nnom und Δp = 350 bar P kW 52 80 105 134 177
Drehmoment Bei VG-Max und Δp = 350 bar T Machs gut 156 305 446 596 891
Verdrehsteifigkeit Vg Max zu V g/2 cmin. kNm/rad 5 10 16 21 36
Vg/2 auf 0 (interpoliert) cMax kNm/rad 16 32 49 67 104
Trägheitsmoment der Dreheinheit JTW kgm2 0.0042 0.0042 0.0080 0.0127 0.0253
Maximale Winkelbeschleunigung α rad/s2 35900 31600 24200 19200 15300
Fallzahl V l 0.5 0.75 1.2 1.5 2.4
Gewicht (ca.) m kg 17 25 40 49 71

Höchstzulässige Geschwindigkeit (Tempolimit)

Bestimmung der Betriebskennlinien

Fluss qv=(Vg ∙ n ∙ ηv) / 1000 l/min
Drehmoment T=(Vg ∙ Δp) /(20 ∙ π ∙ ηmh) Machs gut
Macht P=(2π ∙ T ∙ n)/60000=(qv ∙ Δp)/(600 ∙ ηt)  kW

Schlüssel

Vg = Hubvolumen pro Umdrehung [cm3]

Δp = Differenzdruck [bar]

n = Drehzahl [U/min]

ηv  = Volumetrischer Wirkungsgrad

ηmh = Hydraulisch-mechanischer Wirkungsgrad

ηt  = Gesamtwirkungsgrad (ηt= ηv*ηmh)

Notizen

▶ Theoretische Werte, ohne Wirkungsgrad und Toleranzen; Werte gerundet

▶Ein Betrieb oberhalb der Maximalwerte oder unterhalb der Minimalwerte kann zum Funktionsverlust, zu einer verkürzten Lebensdauer oder zur Zerstörung der Axialkolbeneinheit führen. Weitere zulässige Grenzwerte, wie Drehzahländerung, reduzierte Winkelbeschleunigung in Abhängigkeit von der Frequenz und die zulässige Winkelbeschleunigung beim Start (kleiner als die maximale Winkelbeschleunigung), sind dem Datenblatt 90261 zu entnehmen.

1) Die Werte sind gültig:

- Bei absolutem Druck PABS = 1 bar am Sauganschluss S

- Für den optimalen Viskositätsbereich von ventscheiden = 36 bis 16 mm2/s

-Für Hydraulikflüssigkeit auf Mineralölbasis.

2) Maximale Drehzahl (Drehzahlgrenze) für erhöhten Einlassdruck PABS an den Sauganschlüssen S und Vg < Vg Max , siehe Abbildung.