Wenzhou Prance Hydraulic Equipment Co., Ltd
A7VO Bent Axis Variable Displacement Pump
The A7VO variable pump uses a bent-axis rotary group for open-circuit drives. Changing its displacement changes delivered flow at a given drive speed. The selected controller must match the pressure, power or flow behavior required by the machine.
- Variable bent-axis rotary group
- Open-circuit hydrostatic drives
- Mobile and stationary applications
- Control devices selected by order code
PRANCE HYDRAULIC · PRODUCT SERIES
Axial piston; bent axis, variable displacement · Open circuit
The A7VO variable pump uses a bent-axis rotary group for open-circuit drives. Changing its displacement changes delivered flow at a given drive speed. The selected controller must match the pressure, power or flow behavior required by the machine.
Model

Confirm the complete model and approved specification with Prance Hydraulic. Product-series references alone do not establish interchangeability.
Configuration review · Technical documentation · Product selection
Detalhes do Produto
- Variable bent-axis rotary group
- Open-circuit hydrostatic drives
- Mobile and stationary applications
- Control devices selected by order code
CATEGORIES: Bomba de pistão, Bomba de caudal variável
A7VO Features & Application
Variable bent-axis rotary group
Specify the displacement range or switching arrangement and verify performance at each required setting.
Open-circuit hydrostatic drives
Review normal running, startup and reversal where applicable. The pressure and flow requirements can differ between operating states.
Mobile and stationary applications
Compare the required flow at the actual drive speed and pressure. Check the selected variant rather than combining maxima from different rows.
Control devices selected by order code
Match the complete control option and its command requirements to the existing controller. Similar housings can use different control arrangements.
A7VO Specifications
| Series / model | A7VO |
|---|---|
| Product type | A7VO Bent Axis Variable Displacement Pump |
| Design | Axial piston; bent axis, variable displacement |
| Circuit / selection | Open circuit |
| Published nominal sizes | 28, 55, 80, 107 and 160 |
| Listed geometric displacement | 28.1, 54.8, 80, 107 and 160 cm³/rev |
A7VO Selection & Configuration
The A7VO variable pump uses a bent-axis rotary group for open-circuit drives. Changing its displacement changes delivered flow at a given drive speed. The selected controller must match the pressure, power or flow behavior required by the machine.
Specify the operating points across the work cycle and compare them with the control characteristic. Verify inlet conditions at the highest flow demand and check the shaft, mounting flange and drain connections against the A7VO drawing.

cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits.
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits.
Hydraulic pumps · Hydraulic motors · Hydraulic valves
Send the MS nameplate, operating requirements and installation drawing for a configuration review before quoting.
- Model review — send the full model code or an existing nameplate photograph.
- Interface matching — confirm shaft, mounting flange, rotation and ports.
- Operating conditions — provide flow, pressure, speed, fluid and duty cycle.
- Documentation — request the relevant product data and drawings for your review.

A7VO Buying Guide
Use this sequence to prepare the A7VO configuration for review and quotation.
- Define required flow at the actual drive speed and continuous pressure.
- Identify peak pressure, duration and the work cycle.
- Confirm the selected displacement control and any auxiliary-drive requirement.
- Match rotation viewed from the shaft end, shaft, flange and ports.
- Review inlet conditions, drain routing and the installation envelope.
- Confirm fluid, viscosity, temperature, filtration and seals.
- Approve the complete model, control, drawing, quantity and delivery terms.

Selection, Documentation & Project Support

Selection Support
Learn more →Share your hydraulic circuit, operating point and installation requirements for a configuration discussion.
Flow · Pressure · Speed · Interfaces

Technical Resources
Learn more →Review product documentation, model codes and technical data before finalizing the specification.
Datasheets · Model codes · Drawings

Project Inquiries
Learn more →Send your required model, quantity, application and project requirements to discuss your inquiry.
Product inquiries · Configuration review
Configuration, Quantity & Delivery
Confirm the complete MS code, approved drawing and operating limits. Availability, quantity, documentation and delivery date are confirmed in the quotation.
Discuss Your A7VO Application
Send the full model code, operating duty, installation details and quantity.
Request a A7VO QuotationA7VO Questions Before Ordering
What type of product is the A7VO?
A7VO Bent Axis Variable Displacement Pump. Design: Axial piston; bent axis, variable displacement. Open circuit. Confirm the complete order code for the offered version.
Can a similar pump replace the A7VO?
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits.
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits
Define required flow at the actual drive speed and continuous pressure. Identify peak pressure, duration and the work cycle. Attach the nameplate, complete order code, installation drawing and required quantity.
A7VO Technical Data & Documents
View A7VO catalog data and operating conditions
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits.
Dados técnicos
| Tamanho | NG | 28 | 55 | 80 | 107 | 160 | ||
| Cilindrada, geométrica, por rotação | Vavóx | cm3 | 28.1 | 54.8 | 80 | 107 | 160 | |
| Velocidade máxima de rotação 1) | À VG Max | nnome | rpm | 3150 | 2500 | 2240 | 2150 | 1900 |
| À Vg<0,74 x Vg máx | nmax1 | rpm | 4250 | 3400 | 3000 | 2900 | 2560 | |
| Velocidade máxima de rotação 2) | nmax2 | rpm | 4750 | 3750 | 3350 | 3200 | 2850 | |
| Rigidez torcional | Vg máx a V g/2 | cmin | kNm/rad | 5 | 10 | 16 | 21 | 36 |
| Vg/2 a 0 (interpolado) | cmáx | kNm/rad | 16 | 32 | 49 | 67 | 104 | |
| Momento de inércia do grupo rotativo | JTW | kgm2 | 0.0042 | 0.0042 | 0.0080 | 0.0127 | 0.0253 | |
| Aceleração angular máxima | α | rad/s2 | 35900 | 31600 | 24200 | 19200 | 15300 | |
| Volume de processos | V | l | 0.5 | 0.75 | 1.2 | 1.5 | 2.4 | |
| Peso (aprox.) | m | kg | 17 | 25 | 40 | 49 | 71 | |
Velocidade máxima admissível (limite de velocidade)
Determinação das características operacionais
Chave
Vg = Deslocamento por rotação [cm3] Δp = Differential pressure [bar] n = Rotational speed [rpm] ηv = Volumetric efficiency ηmh = Hydraulic-mechanical efficiency ηt = Eficiência total (ηt= ηv*ηmh)Notas
▶Theore tical values, without efficiency and tolerances;values rounded ▶Operation above the maximum values or below the minimum values may result in a loss of function, a reduced service life or in the destruction of the axial piston unit. Other permissible limit values, such as speed variation, reduced angular acceleration as a function of the frequency and the permissible angular acceleration at start (lower than the maximum angular acceleration) can be found in data sheet 90261. 1) The values are valid: – At absolute pressure Pabs = 1 bar at suction port S – For the optimal viscosity range of voptar = 36 a 16 mm2/s -For hydraulic fluid based on mineral oils. 2) Maximum rotational speed (speed limit) for increased inlet pressure Pabs na porta de sucção S e Vg < Vg máx , ver diagrama.Related Selection Resources
Request a A7VO Quotation
Tell us your required configuration, quantity and application.
Código de encomenda
| 01 | 02 | 03 | 04 | 05 | 06 | 07 | 08 | 09 | 10 | 11 | 12 | 13 | ||
| A7V | ○ | / | 63 | - | V | B | 01 |
Unidade de pistões axiais
| 01 | Conceito de eixo inclinado, variável, pressão nominal 350 bar, pressão máxima 400 bar | A7V |
Modo de funcionamento
| 02 | Bomba de circuito aberto | ○ |
Tamanho (NG)
| 03 | Deslocamento geométrico V2 (cm 3), ver "Dados técnicos" na página 7 | 28 | 55 | 80 | 107 | 160 |
| Para os tamanhos 250, 355 e 500, consultar a folha de dados 92203 | ||||||
Dispositivo de controlo
| 28 | 55 | 80 | 107 | 160 | |||||
| 04 | Controlador de potência sem anulação de potência | ● | ● | ● | ● | ● | LR | ||
| com corte de pressão | ● | ● | ● | ● | ● | LRD | |||
| com limitador de curso | controlo negativo | Δp = 25 bar | - | ● | ● | ● | ● | LRH1 | |
| com corte por pressão e limitador de curso | controlo negativo | Δp = 25 bar | - | ● | ● | ● | ● | LRDH1 | |
| com corte de pressão e deteção de carga | - | ● | ● | ● | ● | LRDS | |||
| Regulador de potência com anulação de potência hidraulicamente proporcional
(apenas disponível para rotação no sentido horário e com placa de distribuição 02) |
|||||||||
| com deteção de carga | - | ● | ● | - | - | LA1S | |||
| com deteção de carga e comando prioritário hidráulico proporcional LS | - | ● | ● | - | - | LA1S5 | |||
| Controlador de pressão | ● | ● | ● | ● | ● | DR | |||
| comandado à distância | ● | ● | ● | ● | ● | DRG | |||
| com deteção de carga | - | ● | ● | ● | ● | DRS | |||
| Hidráulica de controlo proporcional | Controlo positivo | Δp = 10 bar | ● | ● | ● | ● | ● | HD1 | |
| com corte por pressão, controlado remotamente | Controlo positivo | Δp = 10 bar | ● | ● | ● | ● | ● | HD1G | |
| Controlo elétrico proporcional | Controlo positivo | U=24V | ● | ● | ● | ● | ● | EP2 | |
Séries
| 05 | Série 6, índice 3 | 63 |
Sentido de rotação
| 28 a 160 | ||||
| 06 | Visualizado no veio de transmissão | sentido horário | ● | R |
| sentido anti-horário | ● | L | ||
Material de selagem
| 07 | FKM (fluoroelastómero) | V |
Veio de transmissão
| 28 a 160 | |||
| 08 | Veículo estriado DIN 5480 | ● | Z |
| Veio com chaveta paralela de acordo com a norma DIN 6885 | ● | P | |
Flange de montagem
| 09 | ISO 3019-2; 4 furos | B |
Placa de orifícios para linhas de trabalho
| 10 | orificiums da flange SAE A e S na parte posterior (rosca de fixação métrica) | 01 |
| Orifícios de flange SAE A e S na lateral (disponível apenas para controladores de potência LA1S e LA1S5, rosca de fixação métrica) | 02 |
•= disponível -= não disponível
= programa preferido
| 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | ||
| A7V | ○ | / | 63 | - | V | B | 1 |
Conector para solenóides1)
| 11 | Sem conector (sem solenoide, apenas com controlo hidráulico; sem código) | |
| Conetor moldado DEUTSCH, de 2 pinos - sem díodo supressor | P |
Versão padrão / especial
| 12 | Versão padrão (sem código) | |
| Versão especial | -S |
•= disponível -= não disponível
= programa preferido
Notas
▶Conservação:
-Até 12 meses por defeito
-Até 24 meses de longo prazo
(indicar em texto simples ao encomendar)
Dados técnicos
| Tamanho | NG | 28 | 55 | 80 | 107 | 160 | ||
| Cilindrada, geométrica, por rotação | Vavóx | cm3 | 28.1 | 54.8 | 80 | 107 | 160 | |
| Velocidade máxima de rotação 1) | À VG Max | nnome | rpm | 3150 | 2500 | 2240 | 2150 | 1900 |
| À Vg<0,74 x Vg máx | nmax1 | rpm | 4250 | 3400 | 3000 | 2900 | 2560 | |
| Velocidade máxima de rotação 2) | nmax2 | rpm | 4750 | 3750 | 3350 | 3200 | 2850 | |
| Fluxo | À VG Max e nnome | qv | L/min | 89 | 137 | 179 | 230 | 304 |
| Energia | À VG Max , nnome e Δp = 350 bar | P | kW | 52 | 80 | 105 | 134 | 177 |
| Binário | À VG Max e Δp = 350 bar | T | Nm | 156 | 305 | 446 | 596 | 891 |
| Rigidez torcional | Vg máx a V g/2 | cmin | kNm/rad | 5 | 10 | 16 | 21 | 36 |
| Vg/2 a 0 (interpolado) | cmáx | kNm/rad | 16 | 32 | 49 | 67 | 104 | |
| Momento de inércia do grupo rotativo | JTW | kgm2 | 0.0042 | 0.0042 | 0.0080 | 0.0127 | 0.0253 | |
| Aceleração angular máxima | α | rad/s2 | 35900 | 31600 | 24200 | 19200 | 15300 | |
| Volume de processos | V | l | 0.5 | 0.75 | 1.2 | 1.5 | 2.4 | |
| Peso (aprox.) | m | kg | 17 | 25 | 40 | 49 | 71 | |
Velocidade máxima admissível (limite de velocidade)

Determinação das características operacionais
| Fluxo | qv=(Vg ∙ n ∙ ηv) / 1000 | L/min |
| Binário | T=(Vg ∙ Δp) /(20 ∙ π ∙ ηmh) | Nm |
| Energia | P=(2π ∙ T ∙ n)/60000=(qv ∙ Δp)/(600 ∙ ηt) | kW |
Chave
Vg = Deslocamento por rotação [cm3]
Δp = Pressão diferencial [bar]
n = Velocidade de rotação [rpm]
ηv = Eficiência volumétrica
ηmh = Eficiência hidráulico-mecânica
ηt = Eficiência total (ηt= ηv*ηmh)
Notas
Valores teóricos, sem eficiência e tolerâncias; valores arredondados
▶A operação acima dos valores máximos ou abaixo dos valores mínimos pode resultar numa perda de funcionamento, numa vida útil reduzida ou na destruição da unidade de pistões axiais. Outros valores limite admissíveis, tais como a variação de velocidade, a aceleração angular reduzida em função da frequência e a aceleração angular admissível no arranque (inferior à aceleração angular máxima), podem ser consultados na folha de dados 90261.
1) Os valores são válidos:
- A pressão absoluta Pabs = 1 bar no orifício de aspiração S
- Para o intervalo de viscosidade ideal de voptar = 36 a 16 mm2/s
-Para fluidos hidráulicos à base de óleos minerais.
2) Velocidade máxima de rotação (limite de velocidade) para o aumento da pressão de entrada Pabs na porta de sucção S e Vg < Vg máx , ver diagrama.