The 4WRKE is a two-stage proportional directional valve with main-spool position feedback and integrated electronics. The pilot stage and main stage must be considered together when matching the valve to the required flow range and dynamic response.
- Two-stage pilot-operated construction
- Main-spool electrical position feedback
- Integrated electronics (OBE)
- Spring-centered main spool
PRANCE HYDRAULIC · PRODUCT SERIES
Two-stage pilot-operated valve; main-spool position feedback · Subplate mounting; confirm pilot and drain configuration
The 4WRKE is a two-stage proportional directional valve with main-spool position feedback and integrated electronics. The pilot stage and main stage must be considered together when matching the valve to the required flow range and dynamic response.
Model

Confirm the complete model and approved specification with Prance Hydraulic. Product-series references alone do not establish interchangeability.
Configuration review · Technical documentation · Product selection
Produktdetails
- Two-stage pilot-operated construction
- Main-spool electrical position feedback
- Integrated electronics (OBE)
- Spring-centered main spool
CATEGORIES: Hydraulikventil, Proportionalventil
4WRKE Features & Application
Two-stage pilot-operated construction
Account for pilot or replenishment demand and the relevant pressure limits. Include filtration and the return or drain route in the circuit review.
Main-spool electrical position feedback
Spool feedback concerns the valve position. Confirm whether the machine also requires separate actuator position or pressure feedback.
Integrated electronics (OBE)
Match the complete control option and its command requirements to the existing controller. Similar housings can use different control arrangements.
Spring-centered main spool
Specify the full MS order code, installation drawing and operating duty so the quotation can identify the proposed configuration.
4WRKE Specifications
| Series / model | 4WRKE |
|---|---|
| Product type | cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits |
| Design | Two-stage pilot-operated valve; main-spool position feedback |
| Circuit / selection | Subplate mounting; confirm pilot and drain configuration |
| Published nominal sizes | 10, 16, 25, 27, 32 and 35 |
| Electronics | Integrated OBE; confirm command interface |
4WRKE Selection & Configuration
The 4WRKE is a two-stage proportional directional valve with main-spool position feedback and integrated electronics. The pilot stage and main stage must be considered together when matching the valve to the required flow range and dynamic response.
Supply the pilot-pressure source and drain route as well as the main circuit pressure. Check whether the quoted flow is measured at the same pressure drop as your application, and confirm the command input and connector rather than assuming all OBE variants are equivalent.

cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits.
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits.
Hydraulic pumps · Hydraulic motors · Hydraulic valves
Send the MS nameplate, operating requirements and installation drawing for a configuration review before quoting.
- Model review — send the full model code or an existing nameplate photograph.
- Interface matching — confirm shaft, mounting flange, rotation and ports.
- Operating conditions — provide flow, pressure, speed, fluid and duty cycle.
- Documentation — request the relevant product data and drawings for your review.

4WRKE Buying Guide
Use this sequence to prepare the 4WRKE configuration for review and quotation.
- Select the circuit symbol and required de-energized spool position.
- State working flow, pressure and the pressure-drop condition for rated flow.
- Review spool overlap and command behavior during startup and switch-off.
- Confirm nominal size, subplate pattern, port and seal requirements.
- Match supply voltage, command input, connector and pin assignment.
- Review pilot supply, drain and feedback where the selected valve uses them.
- Approve the exact valve code, circuit drawing, quantity and documentation.

Selection, Documentation & Project Support

Selection Support
Learn more →Share your hydraulic circuit, operating point and installation requirements for a configuration discussion.
Flow · Pressure · Speed · Interfaces

Technical Resources
Learn more →Review product documentation, model codes and technical data before finalizing the specification.
Datasheets · Model codes · Drawings

Project Inquiries
Learn more →Send your required model, quantity, application and project requirements to discuss your inquiry.
Product inquiries · Configuration review
Configuration, Quantity & Delivery
Confirm the complete MS code, approved drawing and operating limits. Availability, quantity, documentation and delivery date are confirmed in the quotation.
Discuss Your 4WRKE Application
Send the full model code, operating duty, installation details and quantity.
Request a 4WRKE Quotation4WRKE Questions Before Ordering
What type of product is the 4WRKE?
4WRKE Proportional Valve with Integrated Electronics. Design: Two-stage pilot-operated valve; main-spool position feedback. Subplate mounting; confirm pilot and drain configuration. Confirm the complete order code for the offered version.
Can a similar valve replace the 4WRKE?
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits.
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits
Select the circuit symbol and required de-energized spool position. State working flow, pressure and the pressure-drop condition for rated flow. Attach the nameplate, complete order code, installation drawing and required quantity.
4WRKE Technical Data & Documents
View 4WRKE catalog data and operating conditions
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits.
Technische Daten
(für Anwendungen außerhalb dieser Parameter sprechen Sie uns bitte an!)Allgemein
| Größen | Größe | 10 | 16 | 25 | 27 | 32 | 35 |
| Einbauort und Inbetriebnahme-Hinweise | Vorzugsweise horizontal, siehe RE 07800 | ||||||
| Lagertemperaturbereich | ℃ | -20 bis +80 | |||||
| Umgebungstemperaturbereich | ℃ | -20 bis +50 | |||||
| Gewicht | kg | 8.7 | 11.2 | 16.8 | 17 | 31.5 | 34 |
| Sinustest nach DIN EN 60068-2-6:2008 1) | 10 cycles, 10…2,000..10 Hz with logarithmic frequency changing speed of 1 oct./min, 5 to 57 Hz, amplitude 1.5 mm (p-p), 57 to 2,000 Hz, amplitude 10 g, 3 axes | ||||||
| Schwingungsprüfung nach DIN EN 60068-2-64:2009 1) | 20...2.000 Hz, Amplitude 0,05 g2/Hz (10 gRMS) 3 axes, testing time 30 min per axis | ||||||
| Schockprüfung nach DIN EN 60068-2-27:2010 1) | Half sine 15 g/11 ms, 3 times in positive and 3 times in negative direction per axis, 3 axes | ||||||
| Feuchte Wärme, zyklisch nach DIN EN 60068-2-30:2006 | Variant 2 +25 ℃ to +55 ℃, 90% to 97% relative humidity, 2 cycles with 24 hours each | ||||||
hydraulisch (gemessen bei p = 100 bar mit HLP46 bei 40 ℃ ± 5 ℃)
| Operating pressure | Vorgabesteuerventil | Steuerölversorgung | Bar | 25 bis 315 | |||||
| Hauptventil, Anschluss P, A, B | Bar | Bis zu 315 | Bis zu 350 | Bis zu 350 | Bis zu 210 | Bis zu 350 | Bis zu 350 | ||
| Return flow pressure | Anschluss T | Steueröl-Ablass, | Bar | Statisch < 10 (Vorsteuerventil) | |||||
| intern | Bar | ||||||||
| Steueröl-Ablass, | Bar | Bis zu 315 | Bis zu 250 | Bis zu 250 | Bis zu 210 | Bis zu 250 | Bis zu 250 | ||
| intern | Bar | ||||||||
| Verbindung Y | Bar | Statisch < 10 (Vorsteuerventil) | |||||||
| NennvolumenstromVnom ± 10% bei Δp = 10 bar (Δp = Druckdifferenz am Ventil) | l/min | - | 125 | - | - | - | - | ||
| 25 | 150 | - | - | - | - | ||||
| 50 | 200 | 220 | - | 400 | - | ||||
| 100 | 220 | 350 | 500 | 600 | 1000 | ||||
| Empfohlener maximaler Durchfluss | l/min | 170 | 460 | 870 | 1000 | 1600 | 3000 | ||
| Steuerölfluss an Anschluss X und/oder Y mit stufenweisem Eingangssignal von 0 bis 100% (315 bar) | l/min | 4.1 | 8.5 | 11.7 | 11.7 | 13.0 | 13.0 | ||
| Hydraulikflüssigkeit | Siehe Tabelle auf Seite 7 | ||||||||
| Maximal zulässiger Verschmutzungsgrad der Hydraulikflüssigkeit, Reinheitsklasse nach ISO 4406 (c) | Vorsteuerventil: Klasse 17/15/12 1) Hauptbühne: Klasse 20/18/15 1) | ||||||||
| Temperaturbereich der Hydraulikflüssigkeit | ℃ | -20 bis +80, vorzugsweise +40 bis +50 | |||||||
| Viskositätsbereich | mm2/s | 20 bis 380, vorzugsweise 30 bis 45 | |||||||
| Hysterese | % | ≤ 1 | |||||||
| Antwortsensitivität | % | ≤ 0,5 | |||||||
| Hydraulikflüssigkeit | Klassifikation | Suitable sealing materials | Standards | |
| Mineralöle und verwandte Kohlenwasserstoffe | HL, HLP | NBR, FKM | DIN 51524 | |
| flammhemmend | -wasserhaltig | HFC (Fuchs HYDROTHERM 46M, Petrofer Ultra Safe 620) | NBR | ISO 12922 |
| Phosphorsäureester | HFD-R | FKM | ||
| Important information on hydraulic fluids! -For more information and data on the use of other hydraulic fluids refer to data sheet 90220 or contact us! -There may be limitations regarding the technical valve data (temperature, pressure range, life cycle, maintenance intervals, etc.)! -The flash point of the process and operating medium used must be 40 K greater than the maximum solenoid surface temperature. – Flame-resistant- containing water: Maximum pressure differential per control edge 175 bar. Pressure pre-loading at the tank port > 20% of the pressure differential; otherwise, increased cavitation. – Life cycle as compared to operation with mineral oil HL,HLP 50% to 100% | ||||
Elektrisch
| Spannungsart | Gleichspannung |
| Signalart | Analog |
| Maximale Leistung | 72 (Durchschnitt = 24 W) |
| Elektrischer Anschluss | Gegenstecker nach DIN EN 175201-804 |
| Schutzart des Ventils nach EN 60529 | IP65 mit montiertem und verriegeltem Gegenstecker |
| Steuerelektronik | Integriert in das Ventil, siehe Seite 8 |
| Steckerbelegung | Kontakt | Signal mit A1 | Signal mit F1 | Signal mit A5 |
| Versorgungsspannung | A | 24 VDC (18 bis 35 VDC); IMax= 1,5 A; Impulslast ≤ 3 A | ||
| B | 0 V | |||
| Referenz (Ist-Wert) | C | Reference potential for actual value (contact “F”) | 4 bis 24 V aktivieren | |
| Differenzverstärkereingang | D | ±10V | 4 bis 20 mA | ±10V |
| Sollwert | E | 0-V-Referenzpotential an Pin D | 0-V-Referenzpotential für Pin D und F | |
| Ausgangswertmessung | F | ±10V | 4 bis 20 mA | ±10V |
| PE | An Kühlelement und Ventilgehäuse angeschlossen | |||
Befehlswert
Reference potential at E and positive command value at D result in flow from P→A and B→T. Reference potential at E and negative command value at D result in flow from P→B and A→ T.Verbindungskabel:
Recommendation: – Up to 25 m line length: Type LiYCY 7×0.75 mm2 – Up to 50 m line length: Type LiYCY 7× 1.0 mm2 Schließen Sie den Schirm nur netzseitig an PE an.Hinweis:
Über die Ventilkleidung (z. B. Istwert) ausgekoppelte elektrische Signale dürfen nicht zum Abschalten sicherheitsrelevanter Maschinenfunktionen verwendet werden!Watch 4WRKE Product Video
Related Selection Resources
Request a 4WRKE Quotation
Tell us your required configuration, quantity and application.
Technische Daten
(für Anwendungen außerhalb dieser Parameter sprechen Sie uns bitte an!)
Allgemein
| Größen | Größe | 10 | 16 | 25 | 27 | 32 | 35 |
| Einbauort und Inbetriebnahme-Hinweise | Vorzugsweise horizontal, siehe RE 07800 | ||||||
| Lagertemperaturbereich | ℃ | -20 bis +80 | |||||
| Umgebungstemperaturbereich | ℃ | -20 bis +50 | |||||
| Gewicht | kg | 8.7 | 11.2 | 16.8 | 17 | 31.5 | 34 |
| Sinustest nach DIN EN 60068-2-6:2008 1) | 10 Zyklen, 10...2.000...10 Hz mit logarithmischer Frequenz Änderungsgeschwindigkeit von 1 Okt./min, 5 bis 57 Hz, Amplitude 1,5 mm (Spitze-Spitze), 57 bis 2.000 Hz, Amplitude 10 g, 3 Achsen |
||||||
| Schwingungsprüfung nach DIN EN 60068-2-64:2009 1) | 20...2.000 Hz, Amplitude 0,05 g2/Hz (10 gRMS) 3 Achsen, Prüfzeit 30 Min. pro Achse |
||||||
| Schockprüfung nach DIN EN 60068-2-27:2010 1) | Halbsinus 15 g/11 ms, je 3-mal positiv und 3-mal negativ negative Richtung pro Achse, 3 Achsen |
||||||
| Feuchte Wärme, zyklisch nach DIN EN 60068-2-30:2006 | Variante 2 +25 °C bis +55 °C, relative Luftfeuchtigkeit 90% bis 97%, 2 Zyklen à 24 Stunden |
||||||
1)Die Angaben zur mechanischen Belastung beziehen sich auf die Befestigungsebene der integrierten Ventilelektronik.
hydraulisch (gemessen bei p = 100 bar mit HLP46 bei 40 ℃ ± 5 ℃)
| Betrieb Druck |
Vorgabesteuerventil | Steuerölversorgung | Bar | 25 bis 315 | |||||
| Hauptventil, Anschluss P, A, B | Bar | Bis zu 315 | Bis zu 350 | Bis zu 350 | Bis zu 210 | Bis zu 350 | Bis zu 350 | ||
| Rückfluss Druck |
Anschluss T | Steueröl-Ablass, | Bar | Statisch < 10 (Vorsteuerventil) | |||||
| intern | Bar | ||||||||
| Steueröl-Ablass, | Bar | Bis zu 315 | Bis zu 250 | Bis zu 250 | Bis zu 210 | Bis zu 250 | Bis zu 250 | ||
| intern | Bar | ||||||||
| Verbindung Y | Bar | Statisch < 10 (Vorsteuerventil) | |||||||
| NennvolumenstromVnom ± 10% bei Δp = 10 bar (Δp = Druckdifferenz am Ventil) | l/min | - | 125 | - | - | - | - | ||
| 25 | 150 | - | - | - | - | ||||
| 50 | 200 | 220 | - | 400 | - | ||||
| 100 | 220 | 350 | 500 | 600 | 1000 | ||||
| Empfohlener maximaler Durchfluss | l/min | 170 | 460 | 870 | 1000 | 1600 | 3000 | ||
| Steuerölfluss an Anschluss X und/oder Y mit stufenweisem Eingangssignal von 0 bis 100% (315 bar) | l/min | 4.1 | 8.5 | 11.7 | 11.7 | 13.0 | 13.0 | ||
| Hydraulikflüssigkeit | Siehe Tabelle auf Seite 7 | ||||||||
| Zulässiger Höchstgrad der Verschmutzung der Hydraulikflüssigkeit – Reinheitsklasse nach ISO 4406 (c) | Vorsteuerventil: Klasse 17/15/12 1) Hauptbühne: Klasse 20/18/15 1) |
||||||||
| Temperaturbereich der Hydraulikflüssigkeit | ℃ | -20 bis +80, vorzugsweise +40 bis +50 | |||||||
| Viskositätsbereich | mm2/s | 20 bis 380, vorzugsweise 30 bis 45 | |||||||
| Hysterese | % | ≤ 1 | |||||||
| Antwortsensitivität | % | ≤ 0,5 | |||||||
1) Die für die Komponenten angegebenen Reinheitsklassen müssen in Hydrauliksystemen eingehalten werden. Effektive Filtration verhindert Störungen und erhöht gleichzeitig die Lebensdauer der Komponenten. Zur Auswahl der Filter siehe www.boschrexroth.com/filter
| Hydraulikflüssigkeit | Klassifikation | Geeignet Dichtungsmaterialien |
Standards | |
| Mineralöle und verwandte Kohlenwasserstoffe | HL, HLP | NBR, FKM | DIN 51524 | |
| flammhemmend | -wasserhaltig | HFC (Fuchs HYDROTHERM 46M), Petrofer Ultra Safe 620 |
NBR | ISO 12922 |
| Phosphorsäureester | HFD-R | FKM | ||
| Wichtige Informationen zu Hydraulikflüssigkeiten! -Für weitere Informationen und Daten zur Verwendung anderer Hydraulikflüssigkeiten siehe Datenblatt 90220 oder kontaktieren Sie uns! -Es kann Einschränkungen hinsichtlich der technischen Ventilatexdaten (Temperatur, Druckbereich, Lebenszyklus, Wartungsintervalle usw.) geben! - Der Flammpunkt des verwendeten Prozess- und Betriebsmediums muss 40 K über der maximalen Magnetoberflächentemperatur liegen. - Flammhemmend – wasserhaltig: Maximaler Druckunterschied pro Steuerkante 175 bar. Druckvorbeladung am Tankanschluss > 20% des Druckunterschieds; andernfalls erhöhte Kavitation. - Lebensdauer im Vergleich zum Betrieb mit Mineralöl HL, HLP 50% bis 100% |
||||
Elektrisch
| Spannungsart | Gleichspannung |
| Signalart | Analog |
| Maximale Leistung | 72 (Durchschnitt = 24 W) |
| Elektrischer Anschluss | Gegenstecker nach DIN EN 175201-804 |
| Schutzart des Ventils nach EN 60529 | IP65 mit montiertem und verriegeltem Gegenstecker |
| Steuerelektronik | Integriert in das Ventil, siehe Seite 8 |
| Steckerbelegung | Kontakt | Signal mit A1 | Signal mit F1 | Signal mit A5 |
| Versorgungsspannung | A | 24 VDC (18 bis 35 VDC); IMax= 1,5 A; Impulslast ≤ 3 A | ||
| B | 0 V | |||
| Referenz (Ist-Wert) | C | Referenzpotential für den Istwert (Kontakt "F") | 4 bis 24 V aktivieren | |
| Differenzverstärkereingang | D | ±10V | 4 bis 20 mA | ±10V |
| Sollwert | E | 0-V-Referenzpotential an Pin D | 0-V-Referenzpotential für Pin D und F | |
| Ausgangswertmessung | F | ±10V | 4 bis 20 mA | ±10V |
| PE | An Kühlelement und Ventilgehäuse angeschlossen | |||
Befehlswert
Das Referenzpotential an E und ein positiver Sollwert an D führen zu einem Fluss von P→A und B→T.
Ein Referenzpotential bei E und ein negativer Sollwert bei D führen zu einer Strömung von P→B und A→T.
Verbindungskabel:
Empfehlung: - Bis 25 m Leitungslänge: Typ LiYCY 7×0,75 mm2
- Bis zu 50 m Leitungslänge: Typ LiYCY 7 × 1,0 mm²2
Schließen Sie den Schirm nur netzseitig an PE an.
Hinweis:
Über die Ventilkleidung (z. B. Istwert) ausgekoppelte elektrische Signale dürfen nicht zum Abschalten sicherheitsrelevanter Maschinenfunktionen verwendet werden!