Wenzhou Prance Hydraulic Equipment Co., Ltd.
4WRZE Pilot Operated Proportional Valve
The 4WRZE pilot-operated proportional valve controls flow direction and flow rate. Its subplate interface and spring-centered spool are part of the existing product description. For a press application, valve selection must be tied to the complete machine hydraulic and control design.
- Pilot-operated directional control
- Subplate mounting
- Spring-centered spool
- Proportional electronics must match the valve code
PRANCE HYDRAULIC · PRODUCT SERIES
Pilot-operated proportional directional valve · Subplate-mounted direction and flow control
The 4WRZE pilot-operated proportional valve controls flow direction and flow rate. Its subplate interface and spring-centered spool are part of the existing product description. For a press application, valve selection must be tied to the complete machine hydraulic and control design.
Model

Confirm the complete model and approved specification with Prance Hydraulic. Product-series references alone do not establish interchangeability.
Configuration review · Technical documentation · Product selection
Produktdetails
- Pilot-operated directional control
- Subplate mounting
- Spring-centered spool
- Proportional electronics must match the valve code
CATEGORIES: Hydraulikventil, Proportionalventil
4WRZE Features & Application
Pilot-operated directional control
Match the complete control option and its command requirements to the existing controller. Similar housings can use different control arrangements.
Subplate mounting
Check pilot diameter, bolt pattern, shaft engagement or port pattern against the approved installation drawing.
Spring-centered spool
Match the circuit symbol, flow condition and mounting interface. The family name alone does not establish the correct spool or electrical option.
Proportional electronics must match the valve code
Match the complete control option and its command requirements to the existing controller. Similar housings can use different control arrangements.
4WRZE Specifications
| Series / model | 4WRZE |
|---|---|
| Product type | 4WRZE Pilot Operated Proportional Valve |
| Design | Pilot-operated proportional directional valve |
| Circuit / selection | Subplate-mounted direction and flow control |
| Montage | Subplate mounting |
| Steuerungsfunktion | Proportional direction and flow; confirm spool and electronics |
4WRZE Selection & Configuration
The 4WRZE pilot-operated proportional valve controls flow direction and flow rate. Its subplate interface and spring-centered spool are part of the existing product description. For a press application, valve selection must be tied to the complete machine hydraulic and control design.
Check pilot supply, drain arrangement, spool overlap and command behavior at startup and switch-off. Do not use the series name as evidence of a safety function. Request the specific valve symbol, pressure-drop condition for rated flow and electrical connection drawing.

cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits.
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits.
Hydraulic pumps · Hydraulic motors · Hydraulic valves
Send the MS nameplate, operating requirements and installation drawing for a configuration review before quoting.
- Model review — send the full model code or an existing nameplate photograph.
- Interface matching — confirm shaft, mounting flange, rotation and ports.
- Operating conditions — provide flow, pressure, speed, fluid and duty cycle.
- Documentation — request the relevant product data and drawings for your review.

4WRZE Buying Guide
Use this sequence to prepare the 4WRZE configuration for review and quotation.
- Select the circuit symbol and required de-energized spool position.
- State working flow, pressure and the pressure-drop condition for rated flow.
- Review spool overlap and command behavior during startup and switch-off.
- Confirm nominal size, subplate pattern, port and seal requirements.
- Match supply voltage, command input, connector and pin assignment.
- Review pilot supply, drain and feedback where the selected valve uses them.
- Approve the exact valve code, circuit drawing, quantity and documentation.

Selection, Documentation & Project Support

Selection Support
Learn more →Share your hydraulic circuit, operating point and installation requirements for a configuration discussion.
Flow · Pressure · Speed · Interfaces

Technical Resources
Learn more →Review product documentation, model codes and technical data before finalizing the specification.
Datasheets · Model codes · Drawings

Project Inquiries
Learn more →Send your required model, quantity, application and project requirements to discuss your inquiry.
Product inquiries · Configuration review
Configuration, Quantity & Delivery
Confirm the complete MS code, approved drawing and operating limits. Availability, quantity, documentation and delivery date are confirmed in the quotation.
Discuss Your 4WRZE Application
Send the full model code, operating duty, installation details and quantity.
Request a 4WRZE Quotation4WRZE Questions Before Ordering
What type of product is the 4WRZE?
4WRZE Pilot Operated Proportional Valve. Design: Pilot-operated proportional directional valve. Subplate-mounted direction and flow control. Confirm the complete order code for the offered version.
Can a similar valve replace the 4WRZE?
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits.
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits
Select the circuit symbol and required de-energized spool position. State working flow, pressure and the pressure-drop condition for rated flow. Attach the nameplate, complete order code, installation drawing and required quantity.
4WRZE Technical Data & Documents
View 4WRZE catalog data and operating conditions
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits.
Technische Daten (für Anwendungen außerhalb dieser Parameter sprechen Sie uns bitte an!)
hydraulisch (gemessen mit HLP46, θÖl= 40 ℃ + 5 ℃ und p = 100 bar)
| Größe | Größe | 10 | 16 | 25 | 32 | 52 | |
| Operating pressure – Pilot control valve | External pilot oil supply Internal pilot oil supply | Bar | 30 bis 100 | 20 bis 100 | |||
| _ | |||||||
| Bar | 100 to 315 only with “D3” | 100 to 350 only with “D3” | |||||
| Hauptventil | Bar | Bis zu 315 | Bis zu 350 | Bis zu 350 | Bis zu 350 | Bis zu 350 | |
| Rücklaufdruck | – Port T (port R) (external pilot oil retum) | Bar | Bis zu 315 | Bis zu 250 | Bis zu 250 | Bis zu 150 | Bis zu 250 |
| – Port T (internal pilot oil return) | Bar | Bis zu 30 | Bis zu 30 | Bis zu 30 | Bis zu 30 | – | |
| – Port Y | Bar | Bis zu 30 | Bis zu 30 | Bis zu 30 | Bis zu 30 | Bis zu 30 | |
| Hauptventil-Durchfluss | l/min | Bis zu 170 | Bis zu 460 | Bis zu 870 | Bis zu 1600 | Bis zu 2800 | |
| Pilotfluss an den Anschlüssen X und Y bei stufenweisem Eingangssignal 0→100% | l/min | 3.5 | 5.5 | 7 | 15.9 | 7 | |
| Pilotvolumen für den Schaltvorgang 0→100% | cm3 | 1.7 | 4.6 | 10 | 26.5 | 54.3 | |
| Hydraulikflüssigkeit | Siehe Tabelle unten | ||||||
| Hydraulikflüssigkeit-Temperaturbereich (an den Ventil-Arbeitsanschlüssen) | ℃ | -20 bis +80 (vorzugsweise +40 bis +50) | |||||
| Viskositätsbereich | mm2/s | 20 bis 380 (vorzugsweise 30 bis 46) | |||||
| Höchstzulässiger Verschmutzungsgrad der Hydraulikflüssigkeit, Reinheitsklasse nach ISO 4406 (c) | |||||||
| – Pilot control valve | Klasse 18/16/13 1) | ||||||
| – Main valve | Klasse 20/18/15 1) | ||||||
| Hysterese | % | ≤6 | |||||
| Hydraulikflüssigkeit | Klassifikation | Suitable sealing materials | Standards | |
| Mineralöle und verwandte Kohlenwasserstoffe | HL, HLP | NBR, FKM | DIN 51524 | |
| flammhemmend | wasserhaltig | HFC (Fuchs HYDROTHERM 46M, Petrofer Ultra Safe 620) | NBR | ISO 12922 |
| Important information on hydraulic fluids! -For more information and data on the use of other hydraulic fluids refer to data sheet 90220 or contact us! -There may be limitations regarding the technical valve data (temperature, pressure range, service life , maintenance intervals, etc.)! -The flash point of the process and operating medium used must be 40 K higher than the maximum solenoid surface temperature. – Flame-resistant- wate-containingr: Maximum pressure differential per control edge 175 bar. Pressure pre-loading at the tank port > 20% of the pressure differential; otherwise, increased cavitation. Life cycle as compared to operation with mineral oil HL,HLP 50% to 100% | ||||
Elektrisch
| Ventiltyp | .WRZ 1) | .WRZE | ||
| Spannungsart | Gleichspannung | |||
| Sollwert-Überlappung | % | 15 | ||
| Maximaler Strom | A | 1.5 | 2.5 | |
| Magnetspulenwiderstand | – Cold value at 20 °C | Ω | 4.8 | 2 |
| – Maximum hot value | Ω | 7.2 | 3 | |
| Einschaltdauer | % | 100 | ||
| Maximale Spulentemperatur 3) | ℃ | 150 | ||
| Schutzart des Ventils nach EN 60529 | IP65 bei montierten und verriegelten Gegensteckern | |||
Steuerelektronik
| Typ 4WRZ | Digitalverstärker im Eurokartenformat 2) | VT-VSPD-1-2X/…according to data sheet 30523 | ||
| Analanger Verstärker im Eurokartenformat 2) mit 1 Ramopenzeit | VT-VSPA2-1-2X/V0/T1, gemäß Datenblatt 30110 | |||
| Analanger Verstärker im Eurokartenformat 2) mit 5 Rampenzeiten | VT-VSPA2-1-2X/V0/T5, gemäß Datenblatt 30110 | |||
| Analog-Modulverstärker 2) | VT-11118-1X/… according to data sheet 30218 | |||
| Typ 4WRZE | Analoger Sollwert-Befehlsgeber 2) | Im Ventil integriert, siehe Seite 14 | ||
| cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits | ||||
| Analoger Sollwert-Befehlsgeber 2) | cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits | |||
| Digitale Sollwertkarte 2) | cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits | |||
| Analoge Sollwertkarte 2) | cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits | |||
| Stromverbrauch | IMax | A | - | 1.8 |
| – Impulse current | A | - | 3 | |
| Führungsgröße | – Voltage input “A1” | V | - | ±10 |
| – Current input “F1” | mA | - | 4 bis 20 | |
Watch 4WRZE Product Video
Related Selection Resources
Request a 4WRZE Quotation
Tell us your required configuration, quantity and application.
Technische Daten (für Anwendungen außerhalb dieser Parameter sprechen Sie uns bitte an!)
hydraulisch (gemessen mit HLP46, θÖl= 40 ℃ + 5 ℃ und p = 100 bar)
| Größe | Größe | 10 | 16 | 25 | 32 | 52 | |
| Betriebsdruck - Vorsteuerventil |
Externe Vorsteuerölversorgung Interne Steuerölversorgung |
Bar | 30 bis 100 | 20 bis 100 | |||
| _ | |||||||
| Bar | 100 bis 315 nur mit "D3" | 100 bis 350 nur mit "D3" | |||||
| Hauptventil | Bar | Bis zu 315 | Bis zu 350 | Bis zu 350 | Bis zu 350 | Bis zu 350 | |
| Rücklaufdruck | - Port T (Port R) (Externer Steuerölrücklauf) |
Bar | Bis zu 315 | Bis zu 250 | Bis zu 250 | Bis zu 150 | Bis zu 250 |
| - Port T (interner Steuerölrücklauf) |
Bar | Bis zu 30 | Bis zu 30 | Bis zu 30 | Bis zu 30 | - | |
| - Hafen Y | Bar | Bis zu 30 | Bis zu 30 | Bis zu 30 | Bis zu 30 | Bis zu 30 | |
| Hauptventil-Durchfluss | l/min | Bis zu 170 | Bis zu 460 | Bis zu 870 | Bis zu 1600 | Bis zu 2800 | |
| Pilotfluss an den Anschlüssen X und Y bei stufenweisem Eingangssignal 0→100% | l/min | 3.5 | 5.5 | 7 | 15.9 | 7 | |
| Pilotvolumen für den Schaltvorgang 0→100% | cm3 | 1.7 | 4.6 | 10 | 26.5 | 54.3 | |
| Hydraulikflüssigkeit | Siehe Tabelle unten | ||||||
| Hydraulikflüssigkeit-Temperaturbereich (an den Ventil-Arbeitsanschlüssen) | ℃ | -20 bis +80 (vorzugsweise +40 bis +50) | |||||
| Viskositätsbereich | mm2/s | 20 bis 380 (vorzugsweise 30 bis 46) | |||||
| Höchstzulässiger Verschmutzungsgrad der Hydraulikflüssigkeit, Reinheitsklasse nach ISO 4406 (c) | |||||||
| - Vorsteuerventil | Klasse 18/16/13 1) | ||||||
| - Hauptventil | Klasse 20/18/15 1) | ||||||
| Hysterese | % | ≤6 | |||||
Die für die Komponenten vorgeschriebenen Sauberkeitsklassen müssen in Hydrauliksystemen eingehalten werden. Eine effektive Filtration verhindert Störungen und erhöht gleichzeitig die Lebensdauer der Komponenten.
| Hydraulikflüssigkeit | Klassifikation | Geeignet Dichtungsmaterialien |
Standards | |
| Mineralöle und verwandte Kohlenwasserstoffe | HL, HLP | NBR, FKM | DIN 51524 | |
| flammhemmend | wasserhaltig | HFC (Fuchs HYDROTHERM 46M, Petrofer Ultra Safe 620) | NBR | ISO 12922 |
| Wichtige Informationen zu Hydraulikflüssigkeiten! -Für weitere Informationen und Daten zur Verwendung anderer Hydraulikflüssigkeiten siehe Datenblatt 90220 oder kontaktieren Sie uns! -Es kann Einschränkungen hinsichtlich der technischen Ventilatexdaten (Temperatur, Druckbereich, Lebenszyklus, Wartungsintervalle usw.) geben! - Der Flammpunkt des verwendeten Prozess- und Betriebsmediums muss 40 K über der maximalen Magnetoberflächentemperatur liegen. - Flammhemmend – wasserhaltig: Der maximale Druckunterschied pro Steuerkante beträgt 175 bar. Die Druckvorspannung am Tankanschluss muss > 20% des Druckunterschieds betragen; andernfalls kommt es zu verstärkter Kavitation. - Lebensdauer im Vergleich zum Betrieb mit Mineralöl HL, HLP 50% bis 100% |
||||
Elektrisch
| Ventiltyp | .WRZ 1) | .WRZE | ||
| Spannungsart | Gleichspannung | |||
| Sollwert-Überlappung | % | 15 | ||
| Maximaler Strom | A | 1.5 | 2.5 | |
| Magnetspulenwiderstand | - Kaltwert bei 20 °C | Ω | 4.8 | 2 |
| - Maximaler Heißwert | Ω | 7.2 | 3 | |
| Einschaltdauer | % | 100 | ||
| Maximale Spulentemperatur 3) | ℃ | 150 | ||
| Schutzart des Ventils nach EN 60529 | IP65 bei montierten und verriegelten Gegensteckern | |||
Steuerelektronik
| Typ 4WRZ | Digitalverstärker im Eurokartenformat 2) | VT-VSPD-1-2X/...gemäß Datenblatt 30523 | ||
| Analanger Verstärker im Eurokartenformat 2) mit 1 Ramopenzeit |
VT-VSPA2-1-2X/V0/T1, gemäß Datenblatt 30110 | |||
| Analanger Verstärker im Eurokartenformat 2) mit 5 Rampenzeiten |
VT-VSPA2-1-2X/V0/T5, gemäß Datenblatt 30110 | |||
| Analog-Modulverstärker 2) | VT-11118-1X/... gemäß Datenblatt 30218 | |||
| Typ 4WRZE | Analoger Sollwert-Befehlsgeber 2) | Im Ventil integriert, siehe Seite 14 | ||
| VT-SWMA-1-1X/... gemäß Datenblatt 29902 | ||||
| Analoger Sollwert-Befehlsgeber 2) | VT-SWMAK-1-1X/... gemäß Datenblatt 29903 | |||
| Digitale Sollwertkarte 2) | VT-HACD-1-1X/... gemäß Datenblatt 30143 | |||
| Analoge Sollwertkarte 2) | VT-SWKA-1-1X/... gemäß Datenblatt 30255 | |||
| Stromverbrauch | IMax | A | - | 1.8 |
| - Stoßstrom | A | - | 3 | |
| Führungsgröße | - Spannungseingang "A1" | V | - | ±10 |
| - Aktuelle Eingabe "F1" | mA | - | 4 bis 20 | |
1) Mit Bosch Rexroth AG Steuerungselektronik
2) Getrennte Bestellung
3) Aufgrund der an den Oberflächen der Magnetspulen auftretenden Temperaturen müssen die europäischen Normen ISO 13732-1 und EN 982 eingehalten werden.