A10VZO Variable Speed Axial Piston Pump

The A10VZO variable pump is listed for start/stop, pressure-holding and multiple-quadrant operation. Its selection should therefore include how the drive behaves during decompression and energy return, not just the maximum delivered flow.

  • Start/stop operation described
  • Pressure-holding duty described
  • First, second and fourth quadrant use
  • Through-drive option subject to configuration
HOME › Hydraulikpumpen › A10VZO

PRANCE HYDRAULIC · PRODUCT SERIES

A10VZO Variable Speed Axial Piston Pump

Axial piston; variable displacement · Confirm the required quadrant and hydraulic circuit

The A10VZO variable pump is listed for start/stop, pressure-holding and multiple-quadrant operation. Its selection should therefore include how the drive behaves during decompression and energy return, not just the maximum delivered flow.

Model

✓A10VZO original product photograph
A10VZOAxial piston; variable displacement
Request a QuotationTechnische Daten & Datenblatt anzeigen

Confirm the complete model and approved specification with Prance Hydraulic. Product-series references alone do not establish interchangeability.

Configuration review · Technical documentation · Product selection

Produktdetails

  • Start/stop operation described
  • Pressure-holding duty described
  • First, second and fourth quadrant use
  • Through-drive option subject to configuration

CATEGORIES: Kolbenpumpe, Verstellpumpe

A10VZO Features & Application

Start/stop operation described

Specify the full MS order code, installation drawing and operating duty so the quotation can identify the proposed configuration.

Pressure-holding duty described

Keep continuous, intermittent and peak conditions separate. Use the row for the selected size and configuration.

First, second and fourth quadrant use

Compare the required flow at the actual drive speed and pressure. Check the selected variant rather than combining maxima from different rows.

Through-drive option subject to configuration

Review combined drive torque and simultaneous demand, including any additional pump connected to the drive.

A10VZO Specifications

Series / modelA10VZO
Product typeA10VZO Variable Speed Axial Piston Pump
DesignAxial piston; variable displacement
Circuit / selectionConfirm the required quadrant and hydraulic circuit
Published nominal sizes3, 6, 8, 10, 18, 28 and 45
Listed maximum geometric displacement3.5, 6, 8, 10.5, 18, 28 and 45 cm³/rev

A10VZO Selection & Configuration

The A10VZO variable pump is listed for start/stop, pressure-holding and multiple-quadrant operation. Its selection should therefore include how the drive behaves during decompression and energy return, not just the maximum delivered flow.

Define the operating quadrants with the drive supplier and identify when hydraulic energy can return to the electric drive. Check lubrication, inlet pressure, control settings and the permitted speed-pressure envelope in each operating state.

cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits

cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits.
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits.

Hydraulic pumps · Hydraulic motors · Hydraulic valves

Send the MS nameplate, operating requirements and installation drawing for a configuration review before quoting.

  • Model review — send the full model code or an existing nameplate photograph.
  • Interface matching — confirm shaft, mounting flange, rotation and ports.
  • Operating conditions — provide flow, pressure, speed, fluid and duty cycle.
  • Documentation — request the relevant product data and drawings for your review.
Prance workshop with a row of production equipment

A10VZO Buying Guide

Use this sequence to prepare the A10VZO configuration for review and quotation.

  1. Define required flow at the actual drive speed and continuous pressure.
  2. Identify peak pressure, duration and the work cycle.
  3. Confirm the selected displacement control and any auxiliary-drive requirement.
  4. Match rotation viewed from the shaft end, shaft, flange and ports.
  5. Review inlet conditions, drain routing and the installation envelope.
  6. Confirm fluid, viscosity, temperature, filtration and seals.
  7. Approve the complete model, control, drawing, quantity and delivery terms.
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits

Selection, Documentation & Project Support

Prance technical team image from its company website

Selection Support

Learn more →

Share your hydraulic circuit, operating point and installation requirements for a configuration discussion.


Flow · Pressure · Speed · Interfaces
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits

Technical Resources

Learn more →

Review product documentation, model codes and technical data before finalizing the specification.


Datasheets · Model codes · Drawings
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits

Project Inquiries

Learn more →

Send your required model, quantity, application and project requirements to discuss your inquiry.


Product inquiries · Configuration review

Configuration, Quantity & Delivery

Confirm the complete MS code, approved drawing and operating limits. Availability, quantity, documentation and delivery date are confirmed in the quotation.

Discuss Your A10VZO Application

Send the full model code, operating duty, installation details and quantity.

Request a A10VZO Quotation

A10VZO Questions Before Ordering

What type of product is the A10VZO?

A10VZO Variable Speed Axial Piston Pump. Design: Axial piston; variable displacement. Confirm the required quadrant and hydraulic circuit. Confirm the complete order code for the offered version.

Can a similar pump replace the A10VZO?

cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits.

cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits

Define required flow at the actual drive speed and continuous pressure. Identify peak pressure, duration and the work cycle. Attach the nameplate, complete order code, installation drawing and required quantity.

A10VZO Technical Data & Documents

View A10VZO catalog data and operating conditions

cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits.

Technische Daten A10VZO Größe 3 bis 45

Größe NG 3 6 8 10 18 28 45
Geometrisches Fördervolumen pro Umdrehung Vg Max cm3 3.5 6 8 10.5 18 28 45
Rotational speed maximum1) bei VG-Max
Saugdrehzahlbetrieb als Pumpe1) nnom U/min 3600 3600 3600 3600 3300 3000 3000
Dekompression mit max. Geschwindigkeit2) nnom U/min 3600 3600 3600 3600 3300 3000 3000
Power Operation as a pump at nnom,VGroßmutterx und Δp = 250 bar P kW 5 10 15 16 – – –
und Δp = 315 bar P kW – – – – 34 39 44
Drehmoment bei VG-Max und Δp = 250 bar T Machs gut 14 24 32 42 – – –
bei VG-Max und Δp = 315 bar T Machs gut – – – – 90 140 225
bei VG-Max und Δp = 100 bar T Machs gut 6 9 13 17 29 140 225
Rotary stiffness of drive shaft S c Nm/rad 8100 8100 8100 8100 – – –
R c Nm/rad – – – – 14800 26300 41000
Trägheitsmoment der Drehgruppe JTW Kgm2 0.0006 0.0006 0.0006 0.0006 0.00093 0.0017 0.0033
Maximale Winkelbeschleunigung2)3) α rad/s2 14000 14000 14000 14000 12600 11200 9500
Fallzahl V L 0.2 0.2 0.2 0.2 0.25 0.3 1.0
Gewicht ohne Durchtrieb (ca. 14N00, 12N00) m kg 8 8 8 8 12 15 27
Gewicht ohne Durchtrieb (22U00 ca.) m kg – – – – – – –
Gewicht mit Durchtrieb (ca. 07K.., 12K..) m kg 10.5 10.5 10.5 10.5 14 18 28
Gewicht mit Durchtrieb (ca. 22U) m kg – – – – – – –

Bestimmung der Betriebskennlinien

Schlüssel

Vg  Fördervolumen pro Umdrehung in [cm3] Δp  Differential pressure [bar] n   Rotational speed [rpm] ηv   Volumetric efficiency ηhm  Hydraulic-mechanical efficiency ηt   Gesamtwirkungsgrad (ηt= ηv*ηhm) 1)The values are applicable: – At absolute pressure PABS = 1 bar at suction port S – For the optimal viscosity range of ventscheiden = 36 bis 16 mm2/s – For hydraulic fluid based on mineral oils 2)Höhere Werte auf Anfrage 3) Der Grenzwert gilt nur für eine einzelne Pumpe, eine Ausführung mit mehreren Pumpen ist auf Anfrage erhältlich. Die Belastbarkeit der Verbindungsteile muss berücksichtigt werden.

Technische Daten A10VZO Größe 71 bis 180

Größe NG 71 100 140 180
Geometrisches Fördervolumen pro Umdrehung Vg Max cm3 71.1 100 140 180
Rotational speed maximum1) bei VG-Max
Saugdrehzahlbetrieb als Pumpe1) nnom U/min 2550 2300 2200 1800
Dekompression mit max. Geschwindigkeit2) nnom U/min Auf Anfrage
Drehmoment bei VG-Max und Δp = 280 bar T Machs gut 317 445 623 801
bei VG-Max und Δp = 100 bar T Machs gut 113 159 223 286
Rotary stiffness of drive shaft S c Nm/rad 8100 8100 8100 8100
R c Nm/rad – 121142 169537 171107
Trägheitsmoment der Drehgruppe JTW Kgm2 0.0087 0.0185 0.0276 0.033
Maximale Winkelbeschleunigung2)3) α rad/s2 7500 6200 5000 4000
Fallzahl V L 1.6 2.2 3.0 2.7
Gewicht ohne Durchtrieb (ca. 12N00, 42N00) m kg 36.5 55 70 –
Gewicht ohne Durchtrieb (22U00 ca.) m kg 47 69 73 78
Gewicht mit Zapfwelle (12K..ca.) m kg – – – –
Gewicht mit Durchtrieb (ca. 22U) m kg 47 69 73 78

Bestimmung der Betriebskennlinien

Schlüssel

Vg  Fördervolumen pro Umdrehung in [cm3] Δp  Differential pressure [bar] n   Rotational speed [rpm] ηv   Volumetric efficiency ηhm  Hydraulic-mechanical efficiency ηt   Gesamtwirkungsgrad (ηt= ηv*ηhm) 1)The values are applicable: – At absolute pressure PABS = 1 bar at suction port S – For the optimal viscosity range of ventscheiden = 36 bis 16 mm2/s – For hydraulic fluid based on mineral oils 2)Höhere Werte auf Anfrage 3) Der Grenzwert gilt nur für eine einzelne Pumpe, eine Ausführung mit mehreren Pumpen ist auf Anfrage erhältlich. Die Belastbarkeit der Verbindungsteile muss berücksichtigt werden. 4) Mit Anschlussplatten 7 oder 14

Zulässige Eingangs- und Durchtriebsdrehmomente

Größe 003 bis 10 18 28 45 71 100 140 180
Eingangsdrehmoment
at drive shaft, maximum2) S TE max Machs gut 126 – – – – 1104 1620 1620
∅ in 3/4 – – – – 1  1/2 1  3/4 1  3/4
R TE max Machs gut – 160 250 400 650 – – –
∅ in – 3/4 7/8 1 1  1/4 – – –
Maximum through- drive torque S max. TD Machs gut 41 – – – – 778 1266 1266
R max. TD Machs gut – 92 127 229 480 – – –

Drehmomentverteilung

cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits
Eingangsdrehmoment TE=T1+T2+T3
TE < TE max
Durchtriebsdrehmoment TD=T2+T3
TD < TD max
1)Effizienz nicht berücksichtigt 2) Für Gelenkwellen ohne Radialkraft
Watch A10VZO Product Video
A10VZO product video

Request a A10VZO Quotation

Tell us your required configuration, quantity and application.

Kontaktformular-Demo
A10VZO original product photograph

Typcode A10VZ0

01 02 03 04 05 06 07 08 09 10 11 12 13
A10V Z ○ / 10 - V C N00

Axialkolbeneinheit

01 Taumelscheibenkonstruktion, variabel A10V

Anwendungsbereich

02 Frequenzumrichter Z

Betriebsart

03 Pumpe, offener Kreisklauf ○

Größe (NG)

04 Geometrisches Fördervolumen, siehe Wertetabelle auf Seite 31 010 018 028 045 071 100 140 180
Andere verfügbare Zwischengrößen 003,006,008

Steuergerät

05 Zweipunktregelung elektrisch U=12V ● ● ● ● ○ ○ ○ ○ EZ3001)
U=24V ● ● ● ● ○ ○ ○ ○ EZ4001)
hydraulisch ● ● ● ● ○ ○ ○ ○ DGO001)
Druckregler hydraulisch ● ● ● ● ○ ○ ○ ○ DRO00
ferngesteuert hydraulisch ● ● ● ● ○ ○ ○ ○ DRGO0
Drehmomentregler Größe 018 bis 180
Beginn der Steuerung

bis zu 50 bar

- ● ● ● ○ ○ ○ ○ LA5D0

51 bis 90 bar

- ● ● ● ○ ○ ○ ○ LA6D0

91 bis 160 bar

- ● ● ● ○ ○ ○ ○ LA7D0

161 bis 240 bar

- ● ● ● ○ ○ ○ ○ LA8D0

über 240 bar

- ● ● ● ○ ○ ○ ○ LA9D0

Serie

06 Serie 1, Index 0 ●

Drehrichtung2)

07 Auf Antriebswelle betrachtet im Uhrzeigersinn R
gegen den Uhrzeigersinn L

Dichtungsmaterial

08 FKM (Fluorelastomer) V

Antriebswelle

09 Kerbwelle

ANSI B92.1a

Standardwelle ● - - - - ○ ○ ○ S
ähnlich wie Welle "S", jedoch für höheres Eingangsdrehmoment - ● ● ● ○ - - - R

Montageflansch

10 ISO 3019-1 (SAE) 2-Loch ● ● ● - - - - - C
4-Loch - - - ● ○ ○ ○ ○ D

1) Bitte geben Sie die mechanische Volumenstromregelung V anG-Max und Vg-Moll im Bestelltext.

2)Änderung der Drehrichtung bei gleicher Druckseite zur Dekompression zulässig

Funktionierender Port3)

003 bis 010 018 028 045 071 100 140 180
11 SAE-Flanschanschlüsse oben und unten, auf gegenüberliegenden Seiten, metrisches Befestigungsgewinde mit universellem Durchtrieb - - - - ○ ○ ○ ○ 22U5)
SAE-Flanschanschlüsse oben und unten, auf gegenüberliegenden Seiten, metrisches Befestigungsgewinde - ● ● ● ○ ○ ○ - 123)5)
DIN 3852-Gewindeanschlüsse hinten, nicht für Durchtrieb ● - - - - - - - 14
DIN 3852 Gewindeanschlüsse auf gegenüberliegender Seite, nur für Durchtrieb ● - - - - - - - 07

Durchfahrt

003 bis 010 018 028 045 071 100 140 180
12 Mit Durchtriebswelle, ohne Nabe, ohne Zwischenflansch;

Befestigungsgewinde metrisch, mit universellem Durchtrieb, nur Steuerkopf 22U

- - - - ○ ○ ○ ○ 004)5)
Ohne Durchtrieb, nur Steuerplatten 12 und 14 ● ● ● ● ○ ○ ○ ○ N00
Anschlussplatte 12 und 07
Flansch ISO 3019-1 Nabe für Keilwelle6)

Durchmesser

Durchmesser Montage7)
82-2 (A) 5/8 Zoll 9T 16/32DP ● ● ● ● - - - - K01
3/4 Zoll 11Z 16/32DP ● ● ● ● - - - - K52
101-2(B) 7/8 Zoll 13Z 16/32DP - - ● ● - - - - K68
1 in 15Z 16/32DP - - - ● - - - - K04
Anschlussplatte 22U
Flansch ISO 3019-1 Nabe für Keilwelle6)

Durchmesser

Durchmesser
82-2 (A) 5/8 Zoll 9T 16/32DP - - - - ○ ○ ○ ○ 01
3/4 Zoll 11Z 16/32DP - - - - ○ ○ ○ ○ 52
101-2(B) 7/8 Zoll 13Z 16/32DP - - - - ○ ○ ○ ○ 68
1 in 15Z 16/32DP - - - - ○ ○ ○ ○ 04
1 1/4 Zoll 14Z 12/24DP - - - - ○ ○ ○ ○ 06
127-4 (C) 1 in 15Z 16/32DP - - - - ○ ○ ○ ○ E2
1 1/4 Zoll 14Z 12/24DP - - - - ○ ○ ○ ○ 15
152-4 (D) 1 1/2 Zoll 17T 12/24DP - - - - - ○ ○ ○ 96
1 3/4 Zoll 13T 8/16DP - - - - - ○ ○ ○ 17

Steckverbinder für Magnetventile

13 ohne, mit Hydrauliksteuerungen 0
HIRSCHMANN-Stecker - ohne Entstördiode H

• = Verfügbar ○ = Auf Anfrage - = Nicht verfügbar

3) Eine stufenlose mechanische Volumenstromregelung ist nur bei der Version 12 N00 in den Baugrößen 018 bis 140 serienmäßig.

Vg MaxBereich V einstellenG-Max bis 50% Vg Max stufenlos

Vg min.Bitte geben Sie den Einstellbereich V ang-Moll bis 40% VG-Max stufenlos, Einstellungen als Klartext anzugeben.

Vg Max und Vg min. Einschränkungen für Durchtrieb an Pumpen mit Steuerscheiben 12K.. und 22U.. können nur über feste Einstellwerte vorgenommen werden, dies ist auch im Klartext anzugeben.

4) Siehe Datenblatt 95581 Universaldurchtrieb

5) Bei der Bestellung der Baugrößen 071 bis 180 mit Anschlußplatte 22 bestellen Sie bitte den entsprechenden Durchtrieb "U"."

Beispiel: A10VZO045DR000/10R-VSD22U01

Bei der Bestellung der Größen 018 bis 045 mit Anschlussplatte 12 bestellen Sie bitte den entsprechenden Durchtrieb mit "K"."

A10VZ0018DR000/10R-VSD12K01

6) Passikrwelle nach ANSI B92.1a (Kerbverzahnte Wellen nach SAE J744)

7) Befestigungslochbild, von der Abtriebsseite aus gesehen mit der Steuerung oben

Technische Daten A10VZO Größe 3 bis 45

Größe NG 3 6 8 10 18 28 45
Geometrisches Fördervolumen pro Umdrehung Vg Max cm3 3.5 6 8 10.5 18 28 45
Drehzahl

Maximum1)

bei VG-Max
Saugdrehzahlbetrieb als Pumpe1) nnom U/min 3600 3600 3600 3600 3300 3000 3000
Dekompression mit max. Geschwindigkeit2) nnom U/min 3600 3600 3600 3600 3300 3000 3000
Fluss bei nnom und VGroßmutterx qv l/min 12.6 21.6 28.8 38 59 84 135
Macht

Betrieb als Pumpe

bei nnom,VGroßmutterx

und Δp = 250 bar P kW 5 10 15 16 - - -
und Δp = 315 bar P kW - - - - 34 39 44
Drehmoment bei VG-Max und Δp = 250 bar T Machs gut 14 24 32 42 - - -
bei VG-Max und Δp = 315 bar T Machs gut - - - - 90 140 225
bei VG-Max und Δp = 100 bar T Machs gut 6 9 13 17 29 140 225
Verdrehsteifigkeit von

Antriebswelle

S c Nm/rad 8100 8100 8100 8100 - - -
R c Nm/rad - - - - 14800 26300 41000
Trägheitsmoment der Drehgruppe JTW Kgm2 0.0006 0.0006 0.0006 0.0006 0.00093 0.0017 0.0033
Maximale Winkelbeschleunigung2)3) α rad/s2 14000 14000 14000 14000 12600 11200 9500
Fallzahl V L 0.2 0.2 0.2 0.2 0.25 0.3 1.0
Gewicht ohne Durchtrieb (ca. 14N00, 12N00) m kg 8 8 8 8 12 15 27
Gewicht ohne Durchtrieb (22U00 ca.) m kg - - - - - - -
Gewicht mit Durchtrieb (ca. 07K.., 12K..) m kg 10.5 10.5 10.5 10.5 14 18 28
Gewicht mit Durchtrieb (ca. 22U) m kg - - - - - - -

Bestimmung der Betriebskennlinien

Fluss qv=(Vg ∙ n ∙ ηv) / 1000 l/min
Drehmoment M=(Vg ∙ Δp) / (20 ∙ π ∙ ηhm) Machs gut
Macht P=(2π ∙ M ∙ n)/60000=(qv ∙ Δp)/(600 ∙ ηt)  kW

Schlüssel

Vg  Fördervolumen pro Umdrehung in [cm3]

Δp Differenzdruck [bar]

n Drehzahl [U/min]

ηv   Volumetrischer Wirkungsgrad

ηhm  Hydraulisch-mechanischer Wirkungsgrad

ηt   Gesamtwirkungsgrad (ηt= ηv*ηhm)

1)Die Werte gelten:

- Bei absolutem Druck PABS = 1 bar am Sauganschluss S

- Für den optimalen Viskositätsbereich von ventscheiden = 36 bis 16 mm2/s

- Für Hydraulikflüssigkeiten auf Mineralölbasis

2)Höhere Werte auf Anfrage

3) Der Grenzwert gilt nur für eine einzelne Pumpe, eine Ausführung mit mehreren Pumpen ist auf Anfrage erhältlich. Die Belastbarkeit der Verbindungsteile muss berücksichtigt werden.

Technische Daten A10VZO Größe 71 bis 180

Größe NG 71 100 140 180
Geometrisches Fördervolumen pro Umdrehung Vg Max cm3 71.1 100 140 180
Drehzahl

Maximum1)

bei VG-Max
Saugdrehzahlbetrieb als Pumpe1) nnom U/min 2550 2300 2200 1800
Dekompression mit max. Geschwindigkeit2) nnom U/min Auf Anfrage
Fluss bei nnom und VGroßmutterx qv l/min 181 230 308 324
Macht

Betrieb als Pumpe

bei nnom,VGroßmutterx

und Δp = 280 bar

 

P

 

kW

 

84 107 143 151
Drehmoment bei VG-Max und Δp = 280 bar T Machs gut 317 445 623 801
bei VG-Max und Δp = 100 bar T Machs gut 113 159 223 286
Verdrehsteifigkeit von

Antriebswelle

S c Nm/rad 8100 8100 8100 8100
R c Nm/rad - 121142 169537 171107
Trägheitsmoment der Drehgruppe JTW Kgm2 0.0087 0.0185 0.0276 0.033
Maximale Winkelbeschleunigung2)3) α rad/s2 7500 6200 5000 4000
Fallzahl V L 1.6 2.2 3.0 2.7
Gewicht ohne Durchtrieb (ca. 12N00, 42N00) m kg 36.5 55 70 -
Gewicht ohne Durchtrieb (22U00 ca.) m kg 47 69 73 78
Gewicht mit Zapfwelle (12K..ca.) m kg - - - -
Gewicht mit Durchtrieb (ca. 22U) m kg 47 69 73 78

Bestimmung der Betriebskennlinien

Fluss qv=(Vg ∙ n ∙ ηv) / 1000 l/min
Drehmoment T=(Vg ∙ Δp) / (20 ∙ π ∙ ηhm) Machs gut
Macht P=(2π ∙ T ∙ n)/60000=(qv ∙ Δp)/(600 ∙ ηt)  kW

Schlüssel

Vg  Fördervolumen pro Umdrehung in [cm3]

Δp Differenzdruck [bar]

n Drehzahl [U/min]

ηv   Volumetrischer Wirkungsgrad

ηhm  Hydraulisch-mechanischer Wirkungsgrad

ηt   Gesamtwirkungsgrad (ηt= ηv*ηhm)

1)Die Werte gelten:

- Bei absolutem Druck PABS = 1 bar am Sauganschluss S

- Für den optimalen Viskositätsbereich von ventscheiden = 36 bis 16 mm2/s

- Für Hydraulikflüssigkeiten auf Mineralölbasis

2)Höhere Werte auf Anfrage

3) Der Grenzwert gilt nur für eine einzelne Pumpe, eine Ausführung mit mehreren Pumpen ist auf Anfrage erhältlich. Die Belastbarkeit der Verbindungsteile muss berücksichtigt werden.

4) Mit Anschlussplatten 7 oder 14

Zulässige Eingangs- und Durchtriebsdrehmomente

Größe 003 bis 10 18 28 45 71 100 140 180
Eingangsdrehmoment
am Antriebswelle,
Maximum 2
S TE max Machs gut 126 - - - - 1104 1620 1620
∅ in 3/4 - - - - 1  1/2 1  3/4 1  3/4
R TE max Machs gut - 160 250 400 650 - - -
∅ in - 3/4 7/8 1 1  1/4 - - -
Maximaler Durchsatz
Antriebsdrehmoment
S max. TD Machs gut 41 - - - - 778 1266 1266
R max. TD Machs gut - 92 127 229 480 - - -

Drehmomentverteilung

Drehmoment an der 1. Pumpe T1
Drehmoment an der 2. Pumpe T2
Drehmoment an der 3. Pumpe T3
Eingangsdrehmoment TE=T1+T2+T3
TE < TE max
Durchtriebsdrehmoment TD=T2+T3
TD < TD max

1)Effizienz nicht berücksichtigt

2) Für Gelenkwellen ohne Radialkraft

A10VZO