Wenzhou Prance Hydraulic Equipment Co., Ltd.
A10VZO Variable Speed Axial Piston Pump
The A10VZO variable pump is listed for start/stop, pressure-holding and multiple-quadrant operation. Its selection should therefore include how the drive behaves during decompression and energy return, not just the maximum delivered flow.
- Start/stop operation described
- Pressure-holding duty described
- First, second and fourth quadrant use
- Through-drive option subject to configuration
PRANCE HYDRAULIC · PRODUCT SERIES
Axial piston; variable displacement · Confirm the required quadrant and hydraulic circuit
The A10VZO variable pump is listed for start/stop, pressure-holding and multiple-quadrant operation. Its selection should therefore include how the drive behaves during decompression and energy return, not just the maximum delivered flow.
Model

Confirm the complete model and approved specification with Prance Hydraulic. Product-series references alone do not establish interchangeability.
Configuration review · Technical documentation · Product selection
Produktdetails
- Start/stop operation described
- Pressure-holding duty described
- First, second and fourth quadrant use
- Through-drive option subject to configuration
CATEGORIES: Kolbenpumpe, Verstellpumpe
A10VZO Features & Application
Start/stop operation described
Specify the full MS order code, installation drawing and operating duty so the quotation can identify the proposed configuration.
Pressure-holding duty described
Keep continuous, intermittent and peak conditions separate. Use the row for the selected size and configuration.
First, second and fourth quadrant use
Compare the required flow at the actual drive speed and pressure. Check the selected variant rather than combining maxima from different rows.
Through-drive option subject to configuration
Review combined drive torque and simultaneous demand, including any additional pump connected to the drive.
A10VZO Specifications
| Series / model | A10VZO |
|---|---|
| Product type | A10VZO Variable Speed Axial Piston Pump |
| Design | Axial piston; variable displacement |
| Circuit / selection | Confirm the required quadrant and hydraulic circuit |
| Published nominal sizes | 3, 6, 8, 10, 18, 28 and 45 |
| Listed maximum geometric displacement | 3.5, 6, 8, 10.5, 18, 28 and 45 cm³/rev |
A10VZO Selection & Configuration
The A10VZO variable pump is listed for start/stop, pressure-holding and multiple-quadrant operation. Its selection should therefore include how the drive behaves during decompression and energy return, not just the maximum delivered flow.
Define the operating quadrants with the drive supplier and identify when hydraulic energy can return to the electric drive. Check lubrication, inlet pressure, control settings and the permitted speed-pressure envelope in each operating state.

cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits.
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits.
Hydraulic pumps · Hydraulic motors · Hydraulic valves
Send the MS nameplate, operating requirements and installation drawing for a configuration review before quoting.
- Model review — send the full model code or an existing nameplate photograph.
- Interface matching — confirm shaft, mounting flange, rotation and ports.
- Operating conditions — provide flow, pressure, speed, fluid and duty cycle.
- Documentation — request the relevant product data and drawings for your review.

A10VZO Buying Guide
Use this sequence to prepare the A10VZO configuration for review and quotation.
- Define required flow at the actual drive speed and continuous pressure.
- Identify peak pressure, duration and the work cycle.
- Confirm the selected displacement control and any auxiliary-drive requirement.
- Match rotation viewed from the shaft end, shaft, flange and ports.
- Review inlet conditions, drain routing and the installation envelope.
- Confirm fluid, viscosity, temperature, filtration and seals.
- Approve the complete model, control, drawing, quantity and delivery terms.

Selection, Documentation & Project Support

Selection Support
Learn more →Share your hydraulic circuit, operating point and installation requirements for a configuration discussion.
Flow · Pressure · Speed · Interfaces

Technical Resources
Learn more →Review product documentation, model codes and technical data before finalizing the specification.
Datasheets · Model codes · Drawings

Project Inquiries
Learn more →Send your required model, quantity, application and project requirements to discuss your inquiry.
Product inquiries · Configuration review
Configuration, Quantity & Delivery
Confirm the complete MS code, approved drawing and operating limits. Availability, quantity, documentation and delivery date are confirmed in the quotation.
Discuss Your A10VZO Application
Send the full model code, operating duty, installation details and quantity.
Request a A10VZO QuotationA10VZO Questions Before Ordering
What type of product is the A10VZO?
A10VZO Variable Speed Axial Piston Pump. Design: Axial piston; variable displacement. Confirm the required quadrant and hydraulic circuit. Confirm the complete order code for the offered version.
Can a similar pump replace the A10VZO?
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits.
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits
Define required flow at the actual drive speed and continuous pressure. Identify peak pressure, duration and the work cycle. Attach the nameplate, complete order code, installation drawing and required quantity.
A10VZO Technical Data & Documents
View A10VZO catalog data and operating conditions
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits.
Technische Daten A10VZO Größe 3 bis 45
| Größe | NG | 3 | 6 | 8 | 10 | 18 | 28 | 45 | ||
| Geometrisches Fördervolumen pro Umdrehung | Vg Max | cm3 | 3.5 | 6 | 8 | 10.5 | 18 | 28 | 45 | |
| Rotational speed maximum1) | bei VG-Max | |||||||||
| Saugdrehzahlbetrieb als Pumpe1) | nnom | U/min | 3600 | 3600 | 3600 | 3600 | 3300 | 3000 | 3000 | |
| Dekompression mit max. Geschwindigkeit2) | nnom | U/min | 3600 | 3600 | 3600 | 3600 | 3300 | 3000 | 3000 | |
| Power Operation as a pump at nnom,VGroßmutterx | und Δp = 250 bar | P | kW | 5 | 10 | 15 | 16 | – | – | – |
| und Δp = 315 bar | P | kW | – | – | – | – | 34 | 39 | 44 | |
| Drehmoment | bei VG-Max und Δp = 250 bar | T | Machs gut | 14 | 24 | 32 | 42 | – | – | – |
| bei VG-Max und Δp = 315 bar | T | Machs gut | – | – | – | – | 90 | 140 | 225 | |
| bei VG-Max und Δp = 100 bar | T | Machs gut | 6 | 9 | 13 | 17 | 29 | 140 | 225 | |
| Rotary stiffness of drive shaft | S | c | Nm/rad | 8100 | 8100 | 8100 | 8100 | – | – | – |
| R | c | Nm/rad | – | – | – | – | 14800 | 26300 | 41000 | |
| Trägheitsmoment der Drehgruppe | JTW | Kgm2 | 0.0006 | 0.0006 | 0.0006 | 0.0006 | 0.00093 | 0.0017 | 0.0033 | |
| Maximale Winkelbeschleunigung2)3) | α | rad/s2 | 14000 | 14000 | 14000 | 14000 | 12600 | 11200 | 9500 | |
| Fallzahl | V | L | 0.2 | 0.2 | 0.2 | 0.2 | 0.25 | 0.3 | 1.0 | |
| Gewicht ohne Durchtrieb (ca. 14N00, 12N00) | m | kg | 8 | 8 | 8 | 8 | 12 | 15 | 27 | |
| Gewicht ohne Durchtrieb (22U00 ca.) | m | kg | – | – | – | – | – | – | – | |
| Gewicht mit Durchtrieb (ca. 07K.., 12K..) | m | kg | 10.5 | 10.5 | 10.5 | 10.5 | 14 | 18 | 28 | |
| Gewicht mit Durchtrieb (ca. 22U) | m | kg | – | – | – | – | – | – | – | |
Bestimmung der Betriebskennlinien
Schlüssel
Vg Fördervolumen pro Umdrehung in [cm3] Δp Differential pressure [bar] n Rotational speed [rpm] ηv Volumetric efficiency ηhm Hydraulic-mechanical efficiency ηt Gesamtwirkungsgrad (ηt= ηv*ηhm) 1)The values are applicable: – At absolute pressure PABS = 1 bar at suction port S – For the optimal viscosity range of ventscheiden = 36 bis 16 mm2/s – For hydraulic fluid based on mineral oils 2)Höhere Werte auf Anfrage 3) Der Grenzwert gilt nur für eine einzelne Pumpe, eine Ausführung mit mehreren Pumpen ist auf Anfrage erhältlich. Die Belastbarkeit der Verbindungsteile muss berücksichtigt werden.Technische Daten A10VZO Größe 71 bis 180
| Größe | NG | 71 | 100 | 140 | 180 | ||
| Geometrisches Fördervolumen pro Umdrehung | Vg Max | cm3 | 71.1 | 100 | 140 | 180 | |
| Rotational speed maximum1) | bei VG-Max | ||||||
| Saugdrehzahlbetrieb als Pumpe1) | nnom | U/min | 2550 | 2300 | 2200 | 1800 | |
| Dekompression mit max. Geschwindigkeit2) | nnom | U/min | Auf Anfrage | ||||
| Drehmoment | bei VG-Max und Δp = 280 bar | T | Machs gut | 317 | 445 | 623 | 801 |
| bei VG-Max und Δp = 100 bar | T | Machs gut | 113 | 159 | 223 | 286 | |
| Rotary stiffness of drive shaft | S | c | Nm/rad | 8100 | 8100 | 8100 | 8100 |
| R | c | Nm/rad | – | 121142 | 169537 | 171107 | |
| Trägheitsmoment der Drehgruppe | JTW | Kgm2 | 0.0087 | 0.0185 | 0.0276 | 0.033 | |
| Maximale Winkelbeschleunigung2)3) | α | rad/s2 | 7500 | 6200 | 5000 | 4000 | |
| Fallzahl | V | L | 1.6 | 2.2 | 3.0 | 2.7 | |
| Gewicht ohne Durchtrieb (ca. 12N00, 42N00) | m | kg | 36.5 | 55 | 70 | – | |
| Gewicht ohne Durchtrieb (22U00 ca.) | m | kg | 47 | 69 | 73 | 78 | |
| Gewicht mit Zapfwelle (12K..ca.) | m | kg | – | – | – | – | |
| Gewicht mit Durchtrieb (ca. 22U) | m | kg | 47 | 69 | 73 | 78 | |
Bestimmung der Betriebskennlinien
Schlüssel
Vg Fördervolumen pro Umdrehung in [cm3] Δp Differential pressure [bar] n Rotational speed [rpm] ηv Volumetric efficiency ηhm Hydraulic-mechanical efficiency ηt Gesamtwirkungsgrad (ηt= ηv*ηhm) 1)The values are applicable: – At absolute pressure PABS = 1 bar at suction port S – For the optimal viscosity range of ventscheiden = 36 bis 16 mm2/s – For hydraulic fluid based on mineral oils 2)Höhere Werte auf Anfrage 3) Der Grenzwert gilt nur für eine einzelne Pumpe, eine Ausführung mit mehreren Pumpen ist auf Anfrage erhältlich. Die Belastbarkeit der Verbindungsteile muss berücksichtigt werden. 4) Mit Anschlussplatten 7 oder 14Zulässige Eingangs- und Durchtriebsdrehmomente
| Größe | 003 bis 10 | 18 | 28 | 45 | 71 | 100 | 140 | 180 | |||
| Eingangsdrehmoment | |||||||||||
| at drive shaft, maximum2) | S | TE max | Machs gut | 126 | – | – | – | – | 1104 | 1620 | 1620 |
| ∅ | in | 3/4 | – | – | – | – | 1 1/2 | 1 3/4 | 1 3/4 | ||
| R | TE max | Machs gut | – | 160 | 250 | 400 | 650 | – | – | – | |
| ∅ | in | – | 3/4 | 7/8 | 1 | 1 1/4 | – | – | – | ||
| Maximum through- drive torque | S | max. TD | Machs gut | 41 | – | – | – | – | 778 | 1266 | 1266 |
| R | max. TD | Machs gut | – | 92 | 127 | 229 | 480 | – | – | – | |
Drehmomentverteilung
| Eingangsdrehmoment | TE=T1+T2+T3 |
| TE < TE max | |
| Durchtriebsdrehmoment | TD=T2+T3 |
| TD < TD max |
Watch A10VZO Product Video
Related Selection Resources
Request a A10VZO Quotation
Tell us your required configuration, quantity and application.
Typcode A10VZ0
| 01 | 02 | 03 | 04 | 05 | 06 | 07 | 08 | 09 | 10 | 11 | 12 | 13 | ||
| A10V | Z | ○ | / | 10 | - | V | C | N00 |
Axialkolbeneinheit
| 01 | Taumelscheibenkonstruktion, variabel | A10V |
Anwendungsbereich
| 02 | Frequenzumrichter | Z |
Betriebsart
| 03 | Pumpe, offener Kreisklauf | ○ |
Größe (NG)
| 04 | Geometrisches Fördervolumen, siehe Wertetabelle auf Seite 31 | 010 | 018 | 028 | 045 | 071 | 100 | 140 | 180 |
| Andere verfügbare Zwischengrößen | 003,006,008 |
Steuergerät
| 05 | Zweipunktregelung | elektrisch | U=12V | ● | ● | ● | ● | ○ | ○ | ○ | ○ | EZ3001) |
| U=24V | ● | ● | ● | ● | ○ | ○ | ○ | ○ | EZ4001) | |||
| hydraulisch | ● | ● | ● | ● | ○ | ○ | ○ | ○ | DGO001) | |||
| Druckregler | hydraulisch | ● | ● | ● | ● | ○ | ○ | ○ | ○ | DRO00 | ||
| ferngesteuert hydraulisch | ● | ● | ● | ● | ○ | ○ | ○ | ○ | DRGO0 | |||
| Drehmomentregler | Größe 018 bis 180 | |||||||||||
| Beginn der Steuerung |
bis zu 50 bar |
- | ● | ● | ● | ○ | ○ | ○ | ○ | LA5D0 | ||
|
51 bis 90 bar |
- | ● | ● | ● | ○ | ○ | ○ | ○ | LA6D0 | |||
|
91 bis 160 bar |
- | ● | ● | ● | ○ | ○ | ○ | ○ | LA7D0 | |||
|
161 bis 240 bar |
- | ● | ● | ● | ○ | ○ | ○ | ○ | LA8D0 | |||
|
über 240 bar |
- | ● | ● | ● | ○ | ○ | ○ | ○ | LA9D0 | |||
Serie
| 06 | Serie 1, Index 0 | ● |
Drehrichtung2)
| 07 | Auf Antriebswelle betrachtet | im Uhrzeigersinn | R |
| gegen den Uhrzeigersinn | L |
Dichtungsmaterial
| 08 | FKM (Fluorelastomer) | V |
Antriebswelle
| 09 | Kerbwelle
ANSI B92.1a |
Standardwelle | ● | - | - | - | - | ○ | ○ | ○ | S |
| ähnlich wie Welle "S", jedoch für höheres Eingangsdrehmoment | - | ● | ● | ● | ○ | - | - | - | R |
Montageflansch
| 10 | ISO 3019-1 (SAE) | 2-Loch | ● | ● | ● | - | - | - | - | - | C |
| 4-Loch | - | - | - | ● | ○ | ○ | ○ | ○ | D |
1) Bitte geben Sie die mechanische Volumenstromregelung V anG-Max und Vg-Moll im Bestelltext.
2)Änderung der Drehrichtung bei gleicher Druckseite zur Dekompression zulässig
Funktionierender Port3)
| 003 bis 010 | 018 | 028 | 045 | 071 | 100 | 140 | 180 | |||
| 11 | SAE-Flanschanschlüsse oben und unten, auf gegenüberliegenden Seiten, metrisches Befestigungsgewinde mit universellem Durchtrieb | - | - | - | - | ○ | ○ | ○ | ○ | 22U5) |
| SAE-Flanschanschlüsse oben und unten, auf gegenüberliegenden Seiten, metrisches Befestigungsgewinde | - | ● | ● | ● | ○ | ○ | ○ | - | 123)5) | |
| DIN 3852-Gewindeanschlüsse hinten, nicht für Durchtrieb | ● | - | - | - | - | - | - | - | 14 | |
| DIN 3852 Gewindeanschlüsse auf gegenüberliegender Seite, nur für Durchtrieb | ● | - | - | - | - | - | - | - | 07 |
Durchfahrt
| 003 bis 010 | 018 | 028 | 045 | 071 | 100 | 140 | 180 | ||||||
| 12 | Mit Durchtriebswelle, ohne Nabe, ohne Zwischenflansch;
Befestigungsgewinde metrisch, mit universellem Durchtrieb, nur Steuerkopf 22U |
- | - | - | - | ○ | ○ | ○ | ○ | 004)5) | |||
| Ohne Durchtrieb, nur Steuerplatten 12 und 14 | ● | ● | ● | ● | ○ | ○ | ○ | ○ | N00 | ||||
| Anschlussplatte 12 und 07 | |||||||||||||
| Flansch ISO 3019-1 | Nabe für Keilwelle6)
Durchmesser |
||||||||||||
| Durchmesser | Montage7) | ||||||||||||
| 82-2 (A) | 5/8 Zoll | 9T 16/32DP | ● | ● | ● | ● | - | - | - | - | K01 | ||
| 3/4 Zoll | 11Z 16/32DP | ● | ● | ● | ● | - | - | - | - | K52 | |||
| 101-2(B) | 7/8 Zoll | 13Z 16/32DP | - | - | ● | ● | - | - | - | - | K68 | ||
| 1 in | 15Z 16/32DP | - | - | - | ● | - | - | - | - | K04 | |||
| Anschlussplatte 22U | |||||||||||||
| Flansch ISO 3019-1 | Nabe für Keilwelle6)
Durchmesser |
||||||||||||
| Durchmesser | |||||||||||||
| 82-2 (A) | 5/8 Zoll | 9T 16/32DP | - | - | - | - | ○ | ○ | ○ | ○ | 01 | ||
| 3/4 Zoll | 11Z 16/32DP | - | - | - | - | ○ | ○ | ○ | ○ | 52 | |||
| 101-2(B) | 7/8 Zoll | 13Z 16/32DP | - | - | - | - | ○ | ○ | ○ | ○ | 68 | ||
| 1 in | 15Z 16/32DP | - | - | - | - | ○ | ○ | ○ | ○ | 04 | |||
| 1 1/4 Zoll | 14Z 12/24DP | - | - | - | - | ○ | ○ | ○ | ○ | 06 | |||
| 127-4 (C) | 1 in | 15Z 16/32DP | - | - | - | - | ○ | ○ | ○ | ○ | E2 | ||
| 1 1/4 Zoll | 14Z 12/24DP | - | - | - | - | ○ | ○ | ○ | ○ | 15 | |||
| 152-4 (D) | 1 1/2 Zoll | 17T 12/24DP | - | - | - | - | - | ○ | ○ | ○ | 96 | ||
| 1 3/4 Zoll | 13T 8/16DP | - | - | - | - | - | ○ | ○ | ○ | 17 | |||
Steckverbinder für Magnetventile
| 13 | ohne, mit Hydrauliksteuerungen | 0 |
| HIRSCHMANN-Stecker - ohne Entstördiode | H |
• = Verfügbar ○ = Auf Anfrage - = Nicht verfügbar
3) Eine stufenlose mechanische Volumenstromregelung ist nur bei der Version 12 N00 in den Baugrößen 018 bis 140 serienmäßig.
Vg MaxBereich V einstellenG-Max bis 50% Vg Max stufenlos
Vg min.Bitte geben Sie den Einstellbereich V ang-Moll bis 40% VG-Max stufenlos, Einstellungen als Klartext anzugeben.
Vg Max und Vg min. Einschränkungen für Durchtrieb an Pumpen mit Steuerscheiben 12K.. und 22U.. können nur über feste Einstellwerte vorgenommen werden, dies ist auch im Klartext anzugeben.
4) Siehe Datenblatt 95581 Universaldurchtrieb
5) Bei der Bestellung der Baugrößen 071 bis 180 mit Anschlußplatte 22 bestellen Sie bitte den entsprechenden Durchtrieb "U"."
Beispiel: A10VZO045DR000/10R-VSD22U01
Bei der Bestellung der Größen 018 bis 045 mit Anschlussplatte 12 bestellen Sie bitte den entsprechenden Durchtrieb mit "K"."
A10VZ0018DR000/10R-VSD12K01
6) Passikrwelle nach ANSI B92.1a (Kerbverzahnte Wellen nach SAE J744)
7) Befestigungslochbild, von der Abtriebsseite aus gesehen mit der Steuerung oben
Technische Daten A10VZO Größe 3 bis 45
| Größe | NG | 3 | 6 | 8 | 10 | 18 | 28 | 45 | ||
| Geometrisches Fördervolumen pro Umdrehung | Vg Max | cm3 | 3.5 | 6 | 8 | 10.5 | 18 | 28 | 45 | |
| Drehzahl
Maximum1) |
bei VG-Max | |||||||||
| Saugdrehzahlbetrieb als Pumpe1) | nnom | U/min | 3600 | 3600 | 3600 | 3600 | 3300 | 3000 | 3000 | |
| Dekompression mit max. Geschwindigkeit2) | nnom | U/min | 3600 | 3600 | 3600 | 3600 | 3300 | 3000 | 3000 | |
| Fluss | bei nnom und VGroßmutterx | qv | l/min | 12.6 | 21.6 | 28.8 | 38 | 59 | 84 | 135 |
| Macht
Betrieb als Pumpe bei nnom,VGroßmutterx |
und Δp = 250 bar | P | kW | 5 | 10 | 15 | 16 | - | - | - |
| und Δp = 315 bar | P | kW | - | - | - | - | 34 | 39 | 44 | |
| Drehmoment | bei VG-Max und Δp = 250 bar | T | Machs gut | 14 | 24 | 32 | 42 | - | - | - |
| bei VG-Max und Δp = 315 bar | T | Machs gut | - | - | - | - | 90 | 140 | 225 | |
| bei VG-Max und Δp = 100 bar | T | Machs gut | 6 | 9 | 13 | 17 | 29 | 140 | 225 | |
| Verdrehsteifigkeit von
Antriebswelle |
S | c | Nm/rad | 8100 | 8100 | 8100 | 8100 | - | - | - |
| R | c | Nm/rad | - | - | - | - | 14800 | 26300 | 41000 | |
| Trägheitsmoment der Drehgruppe | JTW | Kgm2 | 0.0006 | 0.0006 | 0.0006 | 0.0006 | 0.00093 | 0.0017 | 0.0033 | |
| Maximale Winkelbeschleunigung2)3) | α | rad/s2 | 14000 | 14000 | 14000 | 14000 | 12600 | 11200 | 9500 | |
| Fallzahl | V | L | 0.2 | 0.2 | 0.2 | 0.2 | 0.25 | 0.3 | 1.0 | |
| Gewicht ohne Durchtrieb (ca. 14N00, 12N00) | m | kg | 8 | 8 | 8 | 8 | 12 | 15 | 27 | |
| Gewicht ohne Durchtrieb (22U00 ca.) | m | kg | - | - | - | - | - | - | - | |
| Gewicht mit Durchtrieb (ca. 07K.., 12K..) | m | kg | 10.5 | 10.5 | 10.5 | 10.5 | 14 | 18 | 28 | |
| Gewicht mit Durchtrieb (ca. 22U) | m | kg | - | - | - | - | - | - | - | |
Bestimmung der Betriebskennlinien
| Fluss | qv=(Vg ∙ n ∙ ηv) / 1000 | l/min |
| Drehmoment | M=(Vg ∙ Δp) / (20 ∙ π ∙ ηhm) | Machs gut |
| Macht | P=(2π ∙ M ∙ n)/60000=(qv ∙ Δp)/(600 ∙ ηt) | kW |
Schlüssel
Vg Fördervolumen pro Umdrehung in [cm3]
Δp Differenzdruck [bar]
n Drehzahl [U/min]
ηv Volumetrischer Wirkungsgrad
ηhm Hydraulisch-mechanischer Wirkungsgrad
ηt Gesamtwirkungsgrad (ηt= ηv*ηhm)
1)Die Werte gelten:
- Bei absolutem Druck PABS = 1 bar am Sauganschluss S
- Für den optimalen Viskositätsbereich von ventscheiden = 36 bis 16 mm2/s
- Für Hydraulikflüssigkeiten auf Mineralölbasis
2)Höhere Werte auf Anfrage
3) Der Grenzwert gilt nur für eine einzelne Pumpe, eine Ausführung mit mehreren Pumpen ist auf Anfrage erhältlich. Die Belastbarkeit der Verbindungsteile muss berücksichtigt werden.
Technische Daten A10VZO Größe 71 bis 180
| Größe | NG | 71 | 100 | 140 | 180 | ||
| Geometrisches Fördervolumen pro Umdrehung | Vg Max | cm3 | 71.1 | 100 | 140 | 180 | |
| Drehzahl
Maximum1) |
bei VG-Max | ||||||
| Saugdrehzahlbetrieb als Pumpe1) | nnom | U/min | 2550 | 2300 | 2200 | 1800 | |
| Dekompression mit max. Geschwindigkeit2) | nnom | U/min | Auf Anfrage | ||||
| Fluss | bei nnom und VGroßmutterx | qv | l/min | 181 | 230 | 308 | 324 |
| Macht
Betrieb als Pumpe bei nnom,VGroßmutterx |
und Δp = 280 bar
|
P
|
kW
|
84 | 107 | 143 | 151 |
| Drehmoment | bei VG-Max und Δp = 280 bar | T | Machs gut | 317 | 445 | 623 | 801 |
| bei VG-Max und Δp = 100 bar | T | Machs gut | 113 | 159 | 223 | 286 | |
| Verdrehsteifigkeit von
Antriebswelle |
S | c | Nm/rad | 8100 | 8100 | 8100 | 8100 |
| R | c | Nm/rad | - | 121142 | 169537 | 171107 | |
| Trägheitsmoment der Drehgruppe | JTW | Kgm2 | 0.0087 | 0.0185 | 0.0276 | 0.033 | |
| Maximale Winkelbeschleunigung2)3) | α | rad/s2 | 7500 | 6200 | 5000 | 4000 | |
| Fallzahl | V | L | 1.6 | 2.2 | 3.0 | 2.7 | |
| Gewicht ohne Durchtrieb (ca. 12N00, 42N00) | m | kg | 36.5 | 55 | 70 | - | |
| Gewicht ohne Durchtrieb (22U00 ca.) | m | kg | 47 | 69 | 73 | 78 | |
| Gewicht mit Zapfwelle (12K..ca.) | m | kg | - | - | - | - | |
| Gewicht mit Durchtrieb (ca. 22U) | m | kg | 47 | 69 | 73 | 78 | |
Bestimmung der Betriebskennlinien
| Fluss | qv=(Vg ∙ n ∙ ηv) / 1000 | l/min |
| Drehmoment | T=(Vg ∙ Δp) / (20 ∙ π ∙ ηhm) | Machs gut |
| Macht | P=(2π ∙ T ∙ n)/60000=(qv ∙ Δp)/(600 ∙ ηt) | kW |
Schlüssel
Vg Fördervolumen pro Umdrehung in [cm3]
Δp Differenzdruck [bar]
n Drehzahl [U/min]
ηv Volumetrischer Wirkungsgrad
ηhm Hydraulisch-mechanischer Wirkungsgrad
ηt Gesamtwirkungsgrad (ηt= ηv*ηhm)
1)Die Werte gelten:
- Bei absolutem Druck PABS = 1 bar am Sauganschluss S
- Für den optimalen Viskositätsbereich von ventscheiden = 36 bis 16 mm2/s
- Für Hydraulikflüssigkeiten auf Mineralölbasis
2)Höhere Werte auf Anfrage
3) Der Grenzwert gilt nur für eine einzelne Pumpe, eine Ausführung mit mehreren Pumpen ist auf Anfrage erhältlich. Die Belastbarkeit der Verbindungsteile muss berücksichtigt werden.
4) Mit Anschlussplatten 7 oder 14
Zulässige Eingangs- und Durchtriebsdrehmomente
| Größe | 003 bis 10 | 18 | 28 | 45 | 71 | 100 | 140 | 180 | |||
| Eingangsdrehmoment | |||||||||||
| am Antriebswelle, Maximum 2 |
S | TE max | Machs gut | 126 | - | - | - | - | 1104 | 1620 | 1620 |
| ∅ | in | 3/4 | - | - | - | - | 1 1/2 | 1 3/4 | 1 3/4 | ||
| R | TE max | Machs gut | - | 160 | 250 | 400 | 650 | - | - | - | |
| ∅ | in | - | 3/4 | 7/8 | 1 | 1 1/4 | - | - | - | ||
| Maximaler Durchsatz Antriebsdrehmoment |
S | max. TD | Machs gut | 41 | - | - | - | - | 778 | 1266 | 1266 |
| R | max. TD | Machs gut | - | 92 | 127 | 229 | 480 | - | - | - | |
Drehmomentverteilung

| Drehmoment an der 1. Pumpe | T1 |
| Drehmoment an der 2. Pumpe | T2 |
| Drehmoment an der 3. Pumpe | T3 |
| Eingangsdrehmoment | TE=T1+T2+T3 |
| TE < TE max | |
| Durchtriebsdrehmoment | TD=T2+T3 |
| TD < TD max |
1)Effizienz nicht berücksichtigt
2) Für Gelenkwellen ohne Radialkraft







-2.webp)