A10VZO Variable Speed Axial Piston Pump

The A10VZO variable pump is listed for start/stop, pressure-holding and multiple-quadrant operation. Its selection should therefore include how the drive behaves during decompression and energy return, not just the maximum delivered flow.

  • Start/stop operation described
  • Pressure-holding duty described
  • First, second and fourth quadrant use
  • Through-drive option subject to configuration
HOME › Bombas hidráulicas › A10VZO

PRANCE HYDRAULIC · PRODUCT SERIES

A10VZO Variable Speed Axial Piston Pump

Axial piston; variable displacement · Confirm the required quadrant and hydraulic circuit

The A10VZO variable pump is listed for start/stop, pressure-holding and multiple-quadrant operation. Its selection should therefore include how the drive behaves during decompression and energy return, not just the maximum delivered flow.

Model

✓A10VZO original product photograph
A10VZOAxial piston; variable displacement
Request a QuotationVer Datos Técnicos y Ficha Técnica

Confirm the complete model and approved specification with Prance Hydraulic. Product-series references alone do not establish interchangeability.

Configuration review · Technical documentation · Product selection

Detalles del producto

  • Start/stop operation described
  • Pressure-holding duty described
  • First, second and fourth quadrant use
  • Through-drive option subject to configuration

CATEGORIES: Bomba de pistón, Bomba de desplazamiento variable

A10VZO Features & Application

Start/stop operation described

Specify the full MS order code, installation drawing and operating duty so the quotation can identify the proposed configuration.

Pressure-holding duty described

Keep continuous, intermittent and peak conditions separate. Use the row for the selected size and configuration.

First, second and fourth quadrant use

Compare the required flow at the actual drive speed and pressure. Check the selected variant rather than combining maxima from different rows.

Through-drive option subject to configuration

Review combined drive torque and simultaneous demand, including any additional pump connected to the drive.

A10VZO Specifications

Series / modelA10VZO
Product typeA10VZO Variable Speed Axial Piston Pump
DiseñoAxial piston; variable displacement
Circuit / selectionConfirm the required quadrant and hydraulic circuit
Published nominal sizes3, 6, 8, 10, 18, 28 and 45
Listed maximum geometric displacement3.5, 6, 8, 10.5, 18, 28 and 45 cm³/rev

A10VZO Selection & Configuration

The A10VZO variable pump is listed for start/stop, pressure-holding and multiple-quadrant operation. Its selection should therefore include how the drive behaves during decompression and energy return, not just the maximum delivered flow.

Define the operating quadrants with the drive supplier and identify when hydraulic energy can return to the electric drive. Check lubrication, inlet pressure, control settings and the permitted speed-pressure envelope in each operating state.

cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits

cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits.
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits.

Hydraulic pumps · Hydraulic motors · Hydraulic valves

Send the MS nameplate, operating requirements and installation drawing for a configuration review before quoting.

  • Model review — send the full model code or an existing nameplate photograph.
  • Interface matching — confirm shaft, mounting flange, rotation and ports.
  • Operating conditions — provide flow, pressure, speed, fluid and duty cycle.
  • Documentation — request the relevant product data and drawings for your review.
Prance workshop with a row of production equipment

A10VZO Buying Guide

Use this sequence to prepare the A10VZO configuration for review and quotation.

  1. Define required flow at the actual drive speed and continuous pressure.
  2. Identify peak pressure, duration and the work cycle.
  3. Confirm the selected displacement control and any auxiliary-drive requirement.
  4. Match rotation viewed from the shaft end, shaft, flange and ports.
  5. Review inlet conditions, drain routing and the installation envelope.
  6. Confirm fluid, viscosity, temperature, filtration and seals.
  7. Approve the complete model, control, drawing, quantity and delivery terms.
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits

Selection, Documentation & Project Support

Prance technical team image from its company website

Selection Support

Learn more →

Share your hydraulic circuit, operating point and installation requirements for a configuration discussion.


Flow · Pressure · Speed · Interfaces
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits

Technical Resources

Learn more →

Review product documentation, model codes and technical data before finalizing the specification.


Datasheets · Model codes · Drawings
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits

Project Inquiries

Learn more →

Send your required model, quantity, application and project requirements to discuss your inquiry.


Product inquiries · Configuration review

Configuration, Quantity & Delivery

Confirm the complete MS code, approved drawing and operating limits. Availability, quantity, documentation and delivery date are confirmed in the quotation.

Discuss Your A10VZO Application

Send the full model code, operating duty, installation details and quantity.

Request a A10VZO Quotation

A10VZO Questions Before Ordering

What type of product is the A10VZO?

A10VZO Variable Speed Axial Piston Pump. Design: Axial piston; variable displacement. Confirm the required quadrant and hydraulic circuit. Confirm the complete order code for the offered version.

Can a similar pump replace the A10VZO?

cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits.

cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits

Define required flow at the actual drive speed and continuous pressure. Identify peak pressure, duration and the work cycle. Attach the nameplate, complete order code, installation drawing and required quantity.

A10VZO Technical Data & Documents

View A10VZO catalog data and operating conditions

cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits.

Datos técnicos A10VZO tamaño 3 a 45

Tamaño NG 3 6 8 10 18 28 45
Desplazamiento, geométrico, por revolución Vg máx cm3 3.5 6 8 10.5 18 28 45
Rotational speed maximum1) a las VG máximo
Operación de velocidad de succión como bomba1) nNombre rpm 3600 3600 3600 3600 3300 3000 3000
Operación de descompresión a velocidad máx.2) nNombre rpm 3600 3600 3600 3600 3300 3000 3000
Power Operation as a pump at nNombre,Vabuelitax y Δp = 250 bar P kW 5 10 15 16 – – –
y Δp = 315 bar P kW – – – – 34 39 44
Par de torsión a las VG máximo y Δp = 250 bar T Nm 14 24 32 42 – – –
a las VG máximo y Δp = 315 bar T Nm – – – – 90 140 225
a las VG máximo y Δp = 100 bar T Nm 6 9 13 17 29 140 225
Rotary stiffness of drive shaft S c Nm/rad 8100 8100 8100 8100 – – –
R c Nm/rad – – – – 14800 26300 41000
Momento de inercia para el grupo rotativo JTW Kgm2 0.0006 0.0006 0.0006 0.0006 0.00093 0.0017 0.0033
Aceleración angular máxima2)3) α rad/s2 14000 14000 14000 14000 12600 11200 9500
Volumen de casos V L 0.2 0.2 0.2 0.2 0.25 0.3 1.0
Peso sin eje pasante (14N00, 12N00 aprox.) m kg 8 8 8 8 12 15 27
Peso sin transmisión pasante (22U00 aprox.) m kg – – – – – – –
Peso con transmisión pasante (07K.., aprox. 12K..) m kg 10.5 10.5 10.5 10.5 14 18 28
Peso con accionamiento pasante (22U.. aprox.) m kg – – – – – – –

Determinación de las características de funcionamiento

Clave

Vg  Cilindrada por revolución en [cm3] Δp  Differential pressure [bar] n   Rotational speed [rpm] ηv   Volumetric efficiency ηhm  Hydraulic-mechanical efficiency ηt   Eficiencia total (ηt= ηv*ηhm) 1)The values are applicable: – At absolute pressure Pabdominales = 1 bar at suction port S – For the optimal viscosity range of velegir = 36 a 16 mm2/s – For hydraulic fluid based on mineral oils 2)Valores más altos a petición 3) El valor límite solo es válido para una sola bomba, versión para múltiples bombas disponible bajo petición. Se debe tener en cuenta la capacidad de carga de las piezas de conexión.

Datos técnicos A10VZO tamaño 71 a 180

Tamaño NG 71 100 140 180
Desplazamiento, geométrico, por revolución Vg máx cm3 71.1 100 140 180
Rotational speed maximum1) a las VG máximo
Operación de velocidad de succión como bomba1) nNombre rpm 2550 2300 2200 1800
Operación de descompresión a velocidad máx.2) nNombre rpm A petición
Par de torsión a las VG máximo y Δp = 280 bar T Nm 317 445 623 801
a las VG máximo y Δp = 100 bar T Nm 113 159 223 286
Rotary stiffness of drive shaft S c Nm/rad 8100 8100 8100 8100
R c Nm/rad – 121142 169537 171107
Momento de inercia para el grupo rotativo JTW Kgm2 0.0087 0.0185 0.0276 0.033
Aceleración angular máxima2)3) α rad/s2 7500 6200 5000 4000
Volumen de casos V L 1.6 2.2 3.0 2.7
Peso sin accionamiento pasante (aprox. 12N00, 42N00) m kg 36.5 55 70 –
Peso sin transmisión pasante (22U00 aprox.) m kg 47 69 73 78
Peso con transmisión pasante (12K aprox.) m kg – – – –
Peso con accionamiento pasante (22U.. aprox.) m kg 47 69 73 78

Determinación de las características de funcionamiento

Clave

Vg  Cilindrada por revolución en [cm3] Δp  Differential pressure [bar] n   Rotational speed [rpm] ηv   Volumetric efficiency ηhm  Hydraulic-mechanical efficiency ηt   Eficiencia total (ηt= ηv*ηhm) 1)The values are applicable: – At absolute pressure Pabdominales = 1 bar at suction port S – For the optimal viscosity range of velegir = 36 a 16 mm2/s – For hydraulic fluid based on mineral oils 2)Valores más altos a petición 3) El valor límite solo es válido para una sola bomba, versión para múltiples bombas disponible bajo petición. Se debe tener en cuenta la capacidad de carga de las piezas de conexión. 4) Con placas de puerto 7 o 14

Par de entrada admisible y par a través del eje

Tamaño 003 al 10 18 28 45 71 100 140 180
Par de entrada
at drive shaft, maximum2) S TE máx Nm 126 – – – – 1104 1620 1620
∅ en 3/4 – – – – 1  1/2 1  3/4 1  3/4
R TE máx Nm – 160 250 400 650 – – –
∅ en – 3/4 7/8 1 1  1/4 – – –
Maximum through- drive torque S TD máx Nm 41 – – – – 778 1266 1266
R TD máx Nm – 92 127 229 480 – – –

Distribución de pares

cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits
Par de entrada TE=T1+T2+T3
TE < TE máx
Par de arrastre pasante TD=T2+T3
TD < TD máx
1)Eficiencia no considerada 2) Para árboles de transmisión sin fuerza radial
Watch A10VZO Product Video
A10VZO product video

Request a A10VZO Quotation

Tell us your required configuration, quantity and application.

Demostración de formulario de contacto
A10VZO original product photograph

Escriba el código A10VZ0

01 02 03 04 05 06 07 08 09 10 11 12 13
A10V Z ○ / 10 - V C N00

Unidad de pistones axiales

01 Diseño de plato cíclico variable A10V

Área de aplicación

02 Variadores de velocidad Z

Modo de operación

03 Bomba de circuito abierto ○

Tamaño (NG)

04 Desplazamiento geométrico, ver tabla de valores en la página 31 010 018 028 045 071 100 140 180
Otros tamaños intermedios disponibles 003,006,008

Dispositivo de control

05 Control de dos puntos eléctrico U=12V ● ● ● ● ○ ○ ○ ○ EZ3001)
U=24V ● ● ● ● ○ ○ ○ ○ EZ4001)
hidráulico ● ● ● ● ○ ○ ○ ○ DGO001)
Regulador de presión hidráulico ● ● ● ● ○ ○ ○ ○ DRO00
controlado por remoto hidráulicamente ● ● ● ● ○ ○ ○ ○ DRGO0
Controlador de par Talla 018 a 180
Inicio del control

hasta 50 bar

- ● ● ● ○ ○ ○ ○ LA5D0

de 51 a 90 bar

- ● ● ● ○ ○ ○ ○ LA6D0

91 a 160 bar

- ● ● ● ○ ○ ○ ○ LA7D0

161 a 240 bar

- ● ● ● ○ ○ ○ ○ LA8D0

más de 240 bares

- ● ● ● ○ ○ ○ ○ LA9D0

Series

06 Serie 1, índice 0 ●

Sentido de giro2)

07 Visto en el árbol de transmisión en el sentido de las agujas del reloj R
en sentido contrario a las agujas del reloj L

Material de sellado

08 FKM (fluoroelastómero) V

Árbol de transmisión

09 Eje ranurado

ANSI B92.1a

eje estándar ● - - - - ○ ○ ○ S
similar al eje "S" pero para mayor par de entrada - ● ● ● ○ - - - R

Brida de montaje

10 ISO 3019-1 (SAE) de 2 agujeros ● ● ● - - - - - C
de 4 agujeros - - - ● ○ ○ ○ ○ D

1) Por favor, especifique el control de flujo mecánico VG máximo y Vg min en el texto del pedido.

2)Permitido el cambio de sentido de giro con el mismo lado de presión para la descompresión

Puerto de trabajo3)

003 al 010 018 028 045 071 100 140 180
11 Puertos de brida SAE arriba y abajo, en lados opuestos, rosca de fijación métrica con avance pasante universal - - - - ○ ○ ○ ○ 22U5)
Puertos de brida SAE arriba y abajo, en lados opuestos, rosca de fijación métrica - ● ● ● ○ ○ ○ - 123)5)
Puertos roscados DIN 3852 en la parte trasera, no aptos para transmisión pasante ● - - - - - - - 14
Puertos roscados DIN 3852 en el lado opuesto, solo para transmisión pasante ● - - - - - - - 07

A través de la unidad

003 al 010 018 028 045 071 100 140 180
12 Con eje pasante, sin cubo, sin brida intermedia;

rosca de fijación métrica, con eje pasante universal, solo placa de orificios 22U

- - - - ○ ○ ○ ○ 004)5)
Sin eje pasante, solo placas de orificio 12 y 14 ● ● ● ● ○ ○ ○ ○ N00
Placa de orificio 12 y 07
Brida ISO 3019-1 Cubo para eje ranurado6)

Diámetro

Diámetro Montaje7)
82-2 (A) 5/8 pulgada 9T 16/32DP ● ● ● ● - - - - K01
3/4 pulg. 11T 16/32DP ● ● ● ● - - - - K52
101-2(B) 7/8 pulg 13T 16/32DP - - ● ● - - - - K68
1 pulgada 15T 16/32DP - - - ● - - - - K04
Placa de orificios 22U
Brida ISO 3019-1 Cubo para eje ranurado6)

Diámetro

Diámetro
82-2 (A) 5/8 pulgadas 9T 16/32DP - - - - ○ ○ ○ ○ 01
3/4 pulg. 11T 16/32DP - - - - ○ ○ ○ ○ 52
101-2(B) 7/8 pulg 13T 16/32DP - - - - ○ ○ ○ ○ 68
1 pulgada 15T 16/32DP - - - - ○ ○ ○ ○ 04
1 1/4 pulg. 14T 12/24DP - - - - ○ ○ ○ ○ 06
127-4 (C) 1 pulgada 15T 16/32DP - - - - ○ ○ ○ ○ E2
1 1/4 pulg. 14T 12/24DP - - - - ○ ○ ○ ○ 15
152-4 (D) 1 1/2 pulgadas 17T 12/24DP - - - - - ○ ○ ○ 96
1 3/4 pulgadas 13T 8/16DP - - - - - ○ ○ ○ 17

Conectores para solenoides

13 sin, con controladores hidráulicos 0
Conector HIRSCHMANN - sin diodo supresor H

•= Disponible ○ = Bajo petición - = No disponible

3) Un control de caudal mecánico continuo solo es de serie en la versión 12 N00 en los tamaños 018 a 140

Vg máx: Configuración de rango VG máximo a 50% Vg máx continuo

Vg mín: Especifique el rango de configuración Vg min a 40% VG máximo continuo, ajustes a especificar en texto plano.

Vg máx y Vg mín Las limitaciones en transmisiones directas con placas de orificio 12K.. y 22U.. solo se pueden llevar a cabo mediante valores de consigna fijos; esto también debe especificarse en texto claro.

4) Ver hoja de datos 95581 de accionamiento pasante universal

5) Al pedir los tamaños 071 a 180 con la placa deorifice 22, solicite el accionamiento pasivo "U" correspondiente"

A10VZO045DR000/10R-VSD22U01

Al pedir los tamaños 018 a 045 con la placa deorifice 12, solicite el accionamiento pasivo correspondiente con "K"

A10VZ0018DR000/10R-VSD12K01

6) Eje estriado según norma ANSI B92.1a (ejes estriados según SAE J744)

7) Patrón de orificios de montaje visto desde el lado del accionamiento con el control en la parte superior

Datos técnicos A10VZO tamaño 3 a 45

Tamaño NG 3 6 8 10 18 28 45
Desplazamiento, geométrico, por revolución Vg máx cm3 3.5 6 8 10.5 18 28 45
Velocidad de giro

máximo1)

a las VG máximo
Operación de velocidad de succión como bomba1) nNombre rpm 3600 3600 3600 3600 3300 3000 3000
Operación de descompresión a velocidad máx.2) nNombre rpm 3600 3600 3600 3600 3300 3000 3000
Flujo en yNombre y Vabuelitax qv l/min 12.6 21.6 28.8 38 59 84 135
Poder

Funcionamiento como bomba

en yNombre,Vabuelitax

y Δp = 250 bar P kW 5 10 15 16 - - -
y Δp = 315 bar P kW - - - - 34 39 44
Par de torsión a las VG máximo y Δp = 250 bar T Nm 14 24 32 42 - - -
a las VG máximo y Δp = 315 bar T Nm - - - - 90 140 225
a las VG máximo y Δp = 100 bar T Nm 6 9 13 17 29 140 225
Rigidez rotacional de

eje de transmisión

S c Nm/rad 8100 8100 8100 8100 - - -
R c Nm/rad - - - - 14800 26300 41000
Momento de inercia para el grupo rotativo JTW Kgm2 0.0006 0.0006 0.0006 0.0006 0.00093 0.0017 0.0033
Aceleración angular máxima2)3) α rad/s2 14000 14000 14000 14000 12600 11200 9500
Volumen de casos V L 0.2 0.2 0.2 0.2 0.25 0.3 1.0
Peso sin eje pasante (14N00, 12N00 aprox.) m kg 8 8 8 8 12 15 27
Peso sin transmisión pasante (22U00 aprox.) m kg - - - - - - -
Peso con transmisión pasante (07K.., aprox. 12K..) m kg 10.5 10.5 10.5 10.5 14 18 28
Peso con accionamiento pasante (22U.. aprox.) m kg - - - - - - -

Determinación de las características de funcionamiento

Flujo qv=(Vg ∙ n ∙ ηv) / 1000 l/min
Par de torsión M=(Vg ∙ Δp) / (20 ∙ π ∙ ηhm) Nm
Poder P=(2π ∙ M ∙ n)/60000=(qv ∙ Δp)/(600 ∙ ηt)  kW

Clave

Vg  Cilindrada por revolución en [cm3]

Δp Presión diferencial [bar]

n   Velocidad de giro [rpm]

ηv   Eficiencia volumétrica

ηhm  Rendimiento hidráulico-mecánico

ηt   Eficiencia total (ηt= ηv*ηhm)

1)Los valores son aplicables:

- A presión absoluta Pabdominales = 1 bar en el puerto de aspiración S

- Para el rango de viscosidad óptimo de velegir = 36 a 16 mm2/s

- Para fluido hidráulico a base de aceites minerales

2)Valores más altos a petición

3) El valor límite solo es válido para una sola bomba, versión para múltiples bombas disponible bajo petición. Se debe tener en cuenta la capacidad de carga de las piezas de conexión.

Datos técnicos A10VZO tamaño 71 a 180

Tamaño NG 71 100 140 180
Desplazamiento, geométrico, por revolución Vg máx cm3 71.1 100 140 180
Velocidad de giro

máximo1)

a las VG máximo
Operación de velocidad de succión como bomba1) nNombre rpm 2550 2300 2200 1800
Operación de descompresión a velocidad máx.2) nNombre rpm A petición
Flujo en yNombre y Vabuelitax qv l/min 181 230 308 324
Poder

Funcionamiento como bomba

en yNombre,Vabuelitax

y Δp = 280 bar

 

P

 

kW

 

84 107 143 151
Par de torsión a las VG máximo y Δp = 280 bar T Nm 317 445 623 801
a las VG máximo y Δp = 100 bar T Nm 113 159 223 286
Rigidez rotacional de

eje de transmisión

S c Nm/rad 8100 8100 8100 8100
R c Nm/rad - 121142 169537 171107
Momento de inercia para el grupo rotativo JTW Kgm2 0.0087 0.0185 0.0276 0.033
Aceleración angular máxima2)3) α rad/s2 7500 6200 5000 4000
Volumen de casos V L 1.6 2.2 3.0 2.7
Peso sin accionamiento pasante (aprox. 12N00, 42N00) m kg 36.5 55 70 -
Peso sin transmisión pasante (22U00 aprox.) m kg 47 69 73 78
Peso con transmisión pasante (12K aprox.) m kg - - - -
Peso con accionamiento pasante (22U.. aprox.) m kg 47 69 73 78

Determinación de las características de funcionamiento

Flujo qv=(Vg ∙ n ∙ ηv) / 1000 l/min
Par de torsión T=(Vg ∙ Δp) / (20 ∙ π ∙ ηhm) Nm
Poder P=(2π ∙ T ∙ n)/60000=(qv ∙ Δp)/(600 ∙ ηt)  kW

Clave

Vg  Cilindrada por revolución en [cm3]

Δp Presión diferencial [bar]

n   Velocidad de giro [rpm]

ηv   Eficiencia volumétrica

ηhm  Rendimiento hidráulico-mecánico

ηt   Eficiencia total (ηt= ηv*ηhm)

1)Los valores son aplicables:

- A presión absoluta Pabdominales = 1 bar en el puerto de aspiración S

- Para el rango de viscosidad óptimo de velegir = 36 a 16 mm2/s

- Para fluido hidráulico a base de aceites minerales

2)Valores más altos a petición

3) El valor límite solo es válido para una sola bomba, versión para múltiples bombas disponible bajo petición. Se debe tener en cuenta la capacidad de carga de las piezas de conexión.

4) Con placas de puerto 7 o 14

Par de entrada admisible y par a través del eje

Tamaño 003 al 10 18 28 45 71 100 140 180
Par de entrada
en el árbol de transmisión,
máximo2)
S TE máx Nm 126 - - - - 1104 1620 1620
∅ en 3/4 - - - - 1  1/2 1  3/4 1  3/4
R TE máx Nm - 160 250 400 650 - - -
∅ en - 3/4 7/8 1 1  1/4 - - -
Máximo rendimiento a través de
par de apriete
S TD máx Nm 41 - - - - 778 1266 1266
R TD máx Nm - 92 127 229 480 - - -

Distribución de pares

Par en la 1.ª bomba T1
Par en la segunda bomba T2
Par en la tercera bomba T3
Par de entrada TE=T1+T2+T3
TE < TE máx
Par de arrastre pasante TD=T2+T3
TD < TD máx

1)Eficiencia no considerada

2) Para árboles de transmisión sin fuerza radial

A10VZO