Variable Axial Pump A10VZO

1.Suitable for start/stop operations

2.Suitable for long-term pressure holding operations

3.Well-tried A10 rotary assembly technology

4.optional through-shaft drive

5.high efficiency

6.for first, second and fourth quadrant operations

Descrição detalhada

This hydraulic pump is designed with excellent adaptability to various working conditions, being fully suitable for frequent start/stop operations without affecting its service life or performance stability, which makes it ideal for scenarios requiring intermittent operation. It also performs reliably in long-term pressure holding operations, maintaining stable pressure output for extended periods without obvious pressure loss, effectively meeting the requirements of systems that need continuous pressure retention. The pump adopts well-tried and mature A10 rotary assembly technology, which has been verified through long-term practical application, ensuring high operational stability, low failure rate and easy maintenance. For enhanced versatility, it offers an optional through-shaft drive, allowing flexible connection with other components and expanding its application scope in complex hydraulic systems. Additionally, the pump features high efficiency, which can effectively convert input power into hydraulic energy, reducing energy consumption and improving the overall operational efficiency of the system. It is also compatible with first, second and fourth quadrant operations, enabling bidirectional energy flow and adapting to diverse motion control requirements of hydraulic drives.

Seleção e Consulta (RFQ)

Esta série de produtos deve ser selecionada em função do circuito hidráulico aprovado. Confirme o caudal ou a cilindrada necessários, a pressão contínua e de pico, a velocidade de acionamento, o tipo de controlo, o fluido e a interface de instalação antes da seleção final.

Informação a incluir no seu pedido de cotação

  • Cilindrada ou caudal necessários à velocidade de funcionamento
  • Pressão do sistema contínua e de pico
  • Velocidade do acionamento, requisito de controlo e tipo de circuito
  • Flange de fixação, veio, pórticos, requisitos de fluido e filtração

Recursos relacionados

Pedir um orçamento · Centro de transferências · OEM / ODM

Type code A10VZ0

01 02 03 04 05 06 07 08 09 10 11 12 13
A10V Z / 10 - V C N00

Unidade de pistões axiais

01 Swashplate design, variable A10V

Application area

02 Variable-speed drives Z

Modo de funcionamento

03 Bomba de circuito aberto

Tamanho (NG)

04 Geometric displacement, see table of values on page 31 010 018 028 045 071 100 140 180
Other available intermediate sizes 003,006,008

Dispositivo de controlo

05 Two-point control elétrico U=12V EZ3001)
U=24V EZ4001)
hidráulico DGO001)
Controlador de pressão hidráulico DRO00
remote controlled hydraulically DRGO0
Torque controller Size 018 to 180
Início do controlo

up to 50 bar

- LA5D0

51 a 90 bar

- LA6D0

91 a 160 bar

- LA7D0

161 a 240 bar

- LA8D0

over 240 bar

- LA9D0

Séries

06 Series 1, index 0

Sentido de rotação2)

07 Visualizado no veio de transmissão sentido horário R
sentido anti-horário L

Material de selagem

08 FKM (fluoroelastómero) V

Veio de transmissão

09 Veio estriado

ANSI B92.1a

veio padrão - - - - S
semelhante ao veio "S", mas para binário de entrada mais elevado - - - - R

Flange de montagem

10 ISO 3019-1 (SAE) com 2 furos - - - - - C
com 4 furos - - - D

1) Please specify mechanical flow control VG Max e Vg min in the order text.

2)Changing direction of rotation permissible with the same pressure side for decompression

Porto de trabalho3)

003 to 010 018 028 045 071 100 140 180
11 SAE flange ports at top and bottom, on opposite sides, metric fastening thread with universal through drive - - - - 22U5)
SAE flange ports at top and bottom, on opposite sides, metric fastening thread - - 123)5)
DIN 3852 threaded ports at rear, not for through drive - - - - - - - 14
DIN 3852 threaded ports on opposite side, only for through drive - - - - - - - 07

Através da unidade de atendimento automóvel

003 to 010 018 028 045 071 100 140 180
12 With through-drive shaft, without hub, without intermediate flange;

fastening thread metric, with universal through drive, only port plate 22U

- - - - 004)5)
Without through drive, only port plates 12 and 14 N00
Port plate 12 and 07
Flange ISO 3019-1 Cubo para veio estriado6)

Diâmetro

Diâmetro Mounting7)
82-2 (A) 5/8in 9T 16/32DP - - - - K01
3/4 pol 11T 16/32DP - - - - K52
101-2(B) 7/8 in 13T 16/32DP - - - - - - K68
1 pol 15T 16/32DP - - - - - - - K04
Port plate 22U
Flange ISO 3019-1 Cubo para veio estriado6)

Diâmetro

Diâmetro
82-2 (A) 5/8 pol. 9T 16/32DP - - - - 01
3/4 pol 11T 16/32DP - - - - 52
101-2(B) 7/8 in 13T 16/32DP - - - - 68
1 pol 15T 16/32DP - - - - 04
1 1/4 pol 14T 12/24DP - - - - 06
127-4 (C) 1 pol 15T 16/32DP - - - - E2
1 1/4 pol 14T 12/24DP - - - - 15
152-4 (D) 1 1/2in 17T 12/24DP - - - - - 96
1 3/4in 13T 8/16DP - - - - - 17

Conetores para solenóides

13 without, with hydraulic controllers 0
HIRSCHMANN connector - without suppressor diode H

•= Available    ○ = On request     - = Not available

3)A stepless mechanical flow control is only standard on version 12 N00 in sizes 018 to 140

Vg máx: Setting range VG Max para 50% Vg máx sem degraus

Vg min: Please specify setting range Vg min to 40% VG Max stepless,settings to be specified in plain text.

Vg máx e Vg min limitations on through drives with port plates 12K..and 22U..can only be carried out via fixed set values, this should also be specified in plain text.

4)See data sheet 95581 universal through drive

5)When ordering sizes 071 to 180 with port plate 22, please order the relevant through drive "U"

Example: A10VZO045DR000/10R-VSD22U01

When ordering sizes 018 to 045 with port plate 12, please order the relevant through drive with "K"

Example: A10VZ0018DR000/10R-VSD12K01

6)Splined shaft according to ANSI B92.1a (splined shafts according to SAE J744)

7) Mounting holes pattern viewed on through drive with control at top

Technical data A10VZO size 3 to 45

Tamanho NG 3 6 8 10 18 28 45
Displacement, geometric,per revolution Vg máx cm3 3.5 6 8 10.5 18 28 45
Velocidade de rotação

máximo1)

at VG Max
Suction speed operation as a pump1) nnome rpm 3600 3600 3600 3600 3300 3000 3000
Max. speed decompression operation2) nnome rpm 3600 3600 3600 3600 3300 3000 3000
Fluxo at nnome e Vg max qv L/min 12.6 21.6 28.8 38 59 84 135
Energia

Operation as a pump

at nnome,Vg max

and Δp = 250 bar P kW 5 10 15 16 - - -
and Δp = 315 bar P kW - - - - 34 39 44
Torque at VG Max and Δp = 250 bar T Nm 14 24 32 42 - - -
at VG Max and Δp = 315 bar T Nm - - - - 90 140 225
at VG Max and Δp = 100 bar T Nm 6 9 13 17 29 140 225
Rotary stiffness of

drive shaft

S c Nm/rad 8100 8100 8100 8100 - - -
R c Nm/rad - - - - 14800 26300 41000
Moment of inertia for rotary group JTW Kgm2 0.0006 0.0006 0.0006 0.0006 0.00093 0.0017 0.0033
Maximum angular acceleration2)3) α rad/s2 14000 14000 14000 14000 12600 11200 9500
Case volume V L 0.2 0.2 0.2 0.2 0.25 0.3 1.0
Weight without through drive (14N00, 12N00 approx.) m kg 8 8 8 8 12 15 27
Weight without through drive (22U00 approx.) m kg - - - - - - -
Weight with through drive (07K.., 12K..approx.) m kg 10.5 10.5 10.5 10.5 14 18 28
Weight with through drive (22U..approx.) m kg - - - - - - -

Determining the operating characteristics

Fluxo qv=(Vg ∙ n ∙ ηv) / 1000 L/min
Torque M=(Vg ∙ Δp) / (20 ∙ π ∙ ηhm) Nm
Energia P=(2π ∙ M ∙ n)/60000=(qv ∙ Δp)/(600 ∙ ηt)  kW

Key

Vg  Displacement per revolution in [cm3]

Δp  Differential pressure [bar]

n   Rotational speed [rpm]

ηv   Volumetric efficiency

ηhm  Hydraulic-mechanical efficiency

ηt   Total efficiency (ηt= ηvhm)

1)The values are applicable:

- At absolute pressure Pabs = 1 bar at suction port S

- For the optimal viscosity range of vopt = 36 to 16 mm2/s

- For hydraulic fluid based on mineral oils

2)Higher values on request

3) The limit value is only valid for a single pump, multiple pump version available on request. The load capacity of the connecting parts must be considered.

Technical data A10VZO size 71 to 180

Tamanho NG 71 100 140 180
Displacement, geometric,per revolution Vg máx cm3 71.1 100 140 180
Velocidade de rotação

máximo1)

at VG Max
Suction speed operation as a pump1) nnome rpm 2550 2300 2200 1800
Max. speed decompression operation2) nnome rpm On request
Fluxo at nnome e Vg max qv L/min 181 230 308 324
Energia

Operation as a pump

at nnome,Vg max

and Δp = 280 bar

 

P

 

kW

 

84 107 143 151
Torque at VG Max and Δp = 280 bar T Nm 317 445 623 801
at VG Max and Δp = 100 bar T Nm 113 159 223 286
Rotary stiffness of

drive shaft

S c Nm/rad 8100 8100 8100 8100
R c Nm/rad - 121142 169537 171107
Moment of inertia for rotary group JTW Kgm2 0.0087 0.0185 0.0276 0.033
Maximum angular acceleration2)3) α rad/s2 7500 6200 5000 4000
Case volume V L 1.6 2.2 3.0 2.7
Weight without through drive (12N00, 42N00 approx.) m kg 36.5 55 70 -
Weight without through drive (22U00 approx.) m kg 47 69 73 78
Weight with through drive (12K..approx.) m kg - - - -
Weight with through drive (22U..approx.) m kg 47 69 73 78

Determining the operating characteristics

Fluxo qv=(Vg ∙ n ∙ ηv) / 1000 L/min
Torque T=(Vg ∙ Δp) / (20 ∙ π ∙ ηhm) Nm
Energia P=(2π ∙ T ∙ n)/60000=(qv ∙ Δp)/(600 ∙ ηt)  kW

Key

Vg  Displacement per revolution in [cm3]

Δp  Differential pressure [bar]

n   Rotational speed [rpm]

ηv   Volumetric efficiency

ηhm  Hydraulic-mechanical efficiency

ηt   Total efficiency (ηt= ηvhm)

1)The values are applicable:

- At absolute pressure Pabs = 1 bar at suction port S

- For the optimal viscosity range of vopt = 36 to 16 mm2/s

- For hydraulic fluid based on mineral oils

2)Higher values on request

3) The limit value is only valid for a single pump, multiple pump version available on request. The load capacity of the connecting parts must be considered.

4) With port plates 7 or 14

Permissible input and through-drive torques

Tamanho 003 to 10 18 28 45 71 100 140 180
Input torque
at drive shaft,
maximum2)
S TE max Nm 126 - - - - 1104 1620 1620
in 3/4 - - - - 1  1/2 1  3/4 1  3/4
R TE max Nm - 160 250 400 650 - - -
in - 3/4 7/8 1 1  1/4 - - -
Maximum through-
drive torque
S TD max Nm 41 - - - - 778 1266 1266
R TD max Nm - 92 127 229 480 - - -

Distribution of torques

Torque at 1st pump T1
Torque at 2nd pump T2
Torque at 3rd pump T3
Input torque TE=T1+T2+T3
TE < TE max
Through-drive torque TD=T2+T3
TD < TD max

1)Efficiency not considered

2) For drive shafts with no radial force

A10VZO