The 4WRAE proportional valve controls hydraulic direction and flow by direct actuation. The series table includes both WRA and WRAE versions; the WRAE integrated-electronics data must be used when matching the controller and connector.

  • Direct actuation
  • Spring-centered control spool
  • Integrated electronics for WRAE variant
  • Subplate mounting

PRANCE HYDRAULIC · PRODUCT SERIES

cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits

Direct-operated proportional directional valve · Subplate-mounted direction and flow control

The 4WRAE proportional valve controls hydraulic direction and flow by direct actuation. The series table includes both WRA and WRAE versions; the WRAE integrated-electronics data must be used when matching the controller and connector.

Model

✓cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits
4WRAEDirect-operated proportional directional valve
Request a QuotationVer Datos Técnicos y Ficha Técnica

Confirm the complete model and approved specification with Prance Hydraulic. Product-series references alone do not establish interchangeability.

Configuration review · Technical documentation · Product selection

Detalles del producto

  • Direct actuation
  • Spring-centered control spool
  • Integrated electronics for WRAE variant
  • Subplate mounting

CATEGORIES: Válvula hidráulica, Válvula proporcional

4WRAE Features & Application

Direct actuation

Specify the full MS order code, installation drawing and operating duty so the quotation can identify the proposed configuration.

Spring-centered control spool

Match the complete control option and its command requirements to the existing controller. Similar housings can use different control arrangements.

Integrated electronics for WRAE variant

Match the complete control option and its command requirements to the existing controller. Similar housings can use different control arrangements.

Subplate mounting

Check pilot diameter, bolt pattern, shaft engagement or port pattern against the approved installation drawing.

4WRAE Specifications

Series / model4WRAE
Product typecURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits
DiseñoDirect-operated proportional directional valve
Circuit / selectionSubplate-mounted direction and flow control
Published nominal sizes6 and 10
Listed WRAE command variantsA1: ±10 V; F1: 4–20 mA
Rated-flow test conditionΔp = 10 bar in the existing technical table

4WRAE Selection & Configuration

The 4WRAE proportional valve controls hydraulic direction and flow by direct actuation. The series table includes both WRA and WRAE versions; the WRAE integrated-electronics data must be used when matching the controller and connector.

Confirm nominal size, spool characteristic and command input before choosing a rated flow. Rated flow is given at a specified pressure drop and is different from maximum permissible flow. Keep the WRA and WRAE electrical data separate during comparison.

4WRAE original product view

cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits.
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits.

Hydraulic pumps · Hydraulic motors · Hydraulic valves

Send the MS nameplate, operating requirements and installation drawing for a configuration review before quoting.

  • Model review — send the full model code or an existing nameplate photograph.
  • Interface matching — confirm shaft, mounting flange, rotation and ports.
  • Operating conditions — provide flow, pressure, speed, fluid and duty cycle.
  • Documentation — request the relevant product data and drawings for your review.
Prance workshop with a row of production equipment

4WRAE Buying Guide

Use this sequence to prepare the 4WRAE configuration for review and quotation.

  1. Select the circuit symbol and required de-energized spool position.
  2. State working flow, pressure and the pressure-drop condition for rated flow.
  3. Review spool overlap and command behavior during startup and switch-off.
  4. Confirm nominal size, subplate pattern, port and seal requirements.
  5. Match supply voltage, command input, connector and pin assignment.
  6. Review pilot supply, drain and feedback where the selected valve uses them.
  7. Approve the exact valve code, circuit drawing, quantity and documentation.
4WRAE original product photograph for installation review

Selection, Documentation & Project Support

Prance technical team image from its company website

Selection Support

Learn more →

Share your hydraulic circuit, operating point and installation requirements for a configuration discussion.


Flow · Pressure · Speed · Interfaces
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits

Technical Resources

Learn more →

Review product documentation, model codes and technical data before finalizing the specification.


Datasheets · Model codes · Drawings
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits

Project Inquiries

Learn more →

Send your required model, quantity, application and project requirements to discuss your inquiry.


Product inquiries · Configuration review

Configuration, Quantity & Delivery

Confirm the complete MS code, approved drawing and operating limits. Availability, quantity, documentation and delivery date are confirmed in the quotation.

Discuss Your 4WRAE Application

Send the full model code, operating duty, installation details and quantity.

Request a 4WRAE Quotation

4WRAE Questions Before Ordering

What type of product is the 4WRAE?

4WRAE Direct Operated Proportional Valve. Design: Direct-operated proportional directional valve. Subplate-mounted direction and flow control. Confirm the complete order code for the offered version.

Can a similar valve replace the 4WRAE?

cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits.

cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits

Select the circuit symbol and required de-energized spool position. State working flow, pressure and the pressure-drop condition for rated flow. Attach the nameplate, complete order code, installation drawing and required quantity.

4WRAE Technical Data & Documents

View 4WRAE catalog data and operating conditions

cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits.

Datos técnicos

(para aplicaciones fuera de estos parámetros, ¡consúltenos!)

General

Tamaño nominal NS 6 10
Instalación opcional, preferiblemente horizontal
Rango de temperatura de almacenamiento ℃ -20 a +80
Ambiente 4WRA ℃ -20 a +70
rango de temperatura 4WRAE ℃ -20 a +50
Peso 4WRA kg 2.0 6.6
4WRAE kg 2.2 6.8
Hidráulico (medido con HLP46, Θaceite= 40 ℃±5 ℃)
Presión máx. de servicio Puertos A, B, P bar 315
Puerto T bar 210
Caudal nominal qV nom a Δp=10 bar l/min 7,15,26 30,60
Flujo máximo permisible l/min 42 (80)1) 75 (140)1)
Fluido a presión mineral oil (HL, HLP) to DIN 51524 other pressure fluids on request!
Rango de temperatura del fluido a presión ℃ -20 a +80 (preferiblemente de +40 a +50)
Rango de viscosidad mm2/s 20 a 380 (preferiblemente 30 a 46)
Grado máximo admisible de contaminación del fluido a presión, clase de limpieza según ISO 4406 (c) clase 20/18/15 2)
Histéresis % ≤ 5
Error de inversión % ≤ 1
Sensibilidad de respuesta % ≤ 0.5
1)permissible flow with a dual flow path 2)The cleanliness class stated for the components must be adhered too in hydraulic systems. Effective filtration prevents faults from occurring and at the same time increases the component service life.For the selection of filters see catalogue sheets RE 50070,RE 50076, RE 50081, RE 50086 and RE 50088

Eléctrico

Tamaño nominal NS 6 10
Tipo de voltaje DC
Valor del comando signa Voltage input “A1” V ±10
con tipo WRAE Current input “F1” mA 4 a 20
Corriente máx. por solenoide A 2.5
Bobina de solenoide Valor en frío a 20 ℃ Ω 2
resistencia Valor máximo de calor Ω 3
Deber % 100
Temperatura máx. de la bobina 1) ℃ 150
Electrical connections see page 7 4WRA con conector de enchufe según DIN EN 175301-803 o ISO 4400
conector enchufable según DIN EN 175301-803 o ISO 4400 2)
4WRAE con conector según DIN EN 175201-804
conector enchufable DIN EN 175201-804 2)
Protección de válvula según EN 60529 IP65 con conector enchufable montado y fijo

Electrónica de control

Para 4WRA Amplificador digital en formato Eurocard 2) VT-VSPD-1-2X (to RE 30523 – middle of 2006)
Amplificador analógico en formato Eurocard 2) VT-VSPA2-1-2X/… to RE 30110
Amplificador de módulo analógico 2) VT-MSPA2-1-1X a RE 30228
Para 4WRAE Módulo de valor de consigna analógico integrado en las válvulas, ver página 8
VT- SWMA-1-1X/… to RE 29902
Módulo de valor de consigna analógico VT-SWMKA-1-1X/… to RE 29903
tarjeta de valor de mando digital VT-HACD-1-1X/… to RE 30143
Tarjeta de valor de mando analógico VT-SWKA-1-1X/… to RE 30255
Supply voltage 4WRAE, 4WRA 3) Tensión nominal VDC 24
Valor límite inferior V 21 / 22 (4WRA); 19 (4WRAE)
Valor límite superior V 35
Corriente del amplificador lmáx A 1.8
consumo Corriente de impulso máx. A 3
1) Due to the occurring surface temperature of the solenoid coils, the European Standards DIN EN 563 and DIN EN 982must be taken into account! 2) Separate order 3) With Bosch Rexroth AG control electronics

Nota:

Para obtener detalles sobre la prueba de simulación ambiental que abarca EMC (compatibilidad electromagnética), clima y carga mecánica, consulte RE 29055-U (declaración relativa a la compatibilidad ambiental).
Watch 4WRAE Product Video
4WRAE product video

Request a 4WRAE Quotation

Tell us your required configuration, quantity and application.

Demostración de formulario de contacto
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits

Datos técnicos

(para aplicaciones fuera de estos parámetros, ¡consúltenos!)

General

Tamaño nominal NS 6 10
Instalación opcional, preferiblemente horizontal
Rango de temperatura de almacenamiento ℃ -20 a +80
Ambiente 4WRA ℃ -20 a +70
rango de temperatura 4WRAE ℃ -20 a +50
Peso 4WRA kg 2.0 6.6
4WRAE kg 2.2 6.8
Hidráulico (medido con HLP46, Θaceite= 40 ℃±5 ℃)
Presión máx. de servicio Puertos A, B, P bar 315
Puerto T bar 210
Caudal nominal qV nom a Δp=10 bar l/min 7,15,26 30,60
Flujo máximo permisible l/min 42 (80)1) 75 (140)1)
Fluido a presión aceite mineral (HL, HLP) según DIN 51524
¡Otros fluidos a presión bajo petición!
Rango de temperatura del fluido a presión ℃ -20 a +80 (preferiblemente de +40 a +50)
Rango de viscosidad mm2/s 20 a 380 (preferiblemente 30 a 46)
Grado máximo admisible de contaminación del fluido a presión, clase de limpieza según ISO 4406 (c) clase 20/18/15 2)
Histéresis % ≤ 5
Error de inversión % ≤ 1
Sensibilidad de respuesta % ≤ 0.5

1) caudal permisible con una ruta de flujo dual

2) En los sistemas hidráulicos se debe respetar la clase de limpieza especificada para los componentes. Una filtración eficaz evita que se produzcan fallos y al mismo tiempo aumenta la vida útil de los componentes. Para la selección de filtros, véanse las hojas de catálogo RE 50070, RE 50076, RE 50081, RE 50086 y RE 50088.

Eléctrico

Tamaño nominal NS 6 10
Tipo de voltaje DC
Valor del comando signa Entrada de voltaje "A1" V ±10
con tipo WRAE F1" mA 4 a 20
Corriente máx. por solenoide A 2.5
Bobina de solenoide Valor en frío a 20 ℃ Ω 2
resistencia Valor máximo de calor Ω 3
Deber % 100
Temperatura máx. de la bobina 1) ℃ 150
Conexiones eléctricas
ver página 7
4WRA con conector de enchufe según DIN EN 175301-803 o ISO 4400
conector enchufable según DIN EN 175301-803 o ISO 4400 2)
4WRAE con conector según DIN EN 175201-804
conector enchufable DIN EN 175201-804 2)
Protección de válvula según EN 60529 IP65 con conector enchufable montado y fijo

Electrónica de control

Para 4WRA Amplificador digital en formato Eurocard 2) VT-VSPD-1-2X (hasta RE 30523 - mediados de 2006)
Amplificador analógico en formato Eurocard 2) VT-VSPA2-1-2X/... a RE 30110
Amplificador de módulo analógico 2) VT-MSPA2-1-1X a RE 30228
Para 4WRAE Módulo de valor de consigna analógico integrado en las válvulas, ver página 8
VT- SWMA-1-1X/... a RE 29902
Módulo de valor de consigna analógico VT-SWMKA-1-1X/... a RE 29903
tarjeta de valor de mando digital VT-HACD-1-1X/... a RE 30143
Tarjeta de valor de mando analógico VT-SWKA-1-1X/... a RE 30255
Tensión de alimentación
4WRAE, 4WRA 3)
Tensión nominal VDC 24
Valor límite inferior V 21 / 22 (4WRA);
19 (4WRAE)
Valor límite superior V 35
Corriente del amplificador lmáx A 1.8
consumo Corriente de impulso máx. A 3

1) ¡Debido a la temperatura superficial de las bobinas del solenoide que se produce, se deben tener en cuenta las normas europeas DIN EN 563 y DIN EN 982!

2) Pedido separado

3) Con electrónica de control de Bosch Rexroth AG

Nota:

Para obtener detalles sobre la prueba de simulación ambiental que abarca EMC (compatibilidad electromagnética), clima y carga mecánica, consulte RE 29055-U (declaración relativa a la compatibilidad ambiental).

4WRAE