The A10VM variable displacement motor allows the torque-speed relationship to be changed through displacement. At the same flow, reducing displacement increases theoretical speed; at the same pressure difference it also reduces theoretical torque.
- Variable displacement A10 motor
- Output speed depends on flow and displacement
- Torque depends on pressure difference and displacement
- SAE two-bolt mounting reference
PRANCE HYDRAULIC · PRODUCT SERIES
Axial piston; swashplate variable displacement · Confirm open or closed circuit conditions
The A10VM variable displacement motor allows the torque-speed relationship to be changed through displacement. At the same flow, reducing displacement increases theoretical speed; at the same pressure difference it also reduces theoretical torque.
Model

Confirm the complete model and approved specification with Prance Hydraulic. Product-series references alone do not establish interchangeability.
Configuration review · Technical documentation · Product selection
Detalhes do Produto
- Variable displacement A10 motor
- Output speed depends on flow and displacement
- Torque depends on pressure difference and displacement
- SAE two-bolt mounting reference
CATEGORIES: Motor de pistões, Motor de pistões de cilindrada variável
A10VM Features & Application
Variable displacement A10 motor
Specify the displacement range or switching arrangement and verify performance at each required setting.
Output speed depends on flow and displacement
Keep continuous, intermittent and peak conditions separate. Use the row for the selected size and configuration.
Torque depends on pressure difference and displacement
Keep continuous, intermittent and peak conditions separate. Use the row for the selected size and configuration.
SAE two-bolt mounting reference
Check pilot diameter, bolt pattern, shaft engagement or port pattern against the approved installation drawing.
A10VM Specifications
| Series / model | A10VM |
|---|---|
| Product type | cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits |
| Design | Axial piston; swashplate variable displacement |
| Circuit / selection | Confirm open or closed circuit conditions |
| Controlo de deslocamento | Variable |
| Mounting reference | SAE two-bolt flange in the existing description |
A10VM Selection & Configuration
The A10VM variable displacement motor allows the torque-speed relationship to be changed through displacement. At the same flow, reducing displacement increases theoretical speed; at the same pressure difference it also reduces theoretical torque.
Define the required displacement range and its control behavior before selecting the motor. Check the highest commanded speed and the torque available at minimum displacement, then match the SAE flange, shaft, ports and drain arrangement to the installation.

cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits.
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits.
Hydraulic pumps · Hydraulic motors · Hydraulic valves
Send the MS nameplate, operating requirements and installation drawing for a configuration review before quoting.
- Model review — send the full model code or an existing nameplate photograph.
- Interface matching — confirm shaft, mounting flange, rotation and ports.
- Operating conditions — provide flow, pressure, speed, fluid and duty cycle.
- Documentation — request the relevant product data and drawings for your review.

A10VM Buying Guide
Use this sequence to prepare the A10VM configuration for review and quotation.
- Define starting and continuous torque, speed range and duty cycle.
- Specify available flow, work-port pressure difference and return pressure.
- Confirm the displacement setting and required behavior during starting and stopping.
- Check shaft, mounting pilot, flange, port orientation and external loads.
- Review case drainage, replenishment and any displacement control.
- Specify fluid conditions and any independent braking requirement.
- Approve the complete model, operating envelope, drawing and quantity.

Selection, Documentation & Project Support

Selection Support
Learn more →Share your hydraulic circuit, operating point and installation requirements for a configuration discussion.
Flow · Pressure · Speed · Interfaces

Technical Resources
Learn more →Review product documentation, model codes and technical data before finalizing the specification.
Datasheets · Model codes · Drawings

Project Inquiries
Learn more →Send your required model, quantity, application and project requirements to discuss your inquiry.
Product inquiries · Configuration review
Configuration, Quantity & Delivery
Confirm the complete MS code, approved drawing and operating limits. Availability, quantity, documentation and delivery date are confirmed in the quotation.
Discuss Your A10VM Application
Send the full model code, operating duty, installation details and quantity.
Request a A10VM QuotationA10VM Questions Before Ordering
What type of product is the A10VM?
A10VM Variable Displacement Axial Piston Motor. Design: Axial piston; swashplate variable displacement. Confirm open or closed circuit conditions. Confirm the complete order code for the offered version.
Can a similar motor replace the A10VM?
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits.
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits.
A10VM Technical Data & Documents
View A10VM catalog data and operating conditions
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits.
Dados técnicos
Fluido
Antes de proceder ao projeto, consulte as nossas fichas de dados RE 90220 (óleo mineral), RE 90221 (ecologically acceptable fluids) and RE90223(HF-fluids) for detailed information on fluids and application conditions. When operating on ecologically acceptable fluids, limitations to the technical data may be necessary. Please contact us and state the fluid used in clear text when ordering.Gama de viscosidade de funcionamento
For optimum efficiency and service life we recommend an ope-rating viscosity (at operating temperature) in the range νoptar = opt. operating viscosity 16…36 mm2/s referred to circuit temperature in closed circuits or tank temperature in open circuits. The following limits are valid for extreme operating conditions: Vmin=5 mm2/s (closed circuit) Vmin=10 mm2/s (open circuit) briefly (t≤ 1 min) at max. permissible temperature of 115℃. Please note, that the max. fluid temperature of 115℃ may also not be exceeded in certain areas (for instance bearing area) The temperature in the bearing area is approx. 5 K higher than the average fluid temperature. νmáx=1600 mm2/s briefly (t≤ 1 min) on cold start (tmin = -25℃, p≤30 bar, n≤1000 rpm). At temperatures between -25 ℃ and -40 ℃ special measures may be required for certain installation positions. Please consult us for further information For detailed information on operation at very low temperatures see RE 90300-03-B.Notas sobre a seleção do fluido hidráulico
In order to select the correct fluid, it is necessary to know the operating temperature in the tank (open circuit), circuit temperature (closed circuits), in relation to the ambient temperature. The fluid should be selected, so that within the operating temperature range, the viscosity lies within the optimum range(νoptar), see shaded section of the selection diagram. We recommend to select the higher viscosity grade in each case. Example: at an ambient temperature of X ℃ the operating temperature in the tank is 60℃.In the optimum viscosity range(νoptar; shaded area) this corresponds to viscosity grades VG 46 resp. VG 68; select VG 68. Important: The leakage fluid (case drain fluid) temperature is influenced by pressure and motor speed and is always higher than the tank temperature. However, at no point in the circuit may the temperature exceed 115 ℃. If it is not possible to comply with the above conditions because of extreme operating parameters or high ambient temperatures please consult usFiltração de fluidos
The finer the filtration the better the achieved cleanliness of the fluid and the longer the life of the axial piston unit. To ensure a reliable functioning of the axial piston unit, a minimum cleanliness of 20/18/15 to ISO 4406 is necessary. At very high fluid temperatures (90℃ to max. 115℃) the minimum cleanliness has to be at least 19/17/14 to ISO 4406. If above cleanliness classes cannot be met please consult us.Gama de pressão de funcionamento
Pressure at port A or B (Pressure data to DIN 24312)| Pressão nominal pN | 280 bar 1) |
| Pressão máxima Pmáx | 350 bar |
| No caso de motores ligados em série, por favor consulte-nos. | |
| Pressão máx. admissível na porta de fuga L | |
| Pabs operação máxima como motor em circuito aberto | abdómen de 4 placas |
| Pabs operação máxima como motor em circuito fechado | abdómen de 4 placas |
| Pabs operação máxima do motor/bomba em circuito aberto | 2 bar abs |
| Sentido de rotação, visto na extremidade do eixo | |||||
| sentido horário | sentido anti-horário | ||||
| B para A | De A a B | ||||
Diagrama de seleção
Tabela de valores(valores teóricos, sem níveis de eficiência e tolerâncias; valores arredondados)
| Tamanho | 28 | 45 | 63 | 85 | |||
| Deslocamento | VG Max | cm3 | 28 | 45 | 62 | 87 | |
| Vg min | cm3 | 8 (VM)/10(VE) | 12 | 16 | 22 | ||
| Velocidade1) | 4700 | 4000 | 3300 | 3100 | |||
| máx. a VG Max | n0 máximo | min-1 | |||||
| máx. a Vg min | n0 máx zul | min-1 | 5400 | 4600 | 3900 | 3560 | |
| Vel. mín. em func. cont. | n0 min | min-1 | 250 | 250 | 250 | 250 | |
| Caudal de entrada | 131,6 | 180 | 205 | 270 | |||
| Beijinho0 máximo e VG Max | qv0 máx | L/min | |||||
| Constante de binário2) às VG Max | TK | Nm/bar | 0,445 | 0,716 | 1,002 | 1,35 | |
| Binário | 125 | 200 | 276 | 387 | |||
| às VG Max | PN= 280 bar | Tmáx | Nm | ||||
| Binário de arranque efetivo | 92 | 149 | 205 | 253 | |||
| em n=0 min-1 | PN = 280 bar | T | Nm ca. | ||||
| Rigidez torcional | Eixo R | c | Nm/rad | 26000 | 41000 | 69400 | 152900 |
| Veio W | c | Nm/rad | 19800 | 34400 | 54000 | 117900 | |
| Momento de inércia de massa (em relação ao veio de saída) | J | kgm2 | 0,0017 | 0,0033 | 0,0056 | 0,012 | |
| Volume de enchimento | V | L | 0,6 | 0,7 | 0,8 | 1,0 | |
| Peso aprox. | m | kg | 14 | 18 | 26 | 34 | |
dependendo da velocidade do motor
A calcular o tamanho
| Fluxo | qv=(Vg∙n)/(1000∙ηv) | [L/min] | Vg=Cilindrada por rotação em cm³3 Δp=Differential pressure in bar n=speed in rpm ηv=Volumetric efficiency ηmh=Mechanical-hydraulic efficiency ηt= Eficiência total (ηt = ηv ∙ηmh) TK=Constante de binário |
| Binário | T=(1,59∙Vg∙ Δp∙ηmh)/100 | [Nm] | |
| ou | T=Tk∙ Δp∙ηmh | ||
| Potência de saída | P=(2π∙T∙n)/60000=(qv∙Δp∙ηt)/600 | [kW] | |
| Velocidade de saída | n=(qv∙1000∙ηv)/Vg | [min-1] | |
Forças radiais e axiais admissíveis no eixo de acionamento
| Tamanho | 28 | 45 | 63 | 85 | ||||
| Força radial máx. | ![]() |
a X/2 | Fque máximo | N | 1200 | 1500 | 1700 | 2000 |
| Força axial máx. | ![]() |
Fmachado | N | 1000 | 1500 | 2000 | 3000 | |
Watch A10VM Product Video
Related Selection Resources
Request a A10VM Quotation
Tell us your required configuration, quantity and application.
Código de encomenda para o programa padrão
| A10V | M | / | 52 | W | – | V | C | ||||||||
| 01 | 02 | 03 | 04 | 05 | 06 | 07 | 08 | 09 | 10 | 11 | 12 | 13 | 14 |
Unidade de pistões axiais
| 01 | Conceito de prato oscilante, variável, pressão nominal 280 bar, pressão máxima 350 bar | A10V |
Modo de Funcionamento
| 02 | Motor, circuito aberto e fechado | M |
Tamanho (NG)
| 03 | CilindradaG Max em cm3 | 028 | 045 | 063 | 085 |
Dispositivos de controlo
| 028 | 045 | 063 | 085 | ||||||
| 04 | Dois ponto controlo |
Operado diretamente, alimentação de controlo externo, sem válvula piloto | ● | ● | ● | ● | DG | ||
| Acionado hidraulicamente | Tempo de festas | sem | ● | ● | ● | ○ | Hz | ||
| Eletricamente com válvula solenoide | orifício | com | ● | ● | ● | ○ | HZ6 | ||
| Eletricamente com válvula solenoide | Tempo de festas | sem | ● | ● | ● | ● | EZ1 | ||
| tensão de controlo 12V | orifício | com | ● | ● | ● | ● | EZ6 | ||
| Eletricamente com válvula solenoide | Tempo de festas | sem | ● | ● | ● | ○ | EZ2 | ||
| tensão de controlo 24V | orifício | com | ● | ● | ● | ○ | EZ7 | ||
Séries
| 05 | Série 5, Índice 2 | 52 |
Sentido de rotação
| 06 | Visto do lado da extremidade do veio Bidirecional | W |
Deslocamento mínimo
| 028 | 045 | 063 | 085 | ||||
| 07 | Vg min (em cm3) com regulação contínua | de/para | 8/28 | 12/25 | 16/38 | 22/50 | 1 |
| Estado de ajuste em texto simples | de/para | – | 26/45 | 40/62 | 48/85 | 2 | |
Focas
| 08 | FKM (boracha fluorada) | V |
Veio de transmissão
| 028 | 045 | 063 | 085 | |||
| 09 | Veio ranhurado, ANSI B92.1 a-1976, para maior binário de transmissão | ● | ● | ● | ● | R |
| Eixo estriado, ANSI B92.1 a-1976, para binário de acionamento reduzido | – | ● | ● | ● | W | |
Flange de montagem
| 10 | SAE J744 de 2 furos | C |
Portos para linhas de serviço
| 11 | Flanges SAE, do mesmo lado-mesmo lado, parafusos de fixação métricos | ● | ● | ● | ● | 10N00 | |||||
| Flanges SAE na parte posterior, parafusos de fixação métricos | ○ | ● | ○ | ○ | 11N00 | ||||||
| Orifícios roscados na lateral, no mesmo lado, rosca métrica | ● | ● | ● | ○ | 16N00 | ||||||
Válvulas
| 12 | Sem válvulas | ● | ● | ● | ● | 0 | |||||
| Válvula de lavagem integrada, apenas com pórticos laterais (10N00 e 16N00) | ● | ● | ● | ● | 7 | ||||||
Aceleração
| 13 | Sem captação de velocidade | ● | ● | ● | ● | – | ||||
| Preparado para captador de velocidade de tipo indutivo ID R | ● | ● | ● | ○ | D | |||||
Conector para solenóides
| 14 | conetor HIRSCHMANN — sem díodo suppressor | ▲ | ▲ | ▲ | ▲ | H | |||||
| conetor DEUTSCH, moldado, de 2 pinos — sem díodo supressor | ● | ● | ● | ● | P | ||||||
•=disponível ○=em preparação — =indisponível ▲=não aplicável a novos projetos
| A10V | E | / | 52 | W | – | V | F | ||||||||
| 01 | 02 | 03 | 04 | 05 | 06 | 07 | 08 | 09 | 10 | 11 | 12 | 13 | 14 |
Unidade de pistões axiais
| 01 | Conceito de prato oscilante, variável, pressão nominal 280 bar, pressão máxima 350 bar | A10v | |||||||
Modo de funcionamento
| 02 | Motor, do tipo de ficha, circuito aberto e fechado | E | |||
Tamanho (NG)
| 03 | CilindradaG Max em cm3 | 028 | 045 | 063 |
Dispositivos de controlo
| 028 | 045 | 063 | ||||||
| 04 | Dois ponto controlo |
Operado diretamente, alimentação de controlo externo, sem válvula piloto | ● | ● | ○ | DG | ||
| Hidraulicamente | Tempo de festas | sem | ● | ● | ● | Hz | ||
| orifício | com | ● | ● | ● | HZ6 | |||
| Eletricamente com válvula solenoide | Tempo de festas | sem | ● | ● | ● | EZ1 | ||
| tensão de controlo 12V | orifício | com | ● | ● | ● | EZ6 | ||
| Eletricamente com válvula solenoide | Tempo de festas | sem | ● | ● | ● | EZ2 | ||
| tensão de controlo 24V | orifício | com | ● | ● | ● | EZ7 | ||
Séries
| 05 | Série 5, Índice 2 | 52 |
Sentido de rotação
| 06 | Visualização na extremidade do eixo Bidirecional | W | ||||
Deslocamento mínimo
| 028 | 045 | 063 | ||||
| 07 | Vg min (em cm3agulhas ajustáveis | de/para | 10/28 | 12/25 | 16/38 | 1 |
| Ajuste, por favor indique claramente | de/para | – | 26/45 | 40/62 | 2 | |
Focas
| 08 | FKM (boracha fluorada) | V |
Veio de transmissão
| 028 | 045 | 063 | |||||||
| 09 | Veio ranhurado, ANSI B92.1 a-1976, para maior binário de transmissão | ● | ● | ● | R | ||||
| Eixo estriado, ANSI B92.1 a-1976, para binário de acionamento reduzido | – | ● | ● | W | |||||
Flange de montagem
| 10 | Especial de 2 pernos | F |
Portas para a linha de serviço
| 11 | Flanges SAE do mesmo lado, parafusos de fixação métricos | ● | ● | ● | 10N00 | ||||
| Flanges SAE na parte posterior, parafusos de fixação métricos | ○ | ● | ○ | 11N00 | |||||
| Orifícios roscados na lateral, no mesmo lado, rosca métrica | ● | ● | ● | 16N00 | |||||
Válvulas
| 12 | Sem válvulas | ● | ● | ● | 0 | |||||
| Válvula de lavagem integrada, apenas com pórticos laterais (10N00 e 16N00) | ● | ● | ● | 7 | ||||||
Aceleração
| 13 | Sem captação de velocidade | ● | ● | ● | – | ||||
| Preparado para captador de velocidade de tipo indutivo ID R | ○ | ● | ○ | D | |||||
Conector para solenóides
| 14 | HIRSCHMANN - conector—sem díodo de supressão | ▲ | ▲ | ▲ | H | |||||
| DEUTSCH - conetor, moldado, de 2 pinos—sem díodo de supressão | ● | ● | ● | P | ||||||
•=disponível ○=em preparação — =indisponível ▲=não aplicável a novos projetos
Dados técnicos
Fluido
Antes de proceder ao projeto, consulte as nossas fichas de dados RE 90220 (óleo mineral), RE 90221 (fluidos ecologicamente aceitáveis) e RE90223(fluidos HF) para informação detalhada sobre fluidos e condições de aplicação.
Ao trabalhar com fluidos ecologicamente aceitáveis, podem ser necessárias limitações aos dados técnicos.
Por favor, contacte-nos e indique o fluido utilizado em texto claro ao efetuar a encomenda.
Gama de viscosidade de funcionamento
Para otimizar a eficiência e a vida útil, recomendamos uma viscosidade de funcionamento (à temperatura de funcionamento) no intervalo
νoptar = viscosidade de funcionamento ót. 16...36 mm2/s
referido à temperatura do circuito em circuitos fechados ou à temperatura do depósito em circuitos abertos.
Os seguintes limites são válidos para condições de funcionamento extremas:
Vmin=5 mm2/s (circuito fechado)
Vmin=10 mm2/s (circuito aberto)
brevemente (t ≤ 1 min) à temperatura máx. admissível de 115℃.
Note-se que a temperatura máxima do fluido de 115 °C também não pode ser excedida em certas áreas (por exemplo, na área dos chumaceiros)
A temperatura na zona do rolamento é aprox. 5 K superior à temperatura média do fluido.
νmáx=1600 mm2/s
brevemente (t ≤ 1 min)
no arranque a frio (tmin = -25℃, p≤30 bar, n≤1000 rpm).
A temperaturas entre -25 ℃ e -40 ℃, podem ser necessárias medidas especiais para determinadas posições de montagem. Por favor, consulte-nos para mais informações.
Para informações detalhadas sobre o funcionamento a temperaturas muito baixas, consulte RE 90300-03-B.
Notas sobre a seleção do fluido hidráulico
Para selecionar o fluido correto, é necessário conhecer a temperatura de funcionamento no depósito (circuito aberto) ou a temperatura do circuito (circuitos fechados), em relação à temperatura ambiente.
O fluido deve ser selecionado de modo que, dentro da gama de temperatura de funcionamento, a viscosidade se situe na gama ideal (νoptar), ver a secção a sombreado no diagrama de seleção. Recomendamos selecionar sempre o grau de viscosidade mais elevado em cada caso.
Exemplo: a uma temperatura ambiente de X ℃, a temperatura de funcionamento no tanque é de 60 ℃. Na gama de viscosidade ideal (νoptar; área sombreada) isto corresponde aos graus de viscosidade VG 46 resp. VG 68; selecionar VG 68.
Importante: A temperatura do fluido de fuga (fluido de drenagem da caixa) é influenciada pela pressão e pela velocidade do motor e é sempre superior à temperatura do depósito. Contudo, em nenhum ponto do circuito a temperatura pode exceder 115 ℃.
Se não for possível cumprir as condições acima devido a parâmetros de funcionamento extremos ou a temperaturas ambiente elevadas, por favor consulte-nos
Filtração de fluidos
Quanto mais fina for a filtração, melhor será o nível de limpeza do fluido alcançado e maior será a vida útil da unidade de pistões axiais.
Para garantir um funcionamento fiável da unidade de pistões axiais, é necessária uma limpeza mínima de
É necessária a conversão de 20/18/15 para a norma ISO 4406.
A temperaturas de fluidos muito elevadas (90℃ a máx. 115℃), o nível de limpeza mínimo tem de ser de pelo menos
19/17/14 para ISO 4406.
Se as classes de limpeza acima não puderem ser cumpridas, por favor consulte-nos.
Gama de pressão de funcionamento
Pressão na porta A ou B
(Dados de pressão conforme a norma DIN 24312)
| Pressão nominal pN | 280 bar 1) |
| Pressão máxima Pmáx | 350 bar |
| No caso de motores ligados em série, por favor consulte-nos. | |
pressão de dreno da caixa
| Pressão máx. admissível na porta de fuga L | |
| Pabs operação máxima como motor em circuito aberto | abdómen de 4 placas |
| Pabs operação máxima como motor em circuito fechado | abdómen de 4 placas |
| Pabs operação máxima do motor/bomba em circuito aberto | 2 bar abs |
Sentido de rotação
| Sentido de rotação, visto na extremidade do eixo | |||||
| sentido horário | sentido anti-horário | ||||
| B para A | De A a B | ||||
Ajuste de deslocamento
O deslocamento mínimo é regulável de forma contínua dentro do intervalo dos comprimentos dos parafusos
1 ou 2 (ver código de encomenda).
Indique o deslocamento mínimo em texto claro ao encomendar.
Diagrama de seleção

Tabela de valores(valores teóricos, sem níveis de eficiência e tolerâncias; valores arredondados)
| Tamanho | 28 | 45 | 63 | 85 | |||
| Deslocamento | VG Max | cm3 | 28 | 45 | 62 | 87 | |
| Vg min | cm3 | 8 (VM)/10(VE) | 12 | 16 | 22 | ||
| Velocidade1) | 4700 | 4000 | 3300 | 3100 | |||
| máx. a VG Max | n0 máximo | min-1 | |||||
| máx. a Vg min | n0 máx zul | min-1 | 5400 | 4600 | 3900 | 3560 | |
| Vel. mín. em func. cont. | n0 min | min-1 | 250 | 250 | 250 | 250 | |
| Caudal de entrada | 131,6 | 180 | 205 | 270 | |||
| Beijinho0 máximo e VG Max | qv0 máx | L/min | |||||
| Constante de binário2) às VG Max | TK | Nm/bar | 0,445 | 0,716 | 1,002 | 1,35 | |
| Binário | 125 | 200 | 276 | 387 | |||
| às VG Max | PN= 280 bar | Tmáx | Nm | ||||
| Binário de arranque efetivo | 92 | 149 | 205 | 253 | |||
| em n=0 min-1 | PN = 280 bar | T | Nm ca. | ||||
| Rigidez torcional | Eixo R | c | Nm/rad | 26000 | 41000 | 69400 | 152900 |
| Veio W | c | Nm/rad | 19800 | 34400 | 54000 | 117900 | |
| Momento de inércia de massa (em relação ao veio de saída) | J | kgm2 | 0,0017 | 0,0033 | 0,0056 | 0,012 | |
| Volume de enchimento | V | L | 0,6 | 0,7 | 0,8 | 1,0 | |
| Peso aprox. | m | kg | 14 | 18 | 26 | 34 | |
1) À velocidade máxima em funcionamento em circuito fechado, certifique-se de que a pressão na saída do motor é de pelo menos ≥ 18 bar.
2) Em circuito aberto Δp 280bar em Pboostpress. 2bar
Em circuito fechado Δp 260bar em Pboostpress. 20 bar
Pressão de saída mínima necessária (baixa pressão) na porta A (B)
dependendo da velocidade do motor

A calcular o tamanho
| Fluxo | qv=(Vg∙n)/(1000∙ηv) | [L/min] | Vg=Cilindrada por rotação em cm³3 Δp=Pressão diferencial em bar n=velocidade em rpm ηv=Eficiência volumétrica ηmhEficiência mecânico-hidráulica ηt= Eficiência total (ηt = ηv ∙ηmh) TK=Constante de binário |
| Binário | T=(1,59∙Vg∙ Δp∙ηmh)/100 | [Nm] | |
| ou | T=Tk∙ Δp∙ηmh | ||
| Potência de saída | P=(2π∙T∙n)/60000=(qv∙Δp∙ηt)/600 | [kW] | |
| Velocidade de saída | n=(qv∙1000∙ηv)/Vg | [min-1] | |
Forças radiais e axiais admissíveis no eixo de acionamento
| Tamanho | 28 | 45 | 63 | 85 | ||||
| Força radial máx. | ![]() |
a X/2 | Fque máximo | N | 1200 | 1500 | 1700 | 2000 |
| Força axial máx. | ![]() |
Fmachado | N | 1000 | 1500 | 2000 | 3000 | |