Wenzhou Prance Hydraulic Equipment Co., Ltd.
A2F Fixed Displacement Hydraulic Motor
The A2F product is listed as a fixed displacement hydraulic motor. Its family documentation also includes pump operating conditions, making the intended operating mode and rotation an essential part of selection rather than an assumption from the A2F name.
- Fixed displacement hydraulic motor listing
- ISO mounting flange reference
- Radial shaft-load review required
- Technical material includes separate pump and motor conditions
PRANCE HYDRAULIC · PRODUCT SERIES
Axial piston; fixed displacement · Confirm motor operating mode and circuit
The A2F product is listed as a fixed displacement hydraulic motor. Its family documentation also includes pump operating conditions, making the intended operating mode and rotation an essential part of selection rather than an assumption from the A2F name.
Model

Confirm the complete model and approved specification with Prance Hydraulic. Product-series references alone do not establish interchangeability.
Configuration review · Technical documentation · Product selection
Detalles del producto
- Fixed displacement hydraulic motor listing
- ISO mounting flange reference
- Radial shaft-load review required
- Technical material includes separate pump and motor conditions
CATEGORIES: Motor de desplazamiento fijo, Motor de pistón
A2F Features & Application
Fixed displacement hydraulic motor listing
For a fixed displacement, flow and speed remain linked by the selected displacement. Check the actual operating point and efficiency.
ISO mounting flange reference
Check pilot diameter, bolt pattern, shaft engagement or port pattern against the approved installation drawing.
Radial shaft-load review required
Calculate the external radial and axial loads at their actual distance from the mounting face. Bearing type alone is not a load rating.
Technical material includes separate pump and motor conditions
Specify the full MS order code, installation drawing and operating duty so the quotation can identify the proposed configuration.
A2F Specifications
| Series / model | A2F |
|---|---|
| Product type | A2F Fixed Displacement Hydraulic Motor |
| Diseño | Axial piston; fixed displacement |
| Circuit / selection | Confirm motor operating mode and circuit |
| Product role on this page | Hydraulic motor |
| Operating-mode check | Separate motor data from pump data in the family documentation |
A2F Selection & Configuration
The A2F product is listed as a fixed displacement hydraulic motor. Its family documentation also includes pump operating conditions, making the intended operating mode and rotation an essential part of selection rather than an assumption from the A2F name.
For a motor application, use the motor-specific pressure, speed and flow relationships. Do not apply a pump inlet-pressure condition to a motor port. Confirm fluid compatibility and the permissible radial load for the exact shaft and bearing arrangement.

cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits.
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits.
Hydraulic pumps · Hydraulic motors · Hydraulic valves
Send the MS nameplate, operating requirements and installation drawing for a configuration review before quoting.
- Model review — send the full model code or an existing nameplate photograph.
- Interface matching — confirm shaft, mounting flange, rotation and ports.
- Operating conditions — provide flow, pressure, speed, fluid and duty cycle.
- Documentation — request the relevant product data and drawings for your review.

A2F Buying Guide
Use this sequence to prepare the MS configuration for review and quotation.
- Define starting and continuous torque, speed range and duty cycle.
- Specify available flow, work-port pressure difference and return pressure.
- Confirm the displacement setting and required behavior during starting and stopping.
- Check shaft, mounting pilot, flange, port orientation and external loads.
- Review case drainage, replenishment and any displacement control.
- Specify fluid conditions and any independent braking requirement.
- Approve the complete model, operating envelope, drawing and quantity.

Selection, Documentation & Project Support

Selection Support
Learn more →Share your hydraulic circuit, operating point and installation requirements for a configuration discussion.
Flow · Pressure · Speed · Interfaces

Technical Resources
Learn more →Review product documentation, model codes and technical data before finalizing the specification.
Datasheets · Model codes · Drawings

Project Inquiries
Learn more →Send your required model, quantity, application and project requirements to discuss your inquiry.
Product inquiries · Configuration review
Configuration, Quantity & Delivery
Confirm the complete MS code, approved drawing and operating limits. Availability, quantity, documentation and delivery date are confirmed in the quotation.
Discuss Your A2F Application
Send the full model code, operating duty, installation details and quantity.
Request a A2F QuotationA2F Questions Before Ordering
What type of product is the A2F?
A2F Fixed Displacement Hydraulic Motor. Design: Axial piston; fixed displacement. Confirm motor operating mode and circuit. Confirm the complete order code for the offered version.
Can a similar motor replace the A2F?
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits.
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits.
A2F Technical Data & Documents
View A2F catalog data and operating conditions
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits.
Datos técnicos
Inlet Operating Pressure: Pump : Minimum pressure at ports S, A or B: Pabdominales——————0. 08MPa In closed circuits, the feed pressure must be between 0.2MPa and 0.6MPa, depending on pump speed and viscosity of hydraulic fluid. •Motor: Pressure at port A or B: Nominal pressure——————–Pn =35MPa Peak pressure———————Pmáx=40MPa The sum of the pressures at ports A and B must not exceed 7OMPa (individual pressure on either side max 40MPa) •outlet Operating Pressure •Pump: Nominal pressure————–Pn=35MPa Peak pressure————–Pmáx=40MPa Maximum permissible case pressure(at port T): Pabdominales—————0.2MPa •Oil Temperature Range:-25℃~80℃ •Viscosity Range T mín——————————————10mm2/s T máx—————-( for short periods ) 1000mm2/s Optimum Operating Viscosity:—————————16-25mm2/s Fluid Recommendation :40 low-solidifing •Filtration of hydraulic Fluid: Recommended filtration 10um. Coarser filtration of 25 to40um is acceptable,However longer service life is achieved. •Speed Range: No limitation on minimum speed, If high uniformity of rotation is required,nmin should not be less than 50r/min,See table on page 5 for maximum speed. •Mounting position: Arbitrarily Choose, the housing must be filled with oil; •Flow direction:| En el sentido de las agujas del reloj: | En sentido antihorario |
| A a B S a B (Circuito Abierto) | B a A S a A (Circuito Abierto) |
Contraportada:
![]() |
PresssurePort Drain Port Suction | ||
| Cálculo del tamaño | |||
| bomba | Flujo de salida | Q=(Vg×n×ŋv)/1000 | [L/min] |
| Par de entrada | M=0.159×Vg×Δp/ŋMh | [N:m] | |
| Potencia de entrada | P=(Q×Δp)/(60×ŋ)t) | [Kw] | |
| Motor: | Flujo de entrada | Q=(Vg×n)/(1000×ŋv) | [L/min] |
| Velocidad de salida | n=(Q×1000×ŋv)/Vg | [r/min] | |
| Par de salida | M=0.159×Vg×Δp×ŋMh | [Nm] | |
| Potencia de salida | P=(Q×Δp×ŋt)/60 | [Kw] | |
| Vg = desplazamiento geométrico máximo | [ml/r] | ||
| M=par de torsión | [N.m] | ||
| Δp=presión diferencial | [MPa] | ||
| n=velocidad | [r/min] | ||
| ηv=eficiencia volumétrica | |||
| ηm=eficiencia mecánico-hidráulica | |||
| ηt=eficiencia general | |||
| Used for close system pump. /motor | sistema | 10~160 | 200~500 | ||
| 1.A,B Thread | ![]() |
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits | ![]() |
1. Brida A, B | |
| cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits | ![]() |
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits | ![]() |
![]() |
|
| cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits | cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits | ![]() |
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits | ![]() |
Brida B.S |
| cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits | ![]() |
![]() |
|||
Datos técnicos Valores teóricos, sin considerar η m y ηV, Valores redondeados.
| Tamaño | 10 | 12 | 23 | 28 | 45 | 55 | 63 | 80 | 107 | 125 | 160 | 200 | 250 | 355 | 500 | ||
| Desplazamiento Vg(ml/r) | 9.4 | 11.6 | 22.7 | 28.1 | 44.3 | 54.8 | 63 | 80 | 107 | 125 | 160 | 200 | 250 | 355 | 500 | ||
| cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits | Circuito cerrado | 7500 | 6000 | 5600 | 4750 | 4500 | 3750 | 4000 | 3350 | 3000 | 3150 | 2650 | 2500 | 2500 | 2240 | 2000 | |
| cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits | 0.09 | 4700 | 3750 | 3750 | 2800 | 2850 | 2360 | 2550 | 2120 | 1900 | 2120 | 1650 | 1700 | 1400 | 1250 | 1120 | |
| 0.10 | 5000 | 4000 | 4000 | 3000 | 3000 | 2500 | 2700 | 2240 | 2000 | 2240 | 1750 | 1800 | 1500 | 1320 | 1200 | ||
| 0.15 | 6000 | 4900 | 4900 | 3600 | 3550 | 3000 | 3300 | 2750 | 2450 | 2750 | 2100 | 2180 | 1850 | 1650 | 1500 | ||
| Max Flow Q max(I/min) | Circuito cerrado | 71 | 70 | 127 | 133 | 199 | 206 | 253 | 268 | 321 | 394 | 424 | 500 | 625 | 795 | 1000 | |
| cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits | 0.09 | 43 | 42 | 83 | 76 | 122 | 125 | 156 | 165 | 197 | 257 | 256 | 330 | 340 | 430 | 543 | |
| 0.10 | 46 | 45 | 88 | 82 | 129 | 133 | 165 | 174 | 208 | 272 | 272 | 349 | 364 | 455 | 582 | ||
| 0.15 | 55 | 55 | 108 | 98 | 157 | 159 | 202 | 213 | 251 | 333 | 326 | 423 | 449 | 568 | 728 | ||
| Max Power Pmax(Kw) Δp=35MPa | Circuito cerrado | 41 | 41 | 74 | 78 | 116 | 120 | 147 | 156 | 187 | 230 | 247 | 292 | 365 | 454 | 583 | |
| Open Circuit Inlet Pressure (Pabs =MPa) | 0.09 | 25 | 25 | 48 | 44 | 71 | 73 | 91 | 96 | 115 | 150 | 149 | 192 | 198 | 251 | 317 | |
| 0.10 | 27 | 26 | 51 | 48 | 75 | 78 | 96 | 101 | 121 | 159 | 159 | 204 | 212 | 265 | 340 | ||
| 0.15 | 32 | 32 | 63 | 57 | 92 | 93 | 118 | 124 | 148 | 194 | 190 | 247 | 262 | 331 | 424 | ||
| Electric Motor Speed n=1450/min | Flow Close Circuit | 13.6 | 16.8 | 32.9 | 40.7 | 64.2 | 79.5 | 91.3 | 116 | 155.2 | 181.2 | 232 | 290 | 363 | 515 | 725 | |
| Q(l/min)Open Circuit | 13.2 | 16.3 | 31.9 | 39.5 | 62.3 | 77.1 | 88.6 | 112.5 | 150.5 | 175.8 | 225 | 281 | 352 | 499 | 703 | ||
| P(Kw) Close Δp=35MPa Open | 7.9 | 9.8 | 19.2 | 23.7 | 27.4 | 46 | 53 | 67.7 | 90 | 106 | 135 | 169 | 212 | 300 | 423 | ||
| 7.7 | 9.5 | 18.6 | 23 | 36.3 | 45 | 51.7 | 66 | 88 | 1.3 | 131 | 169 | 212 | 300 | 423 | |||
| Par (N·m) | Δp= 10MPa | 15 | 18 | 36 | 44.7 | 70 | 87 | 100 | 127 | 170 | 199 | 254 | 318 | 398 | 564 | 795 | |
| Δp=35MPa | 52 | 65 | 126 | 156 | 247 | 305 | 351 | 445 | 595 | 696 | 890 | 1113 | 1391 | 1976 | 2783 | ||
| Peso aprox. (kg) | 5 | 5 | 12 | 12 | 23 | 23 | 33 | 33 | 44 | 63 | 63 | 88 | 88 | 138 | 185 | ||
Notas:
1.These values are valid provided there is an absolute pressure at suction inlet Sand when operated on mineral oil. Permissible speed nperm can be determined from the nomograph. In motor operation the permissible speed for closed circuit system and boosted operation are also valid for open circuit system. When suction pressure Pabs > 0. 1MPa, the permissible speed can be increased in open circuits (Self-suction operation). But when suction pressure Pabs < 0.1 MPa, the permissible speed must be reduced.
Example:
Given:size 55,Drive speed 2400r/min
Required:pressure Pabs at the suction Inlet S.
Solution:Line 1 on scale nperm drawn towards size 55 crosses line H at point A .line 11 from point A to point B(open circuit) gives the result:
Pabs > 0.094MPa.
The following are always used together:
1.Scales Pabs,type of circuit and line H.
2.Line H,size scale and nperm.Related Selection Resources
Request a A2F Quotation
Tell us your required configuration, quantity and application.
Datos técnicos
Presión de operación de entrada:
Bomba
Presión mínima en los puertos S, A o B: Pabdominales------------------0. 08MPa En circuitos cerrados, la alimentación
la presión debe estar entre 0,2 MPa y 0,6 MPa, dependiendo de la velocidad de la bomba y de la viscosidad del fluido hidráulico.
• Motor: Presión en el puerto A o B:
Presión nominal--------------------Pn =35 MPa
Presión máxima---------------------Pmáx= 40 MPa
La suma de las presiones en los puertos A y B no debe superar los 70 MPa
(presión individual en cada lado máx. 40 MPa)
• Presión de operación de salida
• Bomba: Presión nominal--------------Pn=35 MPa
Presión máxima--------------Pmáx= 40 MPa
Presión máxima admisible en la carcasa (en el puerto T):
Pabdominales---------------0,2 MPa
•Rango de temperatura del aceite: -25℃~80℃
• Rango de viscosidad
T mín------------------------------------------10 mm2/s
T máx( por períodos cortos ) 1000mm2/s
Viscosidad de operación óptima: 16-25 mm2/s
Recomendación de líquido :40 de baja solidificación
• Filtración de fluido hidráulico:
Filtración recomendada de 10um. Se acepta una filtración más gruesa de 25 a 40um, sin embargo, se logra una vida útil más larga.
•Rango de velocidad:
Sin límite de velocidad mínima.,
Si se requiere una gran uniformidad de rotación,min no debe ser inferior a 50 r/min. Véase la tabla en la página 5 para la velocidad máxima.
• Posición de montaje:
Elegido arbitrariamente, la carcasa debe llenarse de aceite;
• Dirección del flujo:
| En el sentido de las agujas del reloj: | En sentido antihorario |
| A a B S a B (Circuito Abierto) | B a A S a A (Circuito Abierto) |
Contraportada:
![]() |
PressurePort Puerto de drenaje Succión |
||
| Cálculo del tamaño | |||
| bomba | Flujo de salida | Q=(Vg×n×ŋv)/1000 | [L/min] |
| Par de entrada | M=0.159×Vg×Δp/ŋMh | [N:m] | |
| Potencia de entrada | P=(Q×Δp)/(60×ŋ)t) | [Kw] | |
| Motor: | Flujo de entrada | Q=(Vg×n)/(1000×ŋv) | [L/min] |
| Velocidad de salida | n=(Q×1000×ŋv)/Vg | [r/min] | |
| Par de salida | M=0.159×Vg×Δp×ŋMh | [Nm] | |
| Potencia de salida | P=(Q×Δp×ŋt)/60 | [Kw] | |
| Vg = desplazamiento geométrico máximo | [ml/r] | ||
| M=par de torsión | [N.m] | ||
| Δp=presión diferencial | [MPa] | ||
| n=velocidad | [r/min] | ||
| ηv=eficiencia volumétrica | |||
| ηm=eficiencia mecánico-hidráulica | |||
| ηt=eficiencia general | |||
| Utilizado para Cerrar sistema bomba. motor |
sistema | 10~160 | 200~500 | ||
| 1.A,B Hilo |
![]() |
6.A,B Brida |
![]() |
1. Brida A, B | |
| 2. A, B Brida |
![]() |
7.A,B Brida |
![]() |
![]() |
|
| Utilizado para abrir sistema bomba |
3.A,B Brida |
![]() |
5.B,S Gusano espinoso |
![]() |
Brida B.S |
| 4.B,S Hilo |
![]() |
![]() |
|||
Datos técnicos Valores teóricos, sin considerar η m y ηV, Valores redondeados.
| Tamaño | 10 | 12 | 23 | 28 | 45 | 55 | 63 | 80 | 107 | 125 | 160 | 200 | 250 | 355 | 500 | ||
| Desplazamiento Vg(ml/r) | 9.4 | 11.6 | 22.7 | 28.1 | 44.3 | 54.8 | 63 | 80 | 107 | 125 | 160 | 200 | 250 | 355 | 500 | ||
| Velocidad máxima n máx (r/min) |
Circuito cerrado | 7500 | 6000 | 5600 | 4750 | 4500 | 3750 | 4000 | 3350 | 3000 | 3150 | 2650 | 2500 | 2500 | 2240 | 2000 | |
| Circuito abierto Presión de entrada (Pabs=MPa) |
0.09 | 4700 | 3750 | 3750 | 2800 | 2850 | 2360 | 2550 | 2120 | 1900 | 2120 | 1650 | 1700 | 1400 | 1250 | 1120 | |
| 0.10 | 5000 | 4000 | 4000 | 3000 | 3000 | 2500 | 2700 | 2240 | 2000 | 2240 | 1750 | 1800 | 1500 | 1320 | 1200 | ||
| 0.15 | 6000 | 4900 | 4900 | 3600 | 3550 | 3000 | 3300 | 2750 | 2450 | 2750 | 2100 | 2180 | 1850 | 1650 | 1500 | ||
| Flujo máximo Q máx(I/mín) |
Circuito cerrado | 71 | 70 | 127 | 133 | 199 | 206 | 253 | 268 | 321 | 394 | 424 | 500 | 625 | 795 | 1000 | |
| Circuito abierto Presión de entrada (Pabs=MPa) |
0.09 | 43 | 42 | 83 | 76 | 122 | 125 | 156 | 165 | 197 | 257 | 256 | 330 | 340 | 430 | 543 | |
| 0.10 | 46 | 45 | 88 | 82 | 129 | 133 | 165 | 174 | 208 | 272 | 272 | 349 | 364 | 455 | 582 | ||
| 0.15 | 55 | 55 | 108 | 98 | 157 | 159 | 202 | 213 | 251 | 333 | 326 | 423 | 449 | 568 | 728 | ||
| Máximo Poder Pmax(kW) Δp=35MPa |
Circuito cerrado | 41 | 41 | 74 | 78 | 116 | 120 | 147 | 156 | 187 | 230 | 247 | 292 | 365 | 454 | 583 | |
| Circuito abierto Presión de entrada (Pabs = MPa) |
0.09 | 25 | 25 | 48 | 44 | 71 | 73 | 91 | 96 | 115 | 150 | 149 | 192 | 198 | 251 | 317 | |
| 0.10 | 27 | 26 | 51 | 48 | 75 | 78 | 96 | 101 | 121 | 159 | 159 | 204 | 212 | 265 | 340 | ||
| 0.15 | 32 | 32 | 63 | 57 | 92 | 93 | 118 | 124 | 148 | 194 | 190 | 247 | 262 | 331 | 424 | ||
| Motor eléctrico Velocidad n = 1450/min |
Cierre de flujo Circuito |
13.6 | 16.8 | 32.9 | 40.7 | 64.2 | 79.5 | 91.3 | 116 | 155.2 | 181.2 | 232 | 290 | 363 | 515 | 725 | |
| Q(l/min) Abierto Circuito |
13.2 | 16.3 | 31.9 | 39.5 | 62.3 | 77.1 | 88.6 | 112.5 | 150.5 | 175.8 | 225 | 281 | 352 | 499 | 703 | ||
| Cierre P(Kw) Δp=35MPa Abierto |
7.9 | 9.8 | 19.2 | 23.7 | 27.4 | 46 | 53 | 67.7 | 90 | 106 | 135 | 169 | 212 | 300 | 423 | ||
| 7.7 | 9.5 | 18.6 | 23 | 36.3 | 45 | 51.7 | 66 | 88 | 1.3 | 131 | 169 | 212 | 300 | 423 | |||
| Par (N·m) | Δp= 10MPa | 15 | 18 | 36 | 44.7 | 70 | 87 | 100 | 127 | 170 | 199 | 254 | 318 | 398 | 564 | 795 | |
| Δp=35MPa | 52 | 65 | 126 | 156 | 247 | 305 | 351 | 445 | 595 | 696 | 890 | 1113 | 1391 | 1976 | 2783 | ||
| Peso aprox. (kg) | 5 | 5 | 12 | 12 | 23 | 23 | 33 | 33 | 44 | 63 | 63 | 88 | 88 | 138 | 185 | ||
Notas:
1. Estos valores son válidos siempre que exista una presión absoluta en la entrada de succión $Sand cuando se opera con aceite mineral.
La velocidad admisible nperm se puede determinar a partir del nomograma. En operación de motor, la velocidad admisible para el sistema de circuito cerrado y operación con sobrealimentación también es válida para el sistema de circuito abierto. Cuando la presión de aspiración Pabs > 0,1 MPa, la velocidad admisible se puede aumentar en circuitos abiertos (operación con autoaspiración). Pero cuando la presión de aspiración Pabs < 0,1 MPa, la velocidad admisible debe reducirse.

Ejemplo:
Tamaño 55, Velocidad de accionamiento 2400 r/min
Obligatorio: presión Pabs en la entrada de succión S.
Solución: La línea 1 en la escala nperm trazada hacia el tamaño 55 cruza la línea H en el punto A. La línea 11 desde el punto A hasta el punto B (circuito abierto) da como resultado:
Pabs > 0,094 MPa.
Lo siguiente siempre se usa junto:
1.Escalas Pabs, tipo de circuito y línea H.
2.Línea H, escala de tamaño y nperm.