1.Integrated boost pump for boost and pilot oil supply

2.Flow direction changes when the swashplate is moved through the neutral position

3.High-pressure relief valves with integrated boost function

4.Boost-pressure relief valve

5.Optional with pressure cut-off

6.Large variety of controls

وصف تفصيلي

This hydraulic pump is equipped with an integrated boost pump, responsible for providing stable boost pressure and pilot oil supply to ensure reliable system control and normal startup operation. When the swashplate passes through the neutral position, the pump can realize smooth switching of flow direction, avoiding impact and pressure fluctuation. It adopts high-pressure relief valves with integrated boost function, and is fitted with independent boost-pressure relief valve to realize overpressure protection and stable pressure regulation. The pump is optionally configured with pressure cut-off function to set limit pressure according to working conditions and protect components from overload damage. Meanwhile, it supports a large variety of control modes, adaptable to different working scenarios and system matching demands, featuring compact structure, stable running and convenient parameter adjustment.

التقييم وطلب عرض الأسعار

يجب اختيار سلسلة المنتجات هذه بما يتوافق مع الدائرة الهيدروليكية المعتمدة. تأكد من تحديد التدفق أو الإزاحة المطلوبة، والضغط المستمر وأقصى ضغط، وسرعة الدوران، ونظام التحكم، ونوع السائل، وواجهة التركيب قبل إجراء الاختيار النهائي.

المعلومات التي يجب تضمينها في طلب عرض الأسعار الخاص بك

  • الازاحة أو التدفق المطلوب عند سرعة التشغيل
  • ضغط النظام المستمر والقصوي
  • سرعة المحرك، متطلبات التحكم ونوع الدائرة
  • شفة التركيب، العمود، المنافذ، السوائل ومتطلبات الترشيح

الموارد ذات الصلة

اطلب عرض سعر · مركز التنزيل · تصنيع أصلي / تصنيع تصميمي أصلي

اكتب رمزاً

01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22
A10V G / 10 - N C

وحدة كباس محوري

01 Swashplate design, variable,nominal pressure 300 bar, maximum pressure 350 bar A10V

نمط التشغيل

02 مضخة، دائرة مغلقة G

المقاس (NG)

03 الإزاحة الهندسية، انظر "البيانات الفنية" في الصفحة 8 18 28 45 63

جهاز تحكم

18 28 45 63
04 Proportional control

hydraulic

pilot-pressure related, with inlet filtration in P and X1/X2 HD3
mechanical servo واجب منزلي
تحكم آلي، متعلق بالسرعة1) الجهد = 12 فولت - DA1
الجهد = 24 فولت - DA2
Hydraulic control direct operated دي جي
تحكم نسبي، كهربائي with proportional solenoid with inlet filtration in P and X1/X2 الجهد = 12 فولت الحلقة 3
الجهد = 24 فولت الحلقة الرابعة
تحكم بنقطتين، كهربائي with switching solenoid الجهد = 12 فولت إي زي 1
الجهد = 24 فولت EZ2
Electric control, direct operated

two pressure reducing valves (FTDRE)

الجهد = 12 فولت - - ET3
الجهد = 24 فولت - - ET4
Electric pressure controller,

negative control,

with 4/2 directional valve and one pressure reducing valve1)

de-energized, stroking chamber is controlled via X1 الجهد = 24 فولت - ED2
de-energized, stroking chamber is controlled via X2 الجهد = 24 فولت - ED4

قطع الضغط

18 28 45 63
05 Without pressure cut-off (without code)
With pressure cut-off - D

مفتاح الوضع المحايد

18 28 45 63
06 بدون مفتاح وضع حيادي (بدون رمز)
Neutral position switch with DEUTSCH connector (only for HW control) L

محدد الشوط الميكانيكي2)

18 28 45 63
07 بدون محدث شوط ميكانيكي (بدون رمز)
محدد شوط ميكانيكي، قابل للتعديل من الخارج L

منفذ ضغط غرفة الشوط2)

18 28 45 63
08 بدون ضغط منفذ ضغط حجرة (إكس)3, ، X4(without code)
Stroking chamber pressure portX3, ، X4 L

•= available    ○= on request    -= not available     البرنامج المفضل

1) Only possible in combination with pressure cut-off(DA.D..., ED.D...)

2) Not available in combination with DG control device

DA control valve for NG28 ... 63

عالي الدقة واجب منزلي دي جي دا إي بي سهل ET ED
09 بدون صمام تحكم DA - 1
صمام تحكم مزدوج الفعل، إعداد ثابت - - - 2
DA control valve, mechanically adjustable,

with position lever

direction of actuation, counter-clockwise - - - 3L
اتجاه التشغيل، في اتجاه عقارب الساعة - - - ٣ آر
صمام تحكم مزدوج الفعل، إعداد ثابت، فتحات لجهاز التحكم التجريبي - - - - 7
DA control valve, fixed setting, and hydraulic inch valve mounted,control with mineral oil - - - - - - - 8

مسلسل

10 Series 1, index 0 10

اتجاه الدوران

18 28 45 63
11 تمت معاينته على عمود الدوران مع عقارب الساعة R
عكس عقارب الساعة L

مادة مانعة للتسرب

18 28 45 63
12 NBR (nitrile rubber), shaft seal made of FKM (fluoroelastomer) N

عمود الدوران

18 28 45 63
13 عمود مسنن

ANSI B92.1a-1976

لمضخة واحدة S
for combination pump T

شفة التركيب

18 28 45 63
14 SAE J744 ثقبان C

منفذ عامل

15 Port thread: Metric with profile sealing ring sealing according to DIN 3852

Fastening thread at the SAE working port and through drive: Metric according to DIN 13

18 28 45 63
SAE working port A and B, same side left suction port S bottom - 10
SAE working port A and B, same side right suction port S at top

(externally piped up, except for DG)

- 13
Port and working port thread: Metric with profile sealing ring sealing according to DIN 3852

Fastening thread at the through drive: Metric according to DIN 13

18 28 45 63
Threaded port A and B, same side right suction port S bottom - - - 16

Boost pump

18 28 45 63
16 Without integrated boost pump بدون محرك مرور N
with through drive K
Integrated boost pump with and without through drive F

•= available    ○= on request    -= not available     البرنامج المفضل

من خلال القيادة3)

18 28 45 63
17 Without through drive, only for version N and F (position 16) 00
Flange SAE J744 سرّة لعمود مسنن4)
٢-٨٢ (أ) ٥/٨ بوصة 9T 16/32DP 01
٣/٤ بوصة 11 سن 16/32DP - 52
101-2(ب) 7/8 in 13 سن 16/32DP 02
١ بوصة 15T 16/32DP - 04
127-2 (C) 1 1/4 in 14 سن 12/24 دي بي - - - 07

High-pressure relief valve

Setting range Δpعالي الدقة 18 28 45 63
18 High-pressure relief valve

direct operated, fixed setting

250 ... 320 bar without bypass 3
with bypass 5
100 ... 250 bar without bypass - 4
with bypass - 6

Filtration boost circuit/external boost pressure supply

18 28 45 63
19 Filtration in the boost pump suction line S
Filtration in the boost pump pressure line

Ports for external boost circuit filtration (Fe and G (Fa))

- 5) 5) D
External boost pressure supply (on version without integrated boost pump - N, K) E

Connector for solenoids6)

18 28 45 63
20 Without connector (without code), only with purely hydraulic controls
DEUTSCH molded connector

2-pin, DT04-2P

without suppressor diode P
with suppressor diode (only for EZ, DA and ED switching solenoid) Q

Flushing valve

18 28 45 63
21 Without flushing valve (without code)
Flushing valve SAE connection diagram, metric mounting 1
metric threaded ports 3

Standard/special version

22 Standard version بدون رمز
Special version -S

•= متوفر ○= عند الطلب -= غير متوفر     البرنامج المفضل

Notice

▶Note the project planning notes on page 59!

▶In addition to the type code, please specify the relevant technical data when placing your order.

▶Please note that not all type code combinations are available although the individual functions are marked as being available.

3)Specifications for version with integrated boost pump,please contact us for version without boost pump

4)Hub for splined shaft according to ANSI B92.1a-1976(drive shaft allocation according to SAE J744)

5) Pressure filtration is not possible in connection with DA control valve

6) Connectors for other electric components may deviate

البيانات الفنية

حجم غير مقبول 18 28 45 63
Geometric displacement, per revolution
variable pump Vg max

 

سم3 18 28 46 63
boost pump (at p = 20 bar) Vg Sp

 

سم3 5.5 6.1 8.6 14.9
Rotational speed1) maximum at Vجي ماكس nnom min-1 4000 3900 3300 3000
limited maximum2) nmax1 min-1 4850 4200 3550 3250
intermittent maximum3) nmax2 min-1 5200 4500 3800 3500
minimum nmin min-1 500 500 500 500
تدفق at nnom and Vجي ماكس qv لتر/دقيقة 72 109 152 189
Power4) at nnom,  Vجي ماكس and Δp =300 bar P كيلوواط 36 54.6 75.9 94.5
Torque4) with Vجي ماكس and Δp =300 bar M لا شيء جديد 86 134 215 301
Δp =100 bar M لا شيء جديد 28.6 44.6 72 100.3
Rotary stiffness of drive shaft S c kNm/rad 20.28 32.14 53.40 78.37
T c kNm/rad - - 73.80 92.37
Moment of inertia of the rotary group JTW kgm2 0.00093 0.0017 0.0033 0.0056
Maximum angular acceleration5) α rad/s2 6800 5500 4000 3300
Case volume V l 0.45 0.64 0.75 1.1
Weight (without through drive) approx.6) m kg 18 25 27 39

Notice

▶Theoretical values, without efficiency and tolerances;values rounded

▶Operation above the maximum values or below the minimum values may result in a loss of function,a reduced service life or in the destruction of the axial piston unit. Prance recommends testing the loads by means of experiment or calculation /simulation and comparison with the permissible values.

Determining the operating characteristics

تدفق qv=(Vg ∙ n ∙ ηv) / 1000 لتر/دقيقة
Torque M=(Vg ∙ Δp) /(20 ∙ π ∙ ηhm) لا شيء جديد
Power P=(2π ∙ M ∙ n)/60000=(qv ∙ Δp)/(600 ∙ ηt)  كيلوواط

Key

Vg  Displacement per revolution in [cm3]

Δp  Differential pressure [bar]

n   Rotational speed [rpm]

ηv   Volumetric efficiency

ηhm  Hydraulic-mechanical efficiency

ηt   Total efficiency (ηt= ηvhm)

1)The values are applicable:

- for the optimum viscosity range from Vopt = 36 ... 16 mm2/s

- for hydraulic fluid based on mineral oils (for HF hydraulic fluids,observe the technical data in 90225)

2)Valid at half corner power (e.g. at Vg max and pi/2)

3) Valid at Ap = 70 ... 150 bar or Ap < 300 bar and t < 0.1 s

4)Without boost pump

5)The data are valid for values between the minimum required and maximum permissible rotational speed.

Valid for external excitation (e. g. diesel engine 2 to 8 times rotary frequency; cardan shaft twice the rotary frequency).

The limit value is only valid for a single pump.

The load capacity of the connection parts must be considered.

6)Weight may vary by equipment.

Permissible radial and axial loading of the drive shaft

حجم غير مقبول 18 28 28 45 45 63 63
عمود الدوران in 7/8 1 1 1/4 1 1 1/4 1 1/4 1 3/8
Maximum radial

force at distance a

(to the shaft collar)

Fq الحد الأقصى N 1300 2500 2500 3600 3600 5000 5000
a mm 16.5 17.5 17.5 17.5 17.5 17.5 17.5
Maximum axial force +Fax max N 973 987 987 1500 1500 2200 2200
-Fax max N 973 987 987 1500 1500 2200 2200

Notice

▶The axial and radial loading generally influence the bearing service life.

▶Special requirements apply in the case of belt drive and cardan shaft. Please contact us.

Permissible input and through-drive torques

حجم غير مقبول 18 28 45 63
Torque at Vجي ماكس and Δp = 300 bar1) M لا شيء جديد 86 134 220 301
Maximum input torque on drive shaft2)
ANSI B92.1a (SAE J744) S ME الحد الأقصى لا شيء جديد 192 314 314 602
in 7/8 1 1 1 1/4
T ME الحد الأقصى لا شيء جديد - 602 602 970
in - 1 1/4 1 1/4 1 3/8
Maximum through-drive torque ME الحد الأقصى لا شيء جديد 112 220 314 439

Distribution of torques

Torque at 1st pump M1
Torque at 2nd pump M2
Torque at 3rd pump M3
Input torque ME=M1+M2+M3
ME < ME max
Through∙drive torque MD=M2+M3
MD < MD max

1) Efficiency not considered

2) For drive shafts free of radial force

A10VG