Closed Loop Variable Displacement Piston Pump AA4VG

1.Integrated auxliay pump for boost and piot oilsupply.

2.Flow direcion changes smoothy when the swashplate is moved through the neutral postion

3.High-pressure relief valves with integated boost function.

4.With adjustable pressure cut-off as standard

5.Through drive for mounting of further pumps up to same nominal size

6.Large variety of controls

Detaillierte Beschreibung

1.Integrated auxiliary pump for boost and pilot oil supply, which integrates the boost and pilot oil supply functions into a single component, effectively simplifying the overall hydraulic system structure, reducing installation space, and ensuring stable and reliable oil supply for both boost and pilot circuits, thus improving the operational stability of the entire equipment.

2.Flow direction changes smoothly when the swashplate is moved through the neutral position. This design avoids sudden pressure fluctuations and impact during flow direction switching, reduces mechanical wear of internal components, extends the service life of the pump, and ensures smooth and steady operation of the hydraulic system during forward and reverse operation.

3.High-pressure relief valves with integrated boost function, which not only play a role in overpressure protection to prevent damage to the system caused by excessive pressure but also integrate the boost function, realizing the integration of multiple functions, reducing the number of independent components, and lowering the system cost and maintenance difficulty.

4.With adjustable pressure cut-off as standard, allowing users to flexibly adjust the pressure cut-off value according to actual working conditions and load requirements, ensuring the pump operates within the safe pressure range, and adapting to different application scenarios to improve the versatility and applicability of the pump.

5.Through drive for mounting of further pumps up to same nominal size, providing a convenient and compact installation solution for expanding the hydraulic system. It enables the installation of additional pumps of the same nominal size without redesigning the drive structure, enhancing the expandability of the system and meeting the needs of large flow or multi-circuit oil supply.

6.Large variety of controls, including manual, hydraulic, electric and other control modes, which can be selected according to the actual control requirements of the equipment, realizing flexible and precise control of the pump, and adapting to different operating environments and control systems.

Auswahl und Preisanfrage

Diese Produktreihe sollte anhand des freigegebenen Hydraulikkreises ausgewählt werden. Bestätigen Sie vor der endgültigen Auswahl den erforderlichen Volumenstrom oder das Verdrängungsvolumen, den Dauer- und Spitzendruck, die Antriebsdrehzahl, die Steuerungsart, das Fluid und die Einbauschnittstelle.

Angaben für Ihre Angebotsanfrage

  • Erforderliches Verdrängungsvolumen oder Förderstrom bei Betriebsdrehzahl
  • Dauerdruck und Spitzendruck des Systems
  • Antriebsgeschwindigkeit, Steuerungsanforderung und Schaltungsart
  • Montageflansch, Welle, Anschlüsse, Fluid- und Filtrationsanforderung

Verwandte Ressourcen

Angebot anfordern · Download-Center · OEM / ODM

Code eingeben

01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22
AA4V G D / 32 - N

Axialkolbeneinheit

01 Swashplate design, variable, nominal pressure 5800 psi (400 bar), maximum pressure 6500 psi (450 bar) AA4V

Betriebsart

02 Pumpe, geschlossener Kreislauf G

Größe (NG)

03 Geometrisches Verdrängungsvolumen, siehe "Technische Daten" auf Seite 8 in3/rev. 1.71 2.44 3.42 4.33 5.49 7.63
cm3/rev. 28 40 56 71 90 125

Steuergerät

28 40 56 71 90 125
04 Ohne Steuergerät NV
Proportionalregelung, hydraulisch Pilot-pressure related p = 87 to 260 psi (6 to 18 bar) HD3
Mechanischer Servo HW
Proportionalregelung, elektrisch U=12V EP3
U=24V EP4
Zweipunktregelung, elektrisch U=12V EZ1
U=24V EZ2
Automatische Steuerung, drehzahlabhängig U=12V DA1
U=24V DA2
Hydraulic control, direct operated DG
Elektrische Steuerung, direktgesteuert,

zwei Druckminderer

U=12V - - ET5
U=24V - - ET6

Druckabschaltung

05 Pressure cut-off (standard) D

Neutralpositionsschalter

06 Ohne Neutralstellungsschalter (ohne Code)
Neutralpositionsschalter (nur für HW-Steuerung) L

Mechanischer Hubbegrenzer

07 Ohne mechanischen Hubbegrenzer (ohne Code)
Mechanischer Hubbegrenzer, extern einstellbar M

Hubkammerdruckanschluss

28 40 56 71 90 125
08 |Without stroking chamber pressure port X3, X4 (without code)
Kolbenstangenseitiger Druckanschluss X3, X4 T

DA-Regelventil

NV HD HW DG DA EP EZ
09 Ohne DA-Steuerventil - 1
DA-Regelventil, Festeinstellung - 2
DA control valve, mechanically adjustable with position lever Betätigungsrichtung, im Uhrzeigersinn - - 3R
Betätigungsrichtung,

gegen den Uhrzeigersinn

- - 3L
DA-Steuerventil, Festwert, Anschlüsse für Vorsteuergerät - - - 7
DA control valve, fixed setting and

brake inch valve mounted, control with brake fluid

auf Mineralölbasis - - - - - - 8

•= available     ○= on request     -= not available       = bevorzugtes Programm

Serie

10 Reihe 3, Index 2 32

Drehrichtung

11 Auf Antriebswelle betrachtet im Uhrzeigersinn R
gegen den Uhrzeigersinn L

Dichtungsmaterial

12 NBR (nitrile rubber), shaft seal in FKM (fluoroelastomer) N

Antriebswelle

28 40 56 71 90 125
13 Kerbwelle

ANSIB92.1a

für eine einzelne Pumpe S
for combination pump - 1st pump _1) _1) _1) T
only for combination pump -2nd pump - - - - U

Montageflansch

28 40 56 71 90 125
14 SAEJ744 2-Loch - - - C
2+4-Loch - - - F

Funktionierender Port

28 40 56 71 90 125
15 SAE working port A and B, top and bottom Absaugstutzen S unten - 52
SAE working port A and B, top and bottom Absauganschluss S oben - - - 53
SAE working port A and B, same side right2) Absaugstutzen S unten - - - - - 60
SAE working port A and B, same side left2) Absaugstutzen S unten - - - - -
SAE working port A and B, same side right2) Absauganschluss S oben - - - - - 63

Boost pump

16 Ohne integrierte Ladedruckpumpe ohne Durchgangsantrieb N
mit Durchtrieb K
Integrierte Ladedruckpumpe mit und ohne Durchtrieb F

Through drives3)

28 40 56 71 90 125
17 Without through drive, versions N and F (no. 16) only 00
SAE-J744-Flansch4) Nabe für Keilwelle
82-2 (A) 5/8 in 9T 16/32DP5) 01
101-2 (B) 7/8 in 13T 16/32DP5) 02
1in 15T 16/32DP5) 04
127-2 (C)6) 1 1/4 in 14T 12/24DP5) - - 07
152-2/4 (D) 13/4 in 13T 8/16DP5) - - - - - 69

•= available    ○= on request    -= not available     = bevorzugtes Programm

 1) Standard for combination pump - 1st pump: Shaft S

2) Only possible without attachment filter

3) Specifications for version with integrated boost pump, please contact us for version without boost pump

4) 2 = 2-hole; 4 = 4-hole

5) Nabe für Passbzw. Kerbverzahnung nach ANSI B92.1a

6) NG90 to 125 with additional 4-hole-flange (127-4)

Hochdruck-Sicherheitsventil

Setting range Δp 28 40 56 71 90 125
18 High pressure relief valve, pilot operated 1450 to 6100 psi

(100 to 420 bar)

mit Bypass - - - 1
High-pressure relief valve, direct operated,

fixed setting

3600 to 6100 psi

(250 to 420 bar)

ohne Bypass - - - 3
mit Bypass - - - 4
1450 to 3600 bar

(100 to 250 bar)

ohne Bypass - - - 5
mit Bypass - - - 6

Filtrationserhöhungskreis/externe Ladedruckversorgung

28 40 56 71 90 125
19 Filtration in der Vorrats- oder Hilfspumpen-Saugleitung S
Filtration in der Vorförderpumpen-Druckleitung

Ports for external boost circuit filtration (Fe und Fa)

D
Mounted cold start valve and ports for external boost circuit filtration - - - - K
Anbaufilter mit Kaltstartventil - F
Attachment filter with cold start valve and visual contamination indicator - P
Attachment filter with cold start valve and electric contamination indicator - B
External boost pressure supply (version without integrated boost pump - NO0, K...) E

Schwenkwinkelsensor

28 40 56 71 90 125
20 Ohne Schwenkwinkelsensor (ohne Code)
Elektrischer Schwenkwinkelsensor7) R

Magnetstecker8)

21 Without connector (without code), only for purely hydraulic control
DEUTSCH molded connector, 2-pin ohne Schutzdiode P
with suppressor diode (only for EZ and DA) Q

Standard / special version

22 Standardversion ohne Code
combined with attachment part or attachment pump -K
Special version -S
combined with attachment part or attachment pump -SK

•= available    ○= on request    -= not available      = bevorzugtes Programm

Notice

▶Note the project planning notes on page 68.

▶In addition to the type code, please specify the relevant technical data when placing your order.

7)Please contact us if the swivel angle sensor is used for control

8) Connectors for other electric components may deviate

Technische Daten

Größe NG 28 40 56 71 90 125
Geometrisches Fördervolumen pro Umdrehung Vg max

 

in3 1.71 2.44 3.42 4.33 5.49 7.63
variable pump cm3 28 40 56 71 90 125
boost pump (at p = 290 psi (20 bar)) Vg Sp

 

in3 0.37 0.52 0.71 1.20 1.20 1.73
cm3 6.1 8.6 11.6 19.6 19.6 28.3
Rotational speed1) maximum at VG-Max nnom U/min 4250 4000 3600 3300 3050 2950
limited, maximum2) nmax1 U/min 4500 4200 3900 3600 3300 3250
intermittent, maximum3) nmax2 U/min 5000 5000 4500 4100 3800 3450
minimum nmin U/min 500 500 500 500 500 500
Fluss at nnom und VG-Max qv gpm 31.4 42.3 53.4 61.8 72.6 94
l/min 119 160 202 234 275 356
Macht4) at nnom,  VG-Max and Δp = 5800 psi P hp 106 143 180 209 245 319
Δp =400 bar P kW 79 107 134 156 183 238
Drehmoment4) at VG-Max and Δp =5800 psi T Ib-ft 131 188 263 333 423 587
Δp =400 bar T Machs gut 178 255 357 452 573 796
Ap =1450 psi T lb-ft 33 47 66 83 105 147
Ap =100 bar T Machs gut 45 64 89 113 143 199
Rotary stiffness of drive shaft S c lb-ft/rad 23159 50892 59595 72871 116609 161010
kNm/rad 31.4 69 80.8 98.8 158.1 218.3
T c lb-ft/rad - - 70068 89171 - 185939
kNm/rad - - 95 120.9 - 252.1
U c lb-ft/rad - 37468 - - 79362 -
kNm/rad - 50.8 - - 107.6 -
Moment of inertia for rotary group JTW lbs-ft2 0.0522 0.0902 0.1566 0.2302 0.3536 0.5505
kgm2 0.0022 0.0038 0.0066 0.0097 0.0149 0.0232
Maximale Winkelbeschleunigung5) α rad/s2 38000 30000 24000 21000 18000 14000
Fallzahl V gal 0.24 0.29 0.40 0.34 0.40 0.55
I 0.9 1.1 1.5 1.3 1.5 2.1
Weight (without through drive) approx. m Ibs 64 68 84 110 132 176
Kg 29 31 38 50 60 80

Notice

▶Theoretical values, without efficiency and tolerances;values rounded

▶Operation above the maximum values or below the minimum values may result in a loss of function, a reduced service life or in the destruction of the axial piston unit. Bosch Rexroth recommend testing the loads by means of experiment or calculation / simulation and comparison with the permissible values.

Bestimmung der Betriebskennlinien

Fluss qv=(Vg ∙ n ∙ ηv) /231 gpm (Vg ∙ n ∙ ηv) / 1000 l/min
Drehmoment T=(Vg ∙ Δp) /(24 ∙ π ∙ ηhm) lb-ft (Vg ∙ Δp) /(24 ∙ π ∙ ηhm) Machs gut
Macht P=(2π ∙ T ∙ n)/33000=(qv ∙ Δp)/(1714 ∙ ηt) HP (2π ∙ M ∙ n)/60000=(qv ∙ Δp∙ ηt)/600 kW

Schlüssel

Vg  Displacement per revolution [in3(cm3)]

Δp  Differential pressure [psi(bar)]

n Drehzahl [U/min]

ηv   Volumetrischer Wirkungsgrad

ηhm  Hydraulisch-mechanischer Wirkungsgrad

ηt   Gesamtwirkungsgrad (ηt= ηvhm)

1)The values are applicable:

- for the optimum viscosity range from Vopt = 170 to 82 SUS(36 to 16 mm2/s)

- for hydraulic fluid based on mineral oils (for HF hydraulic fluids,observe the technical data in 90225)

2)Valid at half corner power (e.g. at VG-Max and pN/2)

3) Valid at Δp = 1000 to 2200 psi (70 to 150 bar) or Δp < 4350 psi(300 bar) and t < 0.1 s

4)Without boost pump

5)The data are valid for values between the minimum required and maximum permissible rotational speed.

Valid for external excitation (e.g. diesel engine 2 to 8 times rotary frequency, cardan shaft twice the rotary frequency).

The limit value is only valid for a single pump.

The load capacity of the connecting parts must be considered.

Zulässige Radial- und Axialkräfte auf die Antriebswelle

▼Splined shaft ANSI B92.1a

Größe NG 28 40 40 56 56 71
Antriebswelle in 1 1 1 1/4 1 1/4 1 3/8 1 1/4
Maximum radial force at distance a(from shaft collar) Fq Max lbf 671 958 766 1073 975 1360
N 2983 4261 3409 4772 4338 6050
a in 0.75 0.75 0.94 0.94 0.94 0.94
mm 19 19 24 24 24 24
Maximum axial force +FAch, Max lbf 350 477 477 654 654 954
N 1557 2120 2120 2910 2910 4242
-FAch, Max lbf 94 198 198 355 355 620
N 417 880 880 1490 1490 2758
Größe NG 71 90 90 125 125
Antriebswelle in 1 3/8 1 1/4 1 3/4 1 3/4 2
Maximum radial force at distance a(from shaft collar) Fq Max lbf 1236 1724 1232 1711 1497
N 550 7670 5478 7609 6658
a in 0.94 0.94 1.32 1.32 1.57
mm 24 24 33.5 33.5 40
Maximum axial force +FAch, Max lbf 954 973 973 1361 1361
N 4242 4330 4330 6053 6053
-FAch, Max lbf 620 600 600 797 797
N 2758 2670 2670 3547 3547

Notice

▶The axial and radial forces generally influence the service life of the bearings.

▶Special requirements apply in the case of belt drive and cardan shaft. Please contact u

Größe NG 28 40 56 71 90 125
Torque at Vg max and Δp = 5800 psi1) T lb-ft 131 188 263 333 423 587
Δp = 400 bar1) T Machs gut 178 255 357 452 573 796
Maximum input torque

at drive shaft2)

ANSI B92.1a (SAE J744)

S TE Max lb-ft 232 444 444 444 1210 1210
Machs gut 314 602 602 602 1640 1640
in 1 1 1/4 1 1/4 1 1/4 1 3/4 1 3/4
T TE Max lb-ft - - 715 715 - 1969
Machs gut - - 970 970 - 2670
in - - 1 3/8 1 3/8 - 2
U3) TE Max lb-ft - 232 - - 444 -
Machs gut - 314 - - 602 -
in - 1 - - 1 1/4 -
Maximum through-drive torque4) TD Max lb-ft 170 232 384 487 606 819
Machs gut 231 314 521 660 822 1110

Distribution of torques

Torque at 1st pump T1
Torque at 2nd pump T2
Torque at 3rd pump T3
Input torque TE=T1+T2+T3
TE < TE max
Through∙drive torque TD=T2+T3
TD < TD max

1) Efficiency not considered

2) For drive shafts free of radial force

3) Shaft "U" is only permitted as drive shaft on the 2nd pump on a combination pump of the same size.

4)Note maximum input torque for shaft S!