AA4VG Closed Circuit Variable Piston Pump

The AA4VG pump is offered for closed-circuit hydrostatic drives with integrated auxiliary oil supply. Its AA4VG code and interface data must be checked independently when comparing an A4VG configuration, even where nominal displacement appears similar.

  • Integrated auxiliary supply
  • Flow reverses through neutral
  • Adjustable pressure cut-off
  • Through-drive configuration requires matching
HOME › Hydraulikpumpen › AA4VG

PRANCE HYDRAULIC · PRODUCT SERIES

AA4VG Closed Circuit Variable Piston Pump

Axial piston; variable swashplate · Closed circuit

The AA4VG pump is offered for closed-circuit hydrostatic drives with integrated auxiliary oil supply. Its AA4VG code and interface data must be checked independently when comparing an A4VG configuration, even where nominal displacement appears similar.

Model

✓AA4VG original product photograph
AA4VGAxial piston; variable swashplate
Request a QuotationTechnische Daten & Datenblatt anzeigen

Confirm the complete model and approved specification with Prance Hydraulic. Product-series references alone do not establish interchangeability.

Configuration review · Technical documentation · Product selection

Produktdetails

  • Integrated auxiliary supply
  • Flow reverses through neutral
  • Adjustable pressure cut-off
  • Through-drive configuration requires matching

CATEGORIES: Kolbenpumpe, Verstellpumpe

AA4VG Features & Application

Integrated auxiliary supply

Account for pilot or replenishment demand and the relevant pressure limits. Include filtration and the return or drain route in the circuit review.

Flow reverses through neutral

Review combined drive torque and simultaneous demand, including any additional pump connected to the drive.

Adjustable pressure cut-off

Keep continuous, intermittent and peak conditions separate. Use the row for the selected size and configuration.

Through-drive configuration requires matching

Review combined drive torque and simultaneous demand, including any additional pump connected to the drive.

AA4VG Specifications

Series / modelAA4VG
Product typeAA4VG Closed Circuit Variable Piston Pump
DesignAxial piston; variable swashplate
Circuit / selectionClosed circuit
Published nominal sizes28, 40, 56, 71, 90 and 125
SchaltkreisClosed circuit; verify charge and control requirements

AA4VG Selection & Configuration

The AA4VG pump is offered for closed-circuit hydrostatic drives with integrated auxiliary oil supply. Its AA4VG code and interface data must be checked independently when comparing an A4VG configuration, even where nominal displacement appears similar.

Provide the complete machine loop, charge requirements and control specification. Confirm shaft and port standards, pressure cut-off settings and the torque capacity of any through-drive assembly before approving a replacement.

AA4VG original product view

cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits.
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits.

Hydraulic pumps · Hydraulic motors · Hydraulic valves

Send the MS nameplate, operating requirements and installation drawing for a configuration review before quoting.

  • Model review — send the full model code or an existing nameplate photograph.
  • Interface matching — confirm shaft, mounting flange, rotation and ports.
  • Operating conditions — provide flow, pressure, speed, fluid and duty cycle.
  • Documentation — request the relevant product data and drawings for your review.
Prance workshop with a row of production equipment

AA4VG Buying Guide

Use this sequence to prepare the AA4VG configuration for review and quotation.

  1. Define required flow at the actual drive speed and continuous pressure.
  2. Identify peak pressure, duration and the work cycle.
  3. Confirm the selected displacement control and any auxiliary-drive requirement.
  4. Match rotation viewed from the shaft end, shaft, flange and ports.
  5. Review inlet conditions, drain routing and the installation envelope.
  6. Confirm fluid, viscosity, temperature, filtration and seals.
  7. Approve the complete model, control, drawing, quantity and delivery terms.
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits

Selection, Documentation & Project Support

Prance technical team image from its company website

Selection Support

Learn more →

Share your hydraulic circuit, operating point and installation requirements for a configuration discussion.


Flow · Pressure · Speed · Interfaces
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits

Technical Resources

Learn more →

Review product documentation, model codes and technical data before finalizing the specification.


Datasheets · Model codes · Drawings
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits

Project Inquiries

Learn more →

Send your required model, quantity, application and project requirements to discuss your inquiry.


Product inquiries · Configuration review

Configuration, Quantity & Delivery

Confirm the complete MS code, approved drawing and operating limits. Availability, quantity, documentation and delivery date are confirmed in the quotation.

Discuss Your AA4VG Application

Send the full model code, operating duty, installation details and quantity.

Request a AA4VG Quotation

AA4VG Questions Before Ordering

What type of product is the AA4VG?

AA4VG Closed Circuit Variable Piston Pump. Design: Axial piston; variable swashplate. Closed circuit. Confirm the complete order code for the offered version.

Can a similar pump replace the AA4VG?

cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits.

cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits

Define required flow at the actual drive speed and continuous pressure. Identify peak pressure, duration and the work cycle. Attach the nameplate, complete order code, installation drawing and required quantity.

AA4VG Technical Data & Documents

View AA4VG catalog data and operating conditions

cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits.

Technische Daten

Größe NG 28 40 56 71 90 125
Geometrisches Fördervolumen pro Umdrehung VGroßmutterx   in3 1.71 2.44 3.42 4.33 5.49 7.63
Verstellpumpe cm3 28 40 56 71 90 125
Hilfspumpe (bei p = 290 psi (20 bar)) Vg Sp   in3 0.37 0.52 0.71 1.20 1.20 1.73
cm3 6.1 8.6 11.6 19.6 19.6 28.3
Drehzahl1) Maximum bei VG-Max nnom U/min 4250 4000 3600 3300 3050 2950
limitiert, maximal2) nmax1 U/min 4500 4200 3900 3600 3300 3250
intermittierend, maximal3) nmax2 U/min 5000 5000 4500 4100 3800 3450
Minimum nmin. U/min 500 500 500 500 500 500
Fluss bei nnom und VG-Max qv gpm 31.4 42.3 53.4 61.8 72.6 94
l/min 119 160 202 234 275 356
Macht4) bei nnom, VG-Max und Δp = 5800 psi P PS 106 143 180 209 245 319
Δp = 400 bar P kW 79 107 134 156 183 238
Drehmoment4) bei VG-Max und Δp = 5800 psi T Pfund-Fuß 131 188 263 333 423 587
Δp = 400 bar T Machs gut 178 255 357 452 573 796
Ap = 1450 psi T Pound-Feet 33 47 66 83 105 147
Ap = 100 bar T Machs gut 45 64 89 113 143 199
Verdrehsteifigkeit der Antriebswelle S c Pfund-Fuß pro Radian 23159 50892 59595 72871 116609 161010
kNm/rad 31.4 69 80.8 98.8 158.1 218.3
T c Pfund-Fuß pro Radian – – 70068 89171 – 185939
kNm/rad – – 95 120.9 – 252.1
U c Pfund-Fuß pro Radian – 37468 – – 79362 –
kNm/rad – 50.8 – – 107.6 –
Trägheitsmoment der Drehgruppe JTW Pfund-Fuß2 0.0522 0.0902 0.1566 0.2302 0.3536 0.5505
kgm2 0.0022 0.0038 0.0066 0.0097 0.0149 0.0232
Maximale Winkelbeschleunigung5) α rad/s2 38000 30000 24000 21000 18000 14000
Fallzahl V Mädel 0.24 0.29 0.40 0.34 0.40 0.55
I 0.9 1.1 1.5 1.3 1.5 2.1
Gewicht (ohne Durchtrieb) ca. m Ibs 64 68 84 110 132 176
Kg 29 31 38 50 60 80

Hinweis

▶Theoretical values, without efficiency and tolerances;values rounded ▶Operation above the maximum values or below the minimum values may result in a loss of function,a reduced service life or in the destruction of the axial piston unit. Prance recommends testing the loads by means of experiment or calculation /simulation and comparison with the permissible values.

Bestimmung der Betriebskennlinien

Schlüssel

Vg  Verdrängung pro Umdrehung [in3(cm3)] Δp  Differential pressure [psi(bar)] n   Rotational speed [rpm] ηv   Volumetric efficiency ηhm  Hydraulic-mechanical efficiency ηt   Gesamtwirkungsgrad (ηt= ηv*ηhm) 1)The values are applicable: – for the optimum viscosity range from Vopt = 170 to 82 SUS(36 to 16 mm2/s) – for hydraulic fluid based on mineral oils (for HF hydraulic fluids,observe the technical data in 90225) 2)Valid at half corner power (e.g. at VG-Max und pN/2) 3) Valid at Δp = 1000 to 2200 psi (70 to 150 bar) or Δp < 4350 psi(300 bar) and t < 0.1 s 4)Without boost pump 5)The data are valid for values between the minimum required and maximum permissible rotational speed. Valid for external excitation (e.g. diesel engine 2 to 8 times rotary frequency, cardan shaft twice the rotary frequency). The limit value is only valid for a single pump. The load capacity of the connecting parts must be considered.

Zulässige Radial- und Axialkräfte auf die Antriebswelle

▼Keilwelle ANSI B92.1a
Größe NG 28 40 40 56 56 71
Antriebswelle in 1 1 1 1/4 1 1/4 1 3/8 1 1/4
Maximale Radialkraft im Abstand a (vom Wellenbund) cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits Fq Max lbf 671 958 766 1073 975 1360
N 2983 4261 3409 4772 4338 6050
a in 0.75 0.75 0.94 0.94 0.94 0.94
mm 19 19 24 24 24 24
Maximale Axialkraft cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits +FAch, Max lbf 350 477 477 654 654 954
N 1557 2120 2120 2910 2910 4242
-FAch, Max lbf 94 198 198 355 355 620
N 417 880 880 1490 1490 2758
Größe NG 71 90 90 125 125
Antriebswelle in 1 3/8 1 1/4 1 3/4 1 3/4 2
Maximale Radialkraft im Abstand a (vom Wellenbund) cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits Fq Max lbf 1236 1724 1232 1711 1497
N 550 7670 5478 7609 6658
a in 0.94 0.94 1.32 1.32 1.57
mm 24 24 33.5 33.5 40
Maximale Axialkraft cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits +FAch, Max lbf 954 973 973 1361 1361
N 4242 4330 4330 6053 6053
-FAch, Max lbf 620 600 600 797 797
N 2758 2670 2670 3547 3547

Hinweis

▶The axial and radial forces generally influence the service life of the bearings. ▶Special requirements apply in the case of belt drive and cardan shaft. Please contact u
Größe NG 28 40 56 71 90 125
Drehmoment bei Vg max und Δp = 5800 psi1) T Pound-Feet 131 188 263 333 423 587
Δp = 400 bar1) T Machs gut 178 255 357 452 573 796
Maximum input torque at drive shaft2) ANSI B92.1a (SAE J744) S TE Max Pound-Feet 232 444 444 444 1210 1210
Machs gut 314 602 602 602 1640 1640
in 1 1 1/4 1 1/4 1 1/4 1 3/4 1 3/4
T TE Max Pound-Feet – – 715 715 – 1969
Machs gut – – 970 970 – 2670
in – – 1 3/8 1 3/8 – 2
U3) TE Max Pound-Feet – 232 – – 444 –
Machs gut – 314 – – 602 –
in – 1 – – 1 1/4 –
Maximales Durchtriebsdrehmoment4) TD Max Pound-Feet 170 232 384 487 606 819
Machs gut 231 314 521 660 822 1110

Drehmomentverteilung

cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits
Eingangsdrehmoment TE=T1+T2+T3
TE < TE max
Durchtriebsdrehmoment TD=T2+T3
TD < TD max
1) Efficiency not considered 2) For drive shafts free of radial force 3) Shaft “U” is only permitted as drive shaft on the 2nd pump on a combination pump of the same size. 4)Note maximum input torque for shaft S!

Request a AA4VG Quotation

Tell us your required configuration, quantity and application.

Kontaktformular-Demo
AA4VG original product photograph

Code eingeben

01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22
AA4V G D / 32 - N

Axialkolbeneinheit

01 Schrägscheibenbauweise, verstellbar, Nenndruck 5800 psi (400 bar), Maximaldruck 6500 psi (450 bar) AA4V

Betriebsart

02 Pumpe, geschlossener Kreislauf G

Größe (NG)

03 Geometrisches Verdrängungsvolumen, siehe "Technische Daten" auf Seite 8 in3/rev. 1.71 2.44 3.42 4.33 5.49 7.63
cm³/Umdrehung. 28 40 56 71 90 125

Steuergerät

28 40 56 71 90 125
04 Ohne Steuergerät ● ● ● ● ● ● NV
Proportionalregelung, hydraulisch Pilotdruckabhängig p = 87 bis 260 psi (6 bis 18 bar) ○ ○ ● ● ● ● HD3
Mechanischer Servo ● ● ● ● ● ● HW
Proportionalregelung, elektrisch U=12V ● ● ● ● ● ● EP3
U=24V ● ● ● ● ● ● EP4
Zweipunktregelung, elektrisch U=12V ● ● ● ● ● ● EZ1
U=24V ● ● ● ● ● ● EZ2
Automatische Steuerung, drehzahlabhängig U=12V ● ● ● ● ● ● DA1
U=24V ● ● ● ● ● ● DA2
Hydraulische Steuerung, direktgesteuert ○ ○ ● ● ● ● DG
Elektrische Steuerung, direktgesteuert,

zwei Druckminderer

U=12V ● ● ● ● - - ET5
U=24V ● ● ● ● - - ET6

Druckabschaltung

05 Druckabschaltung (Standard) D

Neutralpositionsschalter

06 Ohne Neutralstellungsschalter (ohne Code) ●
Neutralpositionsschalter (nur für HW-Steuerung) ● L

Mechanischer Hubbegrenzer

07 Ohne mechanischen Hubbegrenzer (ohne Code) ●
Mechanischer Hubbegrenzer, extern einstellbar ● M

Hubkammerdruckanschluss

28 40 56 71 90 125
08 Ohne Hub Steuerkammerdruckanschluss X3, X4 (ohne Code) ● ● ● ● ● ●
Kolbenstangenseitiger Druckanschluss X3, X4 ○ ○ ● ● ● ● T

DA-Regelventil

NV HD HW DG DA EP EZ
09 Ohne DA-Steuerventil ● ● ● ● - ● ● 1
DA-Regelventil, Festeinstellung ● ● ● ● ● - 2
DA-Steuerventil, mechanisch verstellbar mit Verstellhebel Betätigungsrichtung, im Uhrzeigersinn - ● ● ● ● ● - 3R
Betätigungsrichtung,

gegen den Uhrzeigersinn

- ● ● ● ● ● - 3L
DA-Steuerventil, Festwert, Anschlüsse für Vorsteuergerät - ○ ○ - ○ ○ - 7
DA-Regelventil, Festeinstellung und

Bremszollventil montiert, Steuerung mit Bremsflüssigkeit

auf Mineralölbasis - - - - ● - - 8

• = verfügbar ○ = auf Anfrage - = nicht verfügbar       = bevorzugtes Programm

Serie

10 Reihe 3, Index 2 32

Drehrichtung

11 Auf Antriebswelle betrachtet im Uhrzeigersinn R
gegen den Uhrzeigersinn L

Dichtungsmaterial

12 NBR (Nitrilkautschuk), Wellendichtring aus FKM (Fluorkautschuk) N

Antriebswelle

28 40 56 71 90 125
13 Kerbwelle

ANSIB92.1a

für eine einzelne Pumpe ● ● ● ● ● ● S
für Kombipumpe - 1. Pumpe _1) _1) ● ● _1) ● T
nur für Kombinationspumpe – 2. Pumpe - ● - - ● - U

Montageflansch

28 40 56 71 90 125
14 SAEJ744 2-Loch ● ● ● - - - C
2+4-Loch - - - ● ● ● F

Funktionierender Port

28 40 56 71 90 125
15 SAE-Arbeitsanschluss A und B, oben und unten Absaugstutzen S unten - ● ● ● ● ● 52
SAE-Arbeitsanschluss A und B, oben und unten Absauganschluss S oben - ○ ● - - ○ 53
SAE-Arbeitsanschluss A und B, beide auf der rechten Seite2) Absaugstutzen S unten ● - - - - - 60
SAE-Arbeitsanschluss A und B, gleiche Seite links2) Absaugstutzen S unten - - - ● - -
SAE-Arbeitsanschluss A und B, beide auf der rechten Seite2) Absauganschluss S oben - - - - - ○ 63

Verstärkung Pumpe

16 Ohne integrierte Ladedruckpumpe ohne Durchgangsantrieb N
mit Durchtrieb K
Integrierte Ladedruckpumpe mit und ohne Durchtrieb F

Durchsuchungsbefehle3)

28 40 56 71 90 125
17 Ohne Durchtrieb, Versionen N und F (Nr. 16) allein ● ● ● ● ● ● 00
SAE-J744-Flansch4) Nabe für Keilwelle
82-2 (A) 5/8 in 9T 16/32DP5) ● ● ● ● ● ● 01
101-2 (B) 7/8 in 13T 16/32DP5) ● ● ● ● ● ● 02
1 in 15T 16/32DP5) ● ● ● ● ● ● 04
127-2 (C)6) 1 1/4 in 14T 12/24DP5) - - ● ● ● ● 07
152-2/4 (D) 13/4 in 13T 8/16DP5) - - - - - ● 69

• = verfügbar ○ = auf Anfrage - = nicht verfügbar     = bevorzugtes Programm

 1) Standard für Kombinationspumpe – 1. Pumpe: Welle S

2) Nur ohne Anhangsfilter möglich

3) Spezifikationen für die Version mit integrierter Booster-Pumpe, bitte kontaktieren Sie uns für die Version ohne Booster-Pumpe

4) 2 = 2-Loch; 4 = 4-Loch

5) Nabe für Passbzw. Kerbverzahnung nach ANSI B92.1a

6) NG90 bis 125 mit zusätzlichem 4-Loch-Flansch (127-4)

Hochdruck-Sicherheitsventil

Einstellbereich Δp 28 40 56 71 90 125
18 Vorseuergetriebenes Hochdruck-Sicherheitsventil 1450 bis 6100 psi

(100 bis 420 bar)

mit Bypass - - - ● ● ● 1
Druckbegrenzungsventil, direktgesteuert,

fester Wert

3600 bis 6100 psi

(250 bis 420 bar)

ohne Bypass ● ● ● - - - 3
mit Bypass ● ● ● - - - 4
1450 bis 3600 bar

(100 bis 250 bar)

ohne Bypass ● ● ● - - - 5
mit Bypass ● ● ● - - - 6

Filtrationserhöhungskreis/externe Ladedruckversorgung

28 40 56 71 90 125
19 Filtration in der Vorrats- oder Hilfspumpen-Saugleitung ● ● ● ● ● ● S
Filtration in der Vorförderpumpen-Druckleitung

Anschlüsse für externe Boost-Schaltungsfilterunge und Fa)

● ● ● ● ● ● D
Montiertes Kaltstartventil und Anschlüsse für die externe Ladedruckkreislauffiltrierung - ● ● - - - K
Anbaufilter mit Kaltstartventil - ● ● ● ● ● F
Anbaufü过滤器 mit Kaltstartventil und optischer Verschmutzungsanzeige - ● ● ● ● ● P
Anbaufilter mit Kaltstartventil und elektrischer Verschmutzungsanzeige - ● ● ● ● ● B
Externe Ladedruckversorgung (Ausführung ohne integrierte Ladedruckpumpe - NO0, K...) ● ● ● ● ● ● E

Schwenkwinkelsensor

28 40 56 71 90 125
20 Ohne Schwenkwinkelsensor (ohne Code) ● ● ● ● ● ●
Elektrischer Schwenkwinkelsensor7) ○ ○ ● ○ ○ ○ R

Magnetstecker8)

21 Ohne Steckverbinder (ohne Code), nur für rein hydraulische Steuerung ●
DEUTSCH-Steckverbinder, 2-polig ohne Schutzdiode ● P
mit Löschdiode (nur für EZ und DA) ● Q

Standard- / Sonderversion

22 Standardversion ohne Code
kombiniert mit Anbauteil oder Anbaupumpe -K
Sonderversion -S
kombiniert mit Anbauteil oder Anbaupumpe -SK

• = verfügbar ○ = auf Anfrage - = nicht verfügbar      = bevorzugtes Programm

Hinweis

▶ Beachten Sie die Projekplanungshinweise auf Seite 68.

▶Bitte geben Sie bei Ihrer Bestellung zusätzlich zum Typencode die relevanten technischen Daten an.

Bitte kontaktieren Sie uns, wenn der Schwenkwinkelsensor zur Steuerung verwendet wird.

8) Anschlüsse für andere elektrische Komponenten können abweichen

Technische Daten

Größe NG 28 40 56 71 90 125
Geometrisches Fördervolumen pro Umdrehung VGroßmutterx

 

in3 1.71 2.44 3.42 4.33 5.49 7.63
Verstellpumpe cm3 28 40 56 71 90 125
Hilfspumpe (bei p = 290 psi (20 bar)) Vg Sp

 

in3 0.37 0.52 0.71 1.20 1.20 1.73
cm3 6.1 8.6 11.6 19.6 19.6 28.3
Drehzahl1) Maximum bei VG-Max nnom U/min 4250 4000 3600 3300 3050 2950
limitiert, maximal2) nmax1 U/min 4500 4200 3900 3600 3300 3250
intermittierend, maximal3) nmax2 U/min 5000 5000 4500 4100 3800 3450
Minimum nmin. U/min 500 500 500 500 500 500
Fluss bei nnom und VG-Max qv gpm 31.4 42.3 53.4 61.8 72.6 94
l/min 119 160 202 234 275 356
Macht4) bei nnom, VG-Max und Δp = 5800 psi P PS 106 143 180 209 245 319
Δp = 400 bar P kW 79 107 134 156 183 238
Drehmoment4) bei VG-Max und Δp = 5800 psi T Pfund-Fuß 131 188 263 333 423 587
Δp = 400 bar T Machs gut 178 255 357 452 573 796
Ap = 1450 psi T Pound-Feet 33 47 66 83 105 147
Ap = 100 bar T Machs gut 45 64 89 113 143 199
Verdrehsteifigkeit der Antriebswelle S c Pfund-Fuß pro Radian 23159 50892 59595 72871 116609 161010
kNm/rad 31.4 69 80.8 98.8 158.1 218.3
T c Pfund-Fuß pro Radian - - 70068 89171 - 185939
kNm/rad - - 95 120.9 - 252.1
U c Pfund-Fuß pro Radian - 37468 - - 79362 -
kNm/rad - 50.8 - - 107.6 -
Trägheitsmoment der Drehgruppe JTW Pfund-Fuß2 0.0522 0.0902 0.1566 0.2302 0.3536 0.5505
kgm2 0.0022 0.0038 0.0066 0.0097 0.0149 0.0232
Maximale Winkelbeschleunigung5) α rad/s2 38000 30000 24000 21000 18000 14000
Fallzahl V Mädel 0.24 0.29 0.40 0.34 0.40 0.55
I 0.9 1.1 1.5 1.3 1.5 2.1
Gewicht (ohne Durchtrieb) ca. m Ibs 64 68 84 110 132 176
Kg 29 31 38 50 60 80

Hinweis

▶ Theoretische Werte, ohne Wirkungsgrad und Toleranzen; Werte gerundet

▶Der Betrieb oberhalb der Maximalwerte oder unterhalb der Minimalwerte kann zum Funktionsverlust, zu einer verkürzten Lebensdauer oder zur Zerstörung der Axialkolbeneinheit führen. Bosch Rexroth empfiehlt, die Belastungen durch Experimente oder Berechnungen / Simulationen zu überprüfen und mit den zulässigen Werten zu vergleichen.

Bestimmung der Betriebskennlinien

Fluss qv=(Vg ∙ n ∙ ηv) /231 gpm (Vg ∙ n ∙ ηv) / 1000 l/min
Drehmoment T=(Vg ∙ Δp) / (24 ∙ π ∙ ηhm) Pound-Feet (Vg ∙ Δp) / (24 ∙ π ∙ ηhm) Machs gut
Macht P=(2π ∙ T ∙ n)/33000=(qv ∙ Δp)/(1714 ∙ ηt) HP (2π ∙ M ∙ n)/60000 = qv ∙ Δp∙ ηt)/600 kW

Schlüssel

Vg  Verdrängung pro Umdrehung [in3(cm3)]

Δp Differenzdruck [psi(bar)]

n Drehzahl [U/min]

ηv   Volumetrischer Wirkungsgrad

ηhm  Hydraulisch-mechanischer Wirkungsgrad

ηt   Gesamtwirkungsgrad (ηt= ηv*ηhm)

Die Werte gelten:

- für den optimalen Viskositätsbereich von Vopt = 170 bis 82 SUS (36 bis 16 mm2/s)

- für Hydraulikflüssigkeiten auf Mineralölbasis (bei HF-Hydraulikflüssigkeiten die technischen Daten in 90225 beachten)

2) Gültig bei halber Eckleistung (z. B. bei VG-Max und pN/2)

3) Gültig bei Δp = 1000 bis 2200 psi (70 bis 150 bar) oder Δp < 4350 psi (300 bar) und t < 0,1 s

4) Ohne Förderpumpe

Die Daten gelten für Werte zwischen der minimal erforderlichen und der maximal zulässigen Drehzahl.

Gültig für Fremderregung (z. B. Dieselmotor 2- bis 8-fache Drehfrequenz, Kardanwelle 2-fache Drehfrequenz).

Der Grenzwert gilt nur für eine einzelne Pumpe.

Die Tragfähigkeit der Verbindungsteile muss berücksichtigt werden.

Zulässige Radial- und Axialkräfte auf die Antriebswelle

▼Keilwelle ANSI B92.1a

Größe NG 28 40 40 56 56 71
Antriebswelle in 1 1 1 1/4 1 1/4 1 3/8 1 1/4
Maximale Radialkraft im Abstand a (vom Wellenbund) Fq Max lbf 671 958 766 1073 975 1360
N 2983 4261 3409 4772 4338 6050
a in 0.75 0.75 0.94 0.94 0.94 0.94
mm 19 19 24 24 24 24
Maximale Axialkraft +FAch, Max lbf 350 477 477 654 654 954
N 1557 2120 2120 2910 2910 4242
-FAch, Max lbf 94 198 198 355 355 620
N 417 880 880 1490 1490 2758
Größe NG 71 90 90 125 125
Antriebswelle in 1 3/8 1 1/4 1 3/4 1 3/4 2
Maximale Radialkraft im Abstand a (vom Wellenbund) Fq Max lbf 1236 1724 1232 1711 1497
N 550 7670 5478 7609 6658
a in 0.94 0.94 1.32 1.32 1.57
mm 24 24 33.5 33.5 40
Maximale Axialkraft +FAch, Max lbf 954 973 973 1361 1361
N 4242 4330 4330 6053 6053
-FAch, Max lbf 620 600 600 797 797
N 2758 2670 2670 3547 3547

Hinweis

Die Axial- und Radialkräfte beeinflussen im Allgemeinen die Lebensdauer der Lager.

▶Bei Riemenantrieb und Kardanwelle gelten besondere Anforderungen. Bitte kontaktieren Sie uns.

Größe NG 28 40 56 71 90 125
Drehmoment bei Vg max und Δp = 5800 psi1) T Pound-Feet 131 188 263 333 423 587
Δp = 400 bar1) T Machs gut 178 255 357 452 573 796
Maximales Eingangsdrehmoment

an der Antriebswelle2)

ANSI B92.1a (SAE J744)

S TE Max Pound-Feet 232 444 444 444 1210 1210
Machs gut 314 602 602 602 1640 1640
in 1 1 1/4 1 1/4 1 1/4 1 3/4 1 3/4
T TE Max Pound-Feet - - 715 715 - 1969
Machs gut - - 970 970 - 2670
in - - 1 3/8 1 3/8 - 2
U3) TE Max Pound-Feet - 232 - - 444 -
Machs gut - 314 - - 602 -
in - 1 - - 1 1/4 -
Maximales Durchtriebsdrehmoment4) TD Max Pound-Feet 170 232 384 487 606 819
Machs gut 231 314 521 660 822 1110

Drehmomentverteilung

Drehmoment an der 1. Pumpe T1
Drehmoment an der 2. Pumpe T2
Drehmoment an der 3. Pumpe T3
Eingangsdrehmoment TE=T1+T2+T3
TE < TE max
Durchtriebsdrehmoment TD=T2+T3
TD < TD max

1) Effizienz nicht berücksichtigt

2) Für radiale kraftfreie Gelenkwellen

3) Welle "U" ist als Antriebswelle nur an der 2. Pumpe einer Kombipumpe gleicher Baugröße zulässig.

4) Maximales Eingangsdrehmoment für Welle S beachten!