Proportional Valve 4WRAE
1.Direct actuated proportional valve for controlling the direction and volume flow of a hydraulic fluid
2.For subplate mounting
3.For the open loop control of both direction and flow of a hydraulic fluid Spring centred control spool
4.Low pressure drop across the control lands
5.Both valve and electronic control from one supplier
Detailed description
Technical data
(for applications outside these parameters, please consult us!)
General
| Nominal size | NS | 6 | 10 | |
| Installation | optional, preferably horizontal | |||
| Storage temperature range | ℃ | -20 to +80 | ||
| Ambient | 4WRA | ℃ | -20 to +70 | |
| temperature range | 4WRAE | ℃ | -20 to +50 | |
| Weight | 4WRA | kg | 2.0 | 6.6 |
| 4WRAE | kg | 2.2 | 6.8 | |
| Hydraulic (measured with HLP46,Θoil= 40 ℃±5 ℃) | ||||
| Max. operating pressure | Ports A, B, P | bar | 315 | |
| Port T | bar | 210 | ||
| Nominal flow qV nom at Δp=10 bar | l/min | 7,15,26 | 30,60 | |
| Max. permissible flow | l/min | 42 (80)1) | 75 (140)1) | |
| Pressure fluid | mineral oil (HL, HLP) to DIN 51524 other pressure fluids on request! |
|||
| Pressure fluid temperature range | ℃ | -20 to +80 (preferably +40 to +50) | ||
| Viscosity range | mm2/s | 20 to 380 (preferably 30 to 46) | ||
| Max. permissible degree of pressure fluid contamination cleanlisness class to ISO 4406 (c) | class 20/18/15 2) | |||
| Hysteresis | % | ≤ 5 | ||
| Reversal error | % | ≤ 1 | ||
| Response sensitivity | % | ≤ 0.5 | ||
1)permissible flow with a dual flow path
2)The cleanliness class stated for the components must be adhered too in hydraulic systems. Effective filtration prevents faults from occurring and at the same time increases the component service life.For the selection of filters see catalogue sheets RE 50070,RE 50076, RE 50081, RE 50086 and RE 50088
Electical
| Nominal size | NS | 6 | 10 | |
| Voltage type | DC | |||
| Command value signa | Voltage input "A1" | V | ±10 | |
| with type WRAE | Current input "F1" | mA | 4 to 20 | |
| Max. current per solenoid | A | 2.5 | ||
| Solenoid coil | Cold value at 20 ℃ | Ω | 2 | |
| resistance | Max. warm value | Ω | 3 | |
| Duty | % | 100 | ||
| Max. coil temperature 1) | ℃ | 150 | ||
| Electrical connections see page 7 |
4WRA | with component plug to DIN EN 175301-803 or ISO 4400 | ||
| plug-in connector to DIN EN 175301-803 or ISO 4400 2) | ||||
| 4WRAE | with component plug to DIN EN 175201-804 | |||
| plug-in connector DIN EN 175201-804 2) | ||||
| Valve protection to EN 60529 | IP65 with mounted and fixed plug-in connector | |||
Control electronics
| For 4WRA | Digital amplifier in Eurocard format 2) | VT-VSPD-1-2X (to RE 30523 - middle of 2006) | |
| Analogue amplifier in Eurocard format 2) | VT-VSPA2-1-2X/... to RE 30110 | ||
| Analogue module amplifier 2) | VT-MSPA2-1-1X to RE 30228 | ||
| For 4WRAE | Analogue command value module | integrated into the valves, see page 8 | |
| VT- SWMA-1-1X/... to RE 29902 | |||
| Analogue command value module | VT-SWMKA-1-1X/... to RE 29903 | ||
| Digital command value card | VT-HACD-1-1X/... to RE 30143 | ||
| Analogue command value card | VT-SWKA-1-1X/... to RE 30255 | ||
| Supply voltage 4WRAE, 4WRA 3) |
Nominal voltage | VDC | 24 |
| Lower limiting value | V | 21 / 22 (4WRA); 19 (4WRAE) |
|
| Upper limiting value | V | 35 | |
| Amplifier current | lmax | A | 1.8 |
| consumption | Max. impulse current | A | 3 |
1) Due to the occurring surface temperature of the solenoid coils, the European Standards DIN EN 563 and DIN EN 982must be taken into account!
2) Separate order
3) With Bosch Rexroth AG control electronics
Note:
For details regarding the environmental simulation test covering EMC (electromagnetic compatibility), climate and mechanical loading see RE 29055-U(declaration regarding environmental compatibility).